{"title":"医学图像编码中的单步和多步图像放大","authors":"M. Khosravi","doi":"10.2174/1574362414666190131105731","DOIUrl":null,"url":null,"abstract":"\n\nSome interpolators cannot be used in an image magnification problem in a freely scalable form.\nFor instance, when we want to magnify an image to a 16-time bigger scale, some interpolators have to do this process in\ntwo steps including two 4-time magnification steps, however, some are able to do it directly.\n\n\n\n For generating data of this study, MATLAB as a simulator has been used. Bi-; Linear (BL) and\nCubic Convolution (CC) interpolators are the two applied re-samplers in the reconstruction of digital images.\n\n\n\n Data shows that the performance of both free-size interpolators (BL and CC) is obviously different in both direct\nand indirect pixel reconstruction.\n\n\n\nThe acquired data shows a less error in the condition of direct interpolation. The relative results of experiments\nare different from the type of core interpolators (BL and CC).\n","PeriodicalId":10868,"journal":{"name":"Current Signal Transduction Therapy","volume":"15 1","pages":"86-87"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2174/1574362414666190131105731","citationCount":"4","resultStr":"{\"title\":\"Single- and Multi-Step Image Enlargement for Medical Image Coding\",\"authors\":\"M. Khosravi\",\"doi\":\"10.2174/1574362414666190131105731\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n\\nSome interpolators cannot be used in an image magnification problem in a freely scalable form.\\nFor instance, when we want to magnify an image to a 16-time bigger scale, some interpolators have to do this process in\\ntwo steps including two 4-time magnification steps, however, some are able to do it directly.\\n\\n\\n\\n For generating data of this study, MATLAB as a simulator has been used. Bi-; Linear (BL) and\\nCubic Convolution (CC) interpolators are the two applied re-samplers in the reconstruction of digital images.\\n\\n\\n\\n Data shows that the performance of both free-size interpolators (BL and CC) is obviously different in both direct\\nand indirect pixel reconstruction.\\n\\n\\n\\nThe acquired data shows a less error in the condition of direct interpolation. The relative results of experiments\\nare different from the type of core interpolators (BL and CC).\\n\",\"PeriodicalId\":10868,\"journal\":{\"name\":\"Current Signal Transduction Therapy\",\"volume\":\"15 1\",\"pages\":\"86-87\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2174/1574362414666190131105731\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Signal Transduction Therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/1574362414666190131105731\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Signal Transduction Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1574362414666190131105731","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Single- and Multi-Step Image Enlargement for Medical Image Coding
Some interpolators cannot be used in an image magnification problem in a freely scalable form.
For instance, when we want to magnify an image to a 16-time bigger scale, some interpolators have to do this process in
two steps including two 4-time magnification steps, however, some are able to do it directly.
For generating data of this study, MATLAB as a simulator has been used. Bi-; Linear (BL) and
Cubic Convolution (CC) interpolators are the two applied re-samplers in the reconstruction of digital images.
Data shows that the performance of both free-size interpolators (BL and CC) is obviously different in both direct
and indirect pixel reconstruction.
The acquired data shows a less error in the condition of direct interpolation. The relative results of experiments
are different from the type of core interpolators (BL and CC).
期刊介绍:
In recent years a breakthrough has occurred in our understanding of the molecular pathomechanisms of human diseases whereby most of our diseases are related to intra and intercellular communication disorders. The concept of signal transduction therapy has got into the front line of modern drug research, and a multidisciplinary approach is being used to identify and treat signaling disorders.
The journal publishes timely in-depth reviews, research article and drug clinical trial studies in the field of signal transduction therapy. Thematic issues are also published to cover selected areas of signal transduction therapy. Coverage of the field includes genomics, proteomics, medicinal chemistry and the relevant diseases involved in signaling e.g. cancer, neurodegenerative and inflammatory diseases. Current Signal Transduction Therapy is an essential journal for all involved in drug design and discovery.