{"title":"经导管冠状动脉球囊肺动脉瓣成形术治疗新生儿完全性室间隔肺闭锁1例","authors":"V. Desabandhu, S. Narayanan, Mohanan S Sajeer","doi":"10.4103/heartindia.heartindia_1_20","DOIUrl":null,"url":null,"abstract":"Pulmonary atresia with intact ventricular septum is a rare cause of cyanosis in a newborn. The prognosis and treatment of the condition depend on the pulmonary anatomy as well as the state of the right ventricle. We present a case where the patient presented with acute desaturation, and we had to do an emergency pulmonary valvotomy, using coronary wires and balloons, as a lifesaving procedure. The saturation improved on the table, and the patient could be discharged from hospital in a stable state. This particular case shows that opening an atretic pulmonary valve is a viable option and coronary wires and balloons can be used for the purpose.","PeriodicalId":32147,"journal":{"name":"Heart India","volume":"8 1","pages":"148 - 150"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transcatheter pulmonary valvuloplasty with coronary balloon for critical pulmonary atresia with intact ventricular septum in a neonate\",\"authors\":\"V. Desabandhu, S. Narayanan, Mohanan S Sajeer\",\"doi\":\"10.4103/heartindia.heartindia_1_20\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pulmonary atresia with intact ventricular septum is a rare cause of cyanosis in a newborn. The prognosis and treatment of the condition depend on the pulmonary anatomy as well as the state of the right ventricle. We present a case where the patient presented with acute desaturation, and we had to do an emergency pulmonary valvotomy, using coronary wires and balloons, as a lifesaving procedure. The saturation improved on the table, and the patient could be discharged from hospital in a stable state. This particular case shows that opening an atretic pulmonary valve is a viable option and coronary wires and balloons can be used for the purpose.\",\"PeriodicalId\":32147,\"journal\":{\"name\":\"Heart India\",\"volume\":\"8 1\",\"pages\":\"148 - 150\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heart India\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/heartindia.heartindia_1_20\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart India","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/heartindia.heartindia_1_20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
Transcatheter pulmonary valvuloplasty with coronary balloon for critical pulmonary atresia with intact ventricular septum in a neonate
Pulmonary atresia with intact ventricular septum is a rare cause of cyanosis in a newborn. The prognosis and treatment of the condition depend on the pulmonary anatomy as well as the state of the right ventricle. We present a case where the patient presented with acute desaturation, and we had to do an emergency pulmonary valvotomy, using coronary wires and balloons, as a lifesaving procedure. The saturation improved on the table, and the patient could be discharged from hospital in a stable state. This particular case shows that opening an atretic pulmonary valve is a viable option and coronary wires and balloons can be used for the purpose.