{"title":"粮食水分测量系统具有鲁棒传递函数,对粮食理化成分的变化具有不变性","authors":"O. Zabolotnyi, V. Zabolotnyi, N. Koshevoy","doi":"10.35633/inmateh-69-36","DOIUrl":null,"url":null,"abstract":"The main task was to receive a robust transfer function for the capacitive grain moisture measurement system. It was estimated how the new transfer function compensates for the type uncertainty and how close it is to the nominal values of moisture content. Dispersions of adequacy and repeatability of the new transfer function, which describe possible variation in the measured moisture values and the correspondence of the new transfer function with the nominal linear transfer function of a moisture meter respectively, were calculated for five chosen substances. It was proved that the new transfer function has lower sensitivity to grain type and better adequacy to the ideal transfer function than the closest analog.","PeriodicalId":44197,"journal":{"name":"INMATEH-Agricultural Engineering","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2023-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"GRAIN MOISTURE MEASUREMENT SYSTEM WITH ROBUST TRANSFER FUNCTION, INVARIANT TO THE CHANGE OF A PHYSICO-CHEMICAL GRAIN COMPOSITION\",\"authors\":\"O. Zabolotnyi, V. Zabolotnyi, N. Koshevoy\",\"doi\":\"10.35633/inmateh-69-36\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main task was to receive a robust transfer function for the capacitive grain moisture measurement system. It was estimated how the new transfer function compensates for the type uncertainty and how close it is to the nominal values of moisture content. Dispersions of adequacy and repeatability of the new transfer function, which describe possible variation in the measured moisture values and the correspondence of the new transfer function with the nominal linear transfer function of a moisture meter respectively, were calculated for five chosen substances. It was proved that the new transfer function has lower sensitivity to grain type and better adequacy to the ideal transfer function than the closest analog.\",\"PeriodicalId\":44197,\"journal\":{\"name\":\"INMATEH-Agricultural Engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-04-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"INMATEH-Agricultural Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35633/inmateh-69-36\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"AGRICULTURAL ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"INMATEH-Agricultural Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35633/inmateh-69-36","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"AGRICULTURAL ENGINEERING","Score":null,"Total":0}
GRAIN MOISTURE MEASUREMENT SYSTEM WITH ROBUST TRANSFER FUNCTION, INVARIANT TO THE CHANGE OF A PHYSICO-CHEMICAL GRAIN COMPOSITION
The main task was to receive a robust transfer function for the capacitive grain moisture measurement system. It was estimated how the new transfer function compensates for the type uncertainty and how close it is to the nominal values of moisture content. Dispersions of adequacy and repeatability of the new transfer function, which describe possible variation in the measured moisture values and the correspondence of the new transfer function with the nominal linear transfer function of a moisture meter respectively, were calculated for five chosen substances. It was proved that the new transfer function has lower sensitivity to grain type and better adequacy to the ideal transfer function than the closest analog.