{"title":"固相萃取(SPE)和高效液相色谱(HPLC)在分析胎牛血清中nesfatin-1中的应用及两种检测技术(DAD和FLD)的比较","authors":"T. Tuzimski, Michał Szubartowski","doi":"10.1556/1326.2022.01076","DOIUrl":null,"url":null,"abstract":"\n In this study, we propose a simple, cost-effective, and sensitive high-performance liquid chromatography with both detection techniques such as diode-array detection and fluorescence detection (HPLC-DAD-FLD) for the determination of nesfatin-1 in fetal bovine serum samples. The limit of detection (LOD) and limit of quantification (LOQ) for nesfatin-1 were set at satisfactory values in the range 0.22–0.35 mg mL−1 and in the range 0.67–1.05 mg mL−1, respectively (at two different wavelengths (DAD) and at four different wavelengths (FLD)). Analyte concentrations were determined as the average value from fetal bovine serum matrix samples. The preliminary results show that the SPE procedure on Isolute Si-TsOH (SCX-3) could be used for further nesfatin-1 analyses in human serum samples. Both the SPE technique, chromatographic analysis with gradient elution mode and detection technique are fast and convenient.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2022-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) and comparison of both detection techniques (DAD and FLD) to analyse nesfatin-1 in fetal bovine serum samples\",\"authors\":\"T. Tuzimski, Michał Szubartowski\",\"doi\":\"10.1556/1326.2022.01076\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n In this study, we propose a simple, cost-effective, and sensitive high-performance liquid chromatography with both detection techniques such as diode-array detection and fluorescence detection (HPLC-DAD-FLD) for the determination of nesfatin-1 in fetal bovine serum samples. The limit of detection (LOD) and limit of quantification (LOQ) for nesfatin-1 were set at satisfactory values in the range 0.22–0.35 mg mL−1 and in the range 0.67–1.05 mg mL−1, respectively (at two different wavelengths (DAD) and at four different wavelengths (FLD)). Analyte concentrations were determined as the average value from fetal bovine serum matrix samples. The preliminary results show that the SPE procedure on Isolute Si-TsOH (SCX-3) could be used for further nesfatin-1 analyses in human serum samples. Both the SPE technique, chromatographic analysis with gradient elution mode and detection technique are fast and convenient.\",\"PeriodicalId\":7130,\"journal\":{\"name\":\"Acta Chromatographica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2022-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Chromatographica\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1556/1326.2022.01076\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2022.01076","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
摘要
在这项研究中,我们提出了一种简单、经济、灵敏的高效液相色谱检测技术,如二极管阵列检测和荧光检测(HPLC-DAD-FLD),用于测定胎牛血清样品中的nesfatin-1。nesfatin-1的检出限(LOD)和定量限(LOQ)分别在0.22 ~ 0.35 mg mL -1和0.67 ~ 1.05 mg mL -1范围内(两种不同波长(DAD)和四种不同波长(FLD))设定在令人满意的值。分析物浓度测定为胎牛血清基质样品的平均值。初步结果表明,固相萃取法可用于进一步分析人血清样品中的脂质-1。固相萃取技术、梯度洗脱色谱分析和检测技术均具有快速方便的特点。
Application of solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) and comparison of both detection techniques (DAD and FLD) to analyse nesfatin-1 in fetal bovine serum samples
In this study, we propose a simple, cost-effective, and sensitive high-performance liquid chromatography with both detection techniques such as diode-array detection and fluorescence detection (HPLC-DAD-FLD) for the determination of nesfatin-1 in fetal bovine serum samples. The limit of detection (LOD) and limit of quantification (LOQ) for nesfatin-1 were set at satisfactory values in the range 0.22–0.35 mg mL−1 and in the range 0.67–1.05 mg mL−1, respectively (at two different wavelengths (DAD) and at four different wavelengths (FLD)). Analyte concentrations were determined as the average value from fetal bovine serum matrix samples. The preliminary results show that the SPE procedure on Isolute Si-TsOH (SCX-3) could be used for further nesfatin-1 analyses in human serum samples. Both the SPE technique, chromatographic analysis with gradient elution mode and detection technique are fast and convenient.
期刊介绍:
Acta Chromatographica
Open Access
Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.