气相色谱系统的柱上低温聚焦和分析物富集装置

IF 0.5 4区 化学 Q4 CHEMISTRY, MULTIDISCIPLINARY Chemija Pub Date : 2020-10-19 DOI:10.6001/chemija.v31i4.4326
Audrius Sadaunykas, Audrius Zolumskis, Audrius Markevičius, E. Naujalis
{"title":"气相色谱系统的柱上低温聚焦和分析物富集装置","authors":"Audrius Sadaunykas, Audrius Zolumskis, Audrius Markevičius, E. Naujalis","doi":"10.6001/chemija.v31i4.4326","DOIUrl":null,"url":null,"abstract":"Metrology Department, State Research Institute Center for Physical Sciences and Technology, 231 Savanorių Avenue, 02300 Vilnius, Lithuania The objective of this work was to design, construct and test the sample focusing and concentration enrichment device for gas chromatography. The device was based on four metal rings, between which a capillary column and two wire heaters were placed. The metal rings were connected to each other and cooled down using liquid nitrogen. The column was connected to the gas chromatography system using a heated transfer line. The research was conducted on how the length of the cooled column influences focusing and enrichment capabilities of the system. It was found that the analytes were focused better by using a longer cooled part of the column. The longer cooled column was also able to retain a greater volume of the analytes, injected consecutively. By using the 95 cm cooled column length, it was possible to retain 20 injections and detect a 20 times bigger peak area. By changing the temperature of the cooling zone, it was also observed that peak symmetry is heavily dependent on it. Lower cooled zone temperatures produced narrower and more symmetrical peaks.","PeriodicalId":9720,"journal":{"name":"Chemija","volume":" ","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"On-column cryofocusing and analyte enrichment device for gas chromatography systems\",\"authors\":\"Audrius Sadaunykas, Audrius Zolumskis, Audrius Markevičius, E. Naujalis\",\"doi\":\"10.6001/chemija.v31i4.4326\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Metrology Department, State Research Institute Center for Physical Sciences and Technology, 231 Savanorių Avenue, 02300 Vilnius, Lithuania The objective of this work was to design, construct and test the sample focusing and concentration enrichment device for gas chromatography. The device was based on four metal rings, between which a capillary column and two wire heaters were placed. The metal rings were connected to each other and cooled down using liquid nitrogen. The column was connected to the gas chromatography system using a heated transfer line. The research was conducted on how the length of the cooled column influences focusing and enrichment capabilities of the system. It was found that the analytes were focused better by using a longer cooled part of the column. The longer cooled column was also able to retain a greater volume of the analytes, injected consecutively. By using the 95 cm cooled column length, it was possible to retain 20 injections and detect a 20 times bigger peak area. By changing the temperature of the cooling zone, it was also observed that peak symmetry is heavily dependent on it. Lower cooled zone temperatures produced narrower and more symmetrical peaks.\",\"PeriodicalId\":9720,\"journal\":{\"name\":\"Chemija\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2020-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemija\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.6001/chemija.v31i4.4326\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemija","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.6001/chemija.v31i4.4326","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 2

摘要

立陶宛,Vilnius, 02300, savanoriu Avenue, 231,国家物理科学与技术研究中心计量系。本工作的目的是设计、构建和测试气相色谱样品聚焦浓缩装置。该装置基于四个金属环,其中放置了一个毛细管柱和两个线加热器。金属环相互连接,并用液氮冷却。柱通过加热传输线连接到气相色谱系统。研究了冷却柱长度对系统聚焦和富集能力的影响。结果发现,通过使用较长的冷却部分,分析物可以更好地聚焦。较长的冷却柱也能够保留更大体积的分析物,连续注入。通过使用95 cm的冷却柱长度,可以保留20个注射剂,并检测到20倍大的峰面积。通过改变冷却区的温度,还观察到峰对称在很大程度上依赖于它。较低的冷却区温度产生更窄和更对称的峰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On-column cryofocusing and analyte enrichment device for gas chromatography systems
Metrology Department, State Research Institute Center for Physical Sciences and Technology, 231 Savanorių Avenue, 02300 Vilnius, Lithuania The objective of this work was to design, construct and test the sample focusing and concentration enrichment device for gas chromatography. The device was based on four metal rings, between which a capillary column and two wire heaters were placed. The metal rings were connected to each other and cooled down using liquid nitrogen. The column was connected to the gas chromatography system using a heated transfer line. The research was conducted on how the length of the cooled column influences focusing and enrichment capabilities of the system. It was found that the analytes were focused better by using a longer cooled part of the column. The longer cooled column was also able to retain a greater volume of the analytes, injected consecutively. By using the 95 cm cooled column length, it was possible to retain 20 injections and detect a 20 times bigger peak area. By changing the temperature of the cooling zone, it was also observed that peak symmetry is heavily dependent on it. Lower cooled zone temperatures produced narrower and more symmetrical peaks.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Chemija
Chemija 化学-化学综合
CiteScore
1.30
自引率
16.70%
发文量
14
审稿时长
>12 weeks
期刊介绍: Chemija publishes original research articles and reviews from all branches of modern chemistry, including physical, inorganic, analytical, organic, polymer chemistry, electrochemistry, and multidisciplinary approaches.
期刊最新文献
Synthesis and investigation of antibacterial activity of 1-(4-substituted phenyl)-5-oxopyrrolidine-3-carbohydrazide derivatives Hydrogen production on CoFe, CoFeMn and CoFeMo coatings deposited on Ni foam via electroless metal plating Synthesis of novel 4-alkyl-6-(5-aryl-1,2,3-thiadiazol-4-yl) benzene-1,3-diols as potential Hsp90 inhibitors Synthesis and dihydrofolate reductase inhibitory activity of 2-amino-6-(arylaminomethyl) thieno[2,3-d]pyrimidin-4(3H)-ones Synthesis of silver nanoparticles with polyols under reflux and microwave irradiation conditions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1