乌克兰武装部队民族时频信号传输控制与管理存在的问题及目的

E. Koretsky, S. Shevkun, M. Golovnya, O. Mesheryak, V. Bojko, A. Gavrilov, M. Svitenko, M. Trotsko
{"title":"乌克兰武装部队民族时频信号传输控制与管理存在的问题及目的","authors":"E. Koretsky, S. Shevkun, M. Golovnya, O. Mesheryak, V. Bojko, A. Gavrilov, M. Svitenko, M. Trotsko","doi":"10.33955/2307-2180(2)2019.57-61","DOIUrl":null,"url":null,"abstract":"Within the limits of the functioning of the military segment of the single time service and reference frequencies, the problems and ways of solving the tasks of controlling and controlling the transmission of reference signals used by the Armed Forces of Ukraine are outlined. The experimental research on the determination of the accuracy characteristics of the time synchronization system (using the PTP protocol IEEE 1588v2) was implemented for its use in telecommunication networks. As a communication channel, an optical fiber network is specially built to create a synchronization system. Experimental studies confirmed the possibility of transmitting reference signals of time and frequency synchronization with the use of modern digital and fiber-optic technologies from the National Standard of Time and Frequency units to the source standard of the Armed Forces of Ukraine units of time and frequency (VEZSU) with an error that is not exceeds 1 цs And also from VESZU to consumers with an error of less than 10 microseconds at a distance of 600 km via fiber-optic communication channel L2. The creation of a corresponding complex of equipment for monitoring and control of the transmission of reference signals used by the Armed Forces of Ukraine remains relevant.","PeriodicalId":52864,"journal":{"name":"Metrologiia ta priladi","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Problems and Ways to take Objectives with the Control and Management by the Transmission of Ethnic Time and Frequency Signals in the Armed Forces of Ukraine\",\"authors\":\"E. Koretsky, S. Shevkun, M. Golovnya, O. Mesheryak, V. Bojko, A. Gavrilov, M. Svitenko, M. Trotsko\",\"doi\":\"10.33955/2307-2180(2)2019.57-61\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Within the limits of the functioning of the military segment of the single time service and reference frequencies, the problems and ways of solving the tasks of controlling and controlling the transmission of reference signals used by the Armed Forces of Ukraine are outlined. The experimental research on the determination of the accuracy characteristics of the time synchronization system (using the PTP protocol IEEE 1588v2) was implemented for its use in telecommunication networks. As a communication channel, an optical fiber network is specially built to create a synchronization system. Experimental studies confirmed the possibility of transmitting reference signals of time and frequency synchronization with the use of modern digital and fiber-optic technologies from the National Standard of Time and Frequency units to the source standard of the Armed Forces of Ukraine units of time and frequency (VEZSU) with an error that is not exceeds 1 цs And also from VESZU to consumers with an error of less than 10 microseconds at a distance of 600 km via fiber-optic communication channel L2. The creation of a corresponding complex of equipment for monitoring and control of the transmission of reference signals used by the Armed Forces of Ukraine remains relevant.\",\"PeriodicalId\":52864,\"journal\":{\"name\":\"Metrologiia ta priladi\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metrologiia ta priladi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33955/2307-2180(2)2019.57-61\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrologiia ta priladi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33955/2307-2180(2)2019.57-61","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在单一时间服务和参考频率的军事部分的运作范围内,概述了解决控制和控制乌克兰武装部队使用的参考信号传输任务的问题和方法。针对时间同步系统(采用PTP协议IEEE 1588v2)在电信网络中的应用,对其精度特性的确定进行了实验研究。作为通信通道,光纤网络是专门用来创建同步系统的。实验研究证实的可能性发射参考信号的时间和频率同步使用现代数字和光纤技术的国家标准时间和频率单位源标准乌克兰的军队单位的时间和频率(VEZSU)的误差不超过1цs也从VESZU消费者的误差小于10微秒的距离600公里通过光纤通信通道L2。为监测和控制乌克兰武装部队使用的参考信号的传输而建立相应的成套设备仍然是有意义的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Problems and Ways to take Objectives with the Control and Management by the Transmission of Ethnic Time and Frequency Signals in the Armed Forces of Ukraine
Within the limits of the functioning of the military segment of the single time service and reference frequencies, the problems and ways of solving the tasks of controlling and controlling the transmission of reference signals used by the Armed Forces of Ukraine are outlined. The experimental research on the determination of the accuracy characteristics of the time synchronization system (using the PTP protocol IEEE 1588v2) was implemented for its use in telecommunication networks. As a communication channel, an optical fiber network is specially built to create a synchronization system. Experimental studies confirmed the possibility of transmitting reference signals of time and frequency synchronization with the use of modern digital and fiber-optic technologies from the National Standard of Time and Frequency units to the source standard of the Armed Forces of Ukraine units of time and frequency (VEZSU) with an error that is not exceeds 1 цs And also from VESZU to consumers with an error of less than 10 microseconds at a distance of 600 km via fiber-optic communication channel L2. The creation of a corresponding complex of equipment for monitoring and control of the transmission of reference signals used by the Armed Forces of Ukraine remains relevant.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
5 weeks
期刊最新文献
State Primary Standard of Gas Volume and Flow Rate Units for the Pressure Range of 1 MPa to 5 MPa (PVTt-15) THE ARTICLE IS ELLIMINATED Evaluation of the Signal Power Spectrum in Directional Receiving Systems Non-Selective Magnetoelectric Thermal Radiation Receiver Based on Cadmium Antimonide Features, Opportunities and Application of Control Cards Accumulated Sum. Part 2. Numerical Method for Assessing the Disorder of a Technological Process
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1