新一代假肢用于经股骨截肢患者跌倒风险评估和跌倒检测的生物力学措施:范围综述

IF 0.4 Q4 ORTHOPEDICS Journal of Prosthetics and Orthotics Pub Date : 2021-09-27 DOI:10.1097/JPO.0000000000000393
V. Monaco, F. Aprigliano, L. Palmerini, Pierpaolo Palumbo, L. Chiari, S. Micera
{"title":"新一代假肢用于经股骨截肢患者跌倒风险评估和跌倒检测的生物力学措施:范围综述","authors":"V. Monaco, F. Aprigliano, L. Palmerini, Pierpaolo Palumbo, L. Chiari, S. Micera","doi":"10.1097/JPO.0000000000000393","DOIUrl":null,"url":null,"abstract":"ABSTRACT Introduction Transfemoral amputations are known to compromise balance control capabilities, thus increasing the probability of falling. Current research in robotic prostheses is exploring novel strategies to assess the risk of fall and, if required, enable assistive strategies to promote balance recovery. Objectives The aim of this study was to identify a set of biomechanical variables associated with fall risk and fall detection in people with transfemoral amputation (pwTFA), which can be potentially assessed through the next generation of sensorized powered prostheses. Study Design The study design was scoping review. Methods Screening of the literature (CINAHL, PubMed, Scopus, and Web of Science) carried out in February 2020 (quality assessment of retained articles through Downs and Black checklist; retrieved information: measurement tests and biomechanical variables). Results From the initial 595 documents, only 25 citations met eligibility criteria. The pwTFA's fall risk assessment and fall detection are usually carried out by using different measurement tests. Conclusions Two classes of biomechanical markers for fall risk assessment have the potential to be incorporated in self-contained transfemoral powered prostheses equipped with sensory network and suitable computational capabilities. The first consists of kinematic/kinetic variables of some prosthesis components (e.g., foot acceleration, force loading the pylon, knee angle) to detect either an abrupt lack of balance or a fall-related occurrence as a consequence of knee buckling, slipping, or tripping. The second involves implementing automatic procedures to allow pwTFA to routinely carry out clinical tests, such as the timed up and go test and/or the Four Square Step Test to monitor the decline of sensory motor capabilities, likely documenting an increased fall risk. Clinical Relevance The next generation of powered prostheses could both monitor decline on neuromuscular capabilities and gather early signs of an acute lack of balance based on a suitable network of sensors on board. This approach is expected to prevent the fall risk in pwTFA.","PeriodicalId":53702,"journal":{"name":"Journal of Prosthetics and Orthotics","volume":"34 1","pages":"e144 - e162"},"PeriodicalIF":0.4000,"publicationDate":"2021-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biomechanical Measures for Fall Risk Assessment and Fall Detection in People with Transfemoral Amputations for the Next-Generation Prostheses: A Scoping Review\",\"authors\":\"V. Monaco, F. Aprigliano, L. Palmerini, Pierpaolo Palumbo, L. Chiari, S. Micera\",\"doi\":\"10.1097/JPO.0000000000000393\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Introduction Transfemoral amputations are known to compromise balance control capabilities, thus increasing the probability of falling. Current research in robotic prostheses is exploring novel strategies to assess the risk of fall and, if required, enable assistive strategies to promote balance recovery. Objectives The aim of this study was to identify a set of biomechanical variables associated with fall risk and fall detection in people with transfemoral amputation (pwTFA), which can be potentially assessed through the next generation of sensorized powered prostheses. Study Design The study design was scoping review. Methods Screening of the literature (CINAHL, PubMed, Scopus, and Web of Science) carried out in February 2020 (quality assessment of retained articles through Downs and Black checklist; retrieved information: measurement tests and biomechanical variables). Results From the initial 595 documents, only 25 citations met eligibility criteria. The pwTFA's fall risk assessment and fall detection are usually carried out by using different measurement tests. Conclusions Two classes of biomechanical markers for fall risk assessment have the potential to be incorporated in self-contained transfemoral powered prostheses equipped with sensory network and suitable computational capabilities. The first consists of kinematic/kinetic variables of some prosthesis components (e.g., foot acceleration, force loading the pylon, knee angle) to detect either an abrupt lack of balance or a fall-related occurrence as a consequence of knee buckling, slipping, or tripping. The second involves implementing automatic procedures to allow pwTFA to routinely carry out clinical tests, such as the timed up and go test and/or the Four Square Step Test to monitor the decline of sensory motor capabilities, likely documenting an increased fall risk. Clinical Relevance The next generation of powered prostheses could both monitor decline on neuromuscular capabilities and gather early signs of an acute lack of balance based on a suitable network of sensors on board. This approach is expected to prevent the fall risk in pwTFA.\",\"PeriodicalId\":53702,\"journal\":{\"name\":\"Journal of Prosthetics and Orthotics\",\"volume\":\"34 1\",\"pages\":\"e144 - e162\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2021-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetics and Orthotics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/JPO.0000000000000393\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetics and Orthotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/JPO.0000000000000393","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

摘要引言众所周知,经股截肢会损害平衡控制能力,从而增加跌倒的概率。目前对机器人假肢的研究正在探索新的策略来评估跌倒的风险,并在需要时启用辅助策略来促进平衡恢复。目的本研究的目的是确定一组与经股截肢(pwTFA)患者跌倒风险和跌倒检测相关的生物力学变量,这些变量可以通过下一代传感动力假肢进行评估。研究设计研究设计为范围审查。方法对2020年2月进行的文献筛选(CINAHL、PubMed、Scopus和Web of Science)(通过Downs和Black检查表对保留文章进行质量评估;检索信息:测量测试和生物力学变量)。结果在最初的595篇文献中,只有25篇引文符合资格标准。pwTFA的跌倒风险评估和跌倒检测通常通过使用不同的测量测试来进行。结论两类用于跌倒风险评估的生物力学标志物有可能被纳入配备有感觉网络和适当计算能力的自给式经股动力假体中。第一个由一些假体组件的运动学/动力学变量组成(例如,脚加速度、支架上的力负载、膝盖角度),以检测由于膝盖屈曲、滑动或绊倒而导致的突然缺乏平衡或跌倒相关事件。第二个涉及实施自动程序,使pwTFA能够定期进行临床测试,如定时即用测试和/或四步测试,以监测感觉运动能力的下降,可能会记录跌倒风险的增加。临床相关性下一代电动假肢既可以监测神经肌肉能力的下降,也可以根据船上合适的传感器网络收集急性缺乏平衡的早期迹象。这种方法有望防止pwTFA中的跌倒风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Biomechanical Measures for Fall Risk Assessment and Fall Detection in People with Transfemoral Amputations for the Next-Generation Prostheses: A Scoping Review
ABSTRACT Introduction Transfemoral amputations are known to compromise balance control capabilities, thus increasing the probability of falling. Current research in robotic prostheses is exploring novel strategies to assess the risk of fall and, if required, enable assistive strategies to promote balance recovery. Objectives The aim of this study was to identify a set of biomechanical variables associated with fall risk and fall detection in people with transfemoral amputation (pwTFA), which can be potentially assessed through the next generation of sensorized powered prostheses. Study Design The study design was scoping review. Methods Screening of the literature (CINAHL, PubMed, Scopus, and Web of Science) carried out in February 2020 (quality assessment of retained articles through Downs and Black checklist; retrieved information: measurement tests and biomechanical variables). Results From the initial 595 documents, only 25 citations met eligibility criteria. The pwTFA's fall risk assessment and fall detection are usually carried out by using different measurement tests. Conclusions Two classes of biomechanical markers for fall risk assessment have the potential to be incorporated in self-contained transfemoral powered prostheses equipped with sensory network and suitable computational capabilities. The first consists of kinematic/kinetic variables of some prosthesis components (e.g., foot acceleration, force loading the pylon, knee angle) to detect either an abrupt lack of balance or a fall-related occurrence as a consequence of knee buckling, slipping, or tripping. The second involves implementing automatic procedures to allow pwTFA to routinely carry out clinical tests, such as the timed up and go test and/or the Four Square Step Test to monitor the decline of sensory motor capabilities, likely documenting an increased fall risk. Clinical Relevance The next generation of powered prostheses could both monitor decline on neuromuscular capabilities and gather early signs of an acute lack of balance based on a suitable network of sensors on board. This approach is expected to prevent the fall risk in pwTFA.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Prosthetics and Orthotics
Journal of Prosthetics and Orthotics Medicine-Rehabilitation
CiteScore
1.30
自引率
16.70%
发文量
59
期刊介绍: Published quarterly by the AAOP, JPO: Journal of Prosthetics and Orthotics provides information on new devices, fitting and fabrication techniques, and patient management experiences. The focus is on prosthetics and orthotics, with timely reports from related fields such as orthopaedic research, occupational therapy, physical therapy, orthopaedic surgery, amputation surgery, physical medicine, biomedical engineering, psychology, ethics, and gait analysis. Each issue contains research-based articles reviewed and approved by a highly qualified editorial board and an Academy self-study quiz offering two PCE''s.
期刊最新文献
Comparison of Physical Therapy and Orthosis on Clinical Outcomes in Patients with Medial Knee Osteoarthritis Blood Pressure Regulation in Persons with a Transfemoral Amputation: Effects of Wearing a Prosthesis Motion Analysis of a Frontal Plane Adaptable Prosthetic Foot Immediate Effect of Soft Lumbosacral Orthosis on Trunk Stability and Upper-Limb Functionality in Children with Cerebral Palsy Importance of Health Policy and Systems Research for Strengthening Rehabilitation in Health Systems: A Call to Action to Accelerate Progress.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1