Dewi Rizani Ruwahida Ruwahida, I. Rachman, H. A. Widodo, R. Adhitya, Yuda Irawan
{"title":"微控制器和一个基于PLC的通信系统,主机连接和C-Command RS232协议","authors":"Dewi Rizani Ruwahida Ruwahida, I. Rachman, H. A. Widodo, R. Adhitya, Yuda Irawan","doi":"10.35970/infotekmesin.v14i2.1924","DOIUrl":null,"url":null,"abstract":"The communication between microcontrollers and PLC has become an important technology development that needs to be enhanced. One of the reasons for the communication between these two devices is to facilitate the input process of data or information from sensors, which are responsible for detecting or measuring specific parameters. Not all sensors can be directly read by PLC, as some sensors have their own communication protocols or specific libraries that are not directly supported by PLC. Microcontrollers are often used as intermediaries between sensors and PLC. Microcontrollers can read sensor data and then convert it into a format that can be understood by PLC. Microcontrollers can perform flat processing tasks such as conversion and status evaluation to provide more relevant data, and then send this data to the PLC through a compatible communication protocol. In this study, the communication protocol used is the Host Link serial communication using the C-mode Command method. The communication testing conducted using 10 different data samples resulted in accurate values with an error percentage of 0%.","PeriodicalId":33598,"journal":{"name":"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sistem Komunikasi Mikrokontroler dan PLC Berbasis Komunikasi Serial Host Link dan Protokol C-Command RS232\",\"authors\":\"Dewi Rizani Ruwahida Ruwahida, I. Rachman, H. A. Widodo, R. Adhitya, Yuda Irawan\",\"doi\":\"10.35970/infotekmesin.v14i2.1924\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The communication between microcontrollers and PLC has become an important technology development that needs to be enhanced. One of the reasons for the communication between these two devices is to facilitate the input process of data or information from sensors, which are responsible for detecting or measuring specific parameters. Not all sensors can be directly read by PLC, as some sensors have their own communication protocols or specific libraries that are not directly supported by PLC. Microcontrollers are often used as intermediaries between sensors and PLC. Microcontrollers can read sensor data and then convert it into a format that can be understood by PLC. Microcontrollers can perform flat processing tasks such as conversion and status evaluation to provide more relevant data, and then send this data to the PLC through a compatible communication protocol. In this study, the communication protocol used is the Host Link serial communication using the C-mode Command method. The communication testing conducted using 10 different data samples resulted in accurate values with an error percentage of 0%.\",\"PeriodicalId\":33598,\"journal\":{\"name\":\"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35970/infotekmesin.v14i2.1924\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35970/infotekmesin.v14i2.1924","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Sistem Komunikasi Mikrokontroler dan PLC Berbasis Komunikasi Serial Host Link dan Protokol C-Command RS232
The communication between microcontrollers and PLC has become an important technology development that needs to be enhanced. One of the reasons for the communication between these two devices is to facilitate the input process of data or information from sensors, which are responsible for detecting or measuring specific parameters. Not all sensors can be directly read by PLC, as some sensors have their own communication protocols or specific libraries that are not directly supported by PLC. Microcontrollers are often used as intermediaries between sensors and PLC. Microcontrollers can read sensor data and then convert it into a format that can be understood by PLC. Microcontrollers can perform flat processing tasks such as conversion and status evaluation to provide more relevant data, and then send this data to the PLC through a compatible communication protocol. In this study, the communication protocol used is the Host Link serial communication using the C-mode Command method. The communication testing conducted using 10 different data samples resulted in accurate values with an error percentage of 0%.