前置式混合式下吸式蒸发冷却器送风口高度对办公楼室内空气质量的影响

I. Haruna, I. Rufai, Dalhatu Balarabe Yayaya
{"title":"前置式混合式下吸式蒸发冷却器送风口高度对办公楼室内空气质量的影响","authors":"I. Haruna, I. Rufai, Dalhatu Balarabe Yayaya","doi":"10.56958/jesi.2022.7.4.427","DOIUrl":null,"url":null,"abstract":"The hybrid downdraft evaporative cooler (HDEC) conditions a building by cooling with humidification and hence, inappropriate location of its supply outlet on a building facade has a great impact on the indoor air quality (IAQ) which affect the health, concentration, and productivity of the occupants. This paper investigates the effect of the height of the HDEC supply outlet on the IAQ of an office building equipped with the HDEC system in Bayero University Kano. The building model was created using DesignBuilder software while DesignBuilder CFD was employed for the parametric simulation using air change effectiveness (ACE) as the performance criterion. The height of the HDEC supply outlet was varyfrom 0.1m to 2.4m step 0.1m above the floor level. The results show that higher values of ACE in the occupants’ breathing zone were obtained at lower heights of the HDEC supply outlets with the best ACE of 1.1588 obtained at 0.3m. This information could help engineers to optimally position the HDEC supply outlet on the façade of an office building or any other building with similar characteristics.","PeriodicalId":52936,"journal":{"name":"Journal of Engineering Sciences and Innovation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of the height of supply outlet of façade-mounted hybrid downdraft evaporative cooler on the indoor air quality of an office building\",\"authors\":\"I. Haruna, I. Rufai, Dalhatu Balarabe Yayaya\",\"doi\":\"10.56958/jesi.2022.7.4.427\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The hybrid downdraft evaporative cooler (HDEC) conditions a building by cooling with humidification and hence, inappropriate location of its supply outlet on a building facade has a great impact on the indoor air quality (IAQ) which affect the health, concentration, and productivity of the occupants. This paper investigates the effect of the height of the HDEC supply outlet on the IAQ of an office building equipped with the HDEC system in Bayero University Kano. The building model was created using DesignBuilder software while DesignBuilder CFD was employed for the parametric simulation using air change effectiveness (ACE) as the performance criterion. The height of the HDEC supply outlet was varyfrom 0.1m to 2.4m step 0.1m above the floor level. The results show that higher values of ACE in the occupants’ breathing zone were obtained at lower heights of the HDEC supply outlets with the best ACE of 1.1588 obtained at 0.3m. This information could help engineers to optimally position the HDEC supply outlet on the façade of an office building or any other building with similar characteristics.\",\"PeriodicalId\":52936,\"journal\":{\"name\":\"Journal of Engineering Sciences and Innovation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Engineering Sciences and Innovation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.56958/jesi.2022.7.4.427\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering Sciences and Innovation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56958/jesi.2022.7.4.427","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

混合式下吸式蒸发冷却器(HDEC)通过加湿冷却来调节建筑物,因此,其供应出口在建筑物立面上的不适当位置对室内空气质量(IAQ)有很大影响,从而影响居住者的健康、注意力和生产力。本文以卡诺巴耶罗大学为研究对象,研究了HDEC送风口高度对办公楼室内空气质量的影响。采用DesignBuilder软件建立建筑模型,采用DesignBuilder CFD进行参数化模拟,并以空气变化效率(ACE)作为性能标准。HDEC供电出口高度为0.1m - 2.4m,距地面高度0.1m。结果表明:HDEC供电口高度越低,人员呼吸区ACE值越高,在0.3m处ACE值最高,为1.1588;这些信息可以帮助工程师在办公楼或任何其他具有类似特征的建筑物的正面最佳地定位HDEC电源出口。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of the height of supply outlet of façade-mounted hybrid downdraft evaporative cooler on the indoor air quality of an office building
The hybrid downdraft evaporative cooler (HDEC) conditions a building by cooling with humidification and hence, inappropriate location of its supply outlet on a building facade has a great impact on the indoor air quality (IAQ) which affect the health, concentration, and productivity of the occupants. This paper investigates the effect of the height of the HDEC supply outlet on the IAQ of an office building equipped with the HDEC system in Bayero University Kano. The building model was created using DesignBuilder software while DesignBuilder CFD was employed for the parametric simulation using air change effectiveness (ACE) as the performance criterion. The height of the HDEC supply outlet was varyfrom 0.1m to 2.4m step 0.1m above the floor level. The results show that higher values of ACE in the occupants’ breathing zone were obtained at lower heights of the HDEC supply outlets with the best ACE of 1.1588 obtained at 0.3m. This information could help engineers to optimally position the HDEC supply outlet on the façade of an office building or any other building with similar characteristics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊最新文献
Avaliação acústica de um cânion urbano Best operation strategies for piezoelectric vibration energy harvesters. II. Application to simple or induction-assisted resistive loads Some sulphur - containing double combination reagents Passing the systems among levels of quantum reality Stress state in perforated discs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1