英国私人住宅阳台火灾负荷调查

IF 2.3 3区 工程技术 Q2 ENGINEERING, MULTIDISCIPLINARY Fire Technology Pub Date : 2023-08-10 DOI:10.1007/s10694-023-01467-8
Sam Bryant, Ieuan Rickard, Michael Spearpoint
{"title":"英国私人住宅阳台火灾负荷调查","authors":"Sam Bryant,&nbsp;Ieuan Rickard,&nbsp;Michael Spearpoint","doi":"10.1007/s10694-023-01467-8","DOIUrl":null,"url":null,"abstract":"<div><p>Fire loads are often used in the fire safety design of buildings as part of the assessment of the severity of potential fires. Despite recognition that balconies may contain combustible items which could contribute to fire development, there has been little research on balcony fire loads. This paper presents the results of a survey of 1020 balconies on private dwellings across England and the calculated fire loads. Consideration is also given to the influence of key parameters on the fire load energy density. It is found that balconies in England have an average fire load energy density of 64.4 MJ/m<sup>2</sup>, with an 80th percentile value of 110 MJ/m<sup>2</sup>. The influence of selected key parameters on balcony fire loads is also assessed. The results presented provide balcony fire loads which could be considered as part of building design.</p></div>","PeriodicalId":558,"journal":{"name":"Fire Technology","volume":"59 6","pages":"3415 - 3443"},"PeriodicalIF":2.3000,"publicationDate":"2023-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Survey of Fire Loads on Private Residential Balconies in England\",\"authors\":\"Sam Bryant,&nbsp;Ieuan Rickard,&nbsp;Michael Spearpoint\",\"doi\":\"10.1007/s10694-023-01467-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Fire loads are often used in the fire safety design of buildings as part of the assessment of the severity of potential fires. Despite recognition that balconies may contain combustible items which could contribute to fire development, there has been little research on balcony fire loads. This paper presents the results of a survey of 1020 balconies on private dwellings across England and the calculated fire loads. Consideration is also given to the influence of key parameters on the fire load energy density. It is found that balconies in England have an average fire load energy density of 64.4 MJ/m<sup>2</sup>, with an 80th percentile value of 110 MJ/m<sup>2</sup>. The influence of selected key parameters on balcony fire loads is also assessed. The results presented provide balcony fire loads which could be considered as part of building design.</p></div>\",\"PeriodicalId\":558,\"journal\":{\"name\":\"Fire Technology\",\"volume\":\"59 6\",\"pages\":\"3415 - 3443\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10694-023-01467-8\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Technology","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10694-023-01467-8","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

火灾荷载通常用于建筑物的消防安全设计,作为潜在火灾严重性评估的一部分。尽管人们认识到阳台可能含有可能导致火灾发展的可燃物,但对阳台火灾荷载的研究却很少。本文介绍了对英格兰1020个私人住宅阳台的调查结果和计算的火灾荷载。还考虑了关键参数对火灾荷载能量密度的影响。研究发现,英国阳台的平均火灾荷载能量密度为64.4MJ/m2,第80百分位值为110MJ/m2。还评估了选定的关键参数对阳台火灾荷载的影响。研究结果提供了阳台火灾荷载,可作为建筑设计的一部分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Survey of Fire Loads on Private Residential Balconies in England

Fire loads are often used in the fire safety design of buildings as part of the assessment of the severity of potential fires. Despite recognition that balconies may contain combustible items which could contribute to fire development, there has been little research on balcony fire loads. This paper presents the results of a survey of 1020 balconies on private dwellings across England and the calculated fire loads. Consideration is also given to the influence of key parameters on the fire load energy density. It is found that balconies in England have an average fire load energy density of 64.4 MJ/m2, with an 80th percentile value of 110 MJ/m2. The influence of selected key parameters on balcony fire loads is also assessed. The results presented provide balcony fire loads which could be considered as part of building design.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Fire Technology
Fire Technology 工程技术-材料科学:综合
CiteScore
6.60
自引率
14.70%
发文量
137
审稿时长
7.5 months
期刊介绍: Fire Technology publishes original contributions, both theoretical and empirical, that contribute to the solution of problems in fire safety science and engineering. It is the leading journal in the field, publishing applied research dealing with the full range of actual and potential fire hazards facing humans and the environment. It covers the entire domain of fire safety science and engineering problems relevant in industrial, operational, cultural, and environmental applications, including modeling, testing, detection, suppression, human behavior, wildfires, structures, and risk analysis. The aim of Fire Technology is to push forward the frontiers of knowledge and technology by encouraging interdisciplinary communication of significant technical developments in fire protection and subjects of scientific interest to the fire protection community at large. It is published in conjunction with the National Fire Protection Association (NFPA) and the Society of Fire Protection Engineers (SFPE). The mission of NFPA is to help save lives and reduce loss with information, knowledge, and passion. The mission of SFPE is advancing the science and practice of fire protection engineering internationally.
期刊最新文献
Thermal Degradation of Mechanical Properties in Super Ductile Reinforcing Steel Bars: A Comparative Study with Conventional Bars Flame Retarded Adhesive Tapes and Their Influence on the Fire Behavior of Bonded Parts Experimental and Numerical Study on Early-Warning Approach for Fire-Induced Collapse of Steel Portal Frame Based on Rotational Angles Water Spray Effects on Fire Smoke Stratification in a Symmetrical V-Shaped Tunnel Fire Video Intelligent Monitoring Method Based on Moving Target Enhancement and PRV-YOLO Network
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1