基于临床判断的心脏手术患者输血血制品审计

IF 0.2 Q4 ANESTHESIOLOGY Indian Anaesthetists Forum Pub Date : 2022-01-01 DOI:10.4103/theiaforum.theiaforum_41_21
Joseph Paarel, V. Rao, Anand Ganesh, Sukesh Nair, S. Dharmalingam, B. Kurien, R. Sahajanandan
{"title":"基于临床判断的心脏手术患者输血血制品审计","authors":"Joseph Paarel, V. Rao, Anand Ganesh, Sukesh Nair, S. Dharmalingam, B. Kurien, R. Sahajanandan","doi":"10.4103/theiaforum.theiaforum_41_21","DOIUrl":null,"url":null,"abstract":"Background: Transfusion of blood and blood products is strongly associated with increased morbidity and mortality in cardiovascular surgery. This includes transfusion-related acute lung injury, transfusion-associated circulatory overload, renal injury, anaphylactic reactions to blood products, and sepsis. Transfusion of blood products based on the clinician's judgment often results in excessive transfusion. Research suggests that the use of point-of-care (POC) coagulation tests coupled to algorithm-based management decrease transfusion requirements in cardiac surgery. Objectives: To determine abnormal thromboelastograph (TEG) values among patients who received blood products based on clinical judgment and to determine if a POC coagulation test could have resulted in reduced transfusion rates in these patients. Methods: A total of 45 cardiac surgical patients who received blood products during a 3 months period were included in the audit. Coagulation profile and TEG were sent before transfusion for all patients. Data were entered using EPIDATA software. Descriptive analysis was used to define the data. The Fisher exact test was used to assess differences between groups for categorical variables. Results: The R time was abnormal in 4.4% of patients, the Alpha angle was abnormal in 51.1% of patients, maximum amplitude was abnormal in 2.2% of patients, and there was no evidence of fibrinolysis on TEG in these patients. Conclusion: Clinical judgment about the need for blood transfusion had poor correlation with dynamic tests of coagulation. A POC test-based algorithm would have avoided a significant amount of blood product transfusion both in terms of choice of therapy and the dose of component used.","PeriodicalId":42359,"journal":{"name":"Indian Anaesthetists Forum","volume":"23 1","pages":"62 - 67"},"PeriodicalIF":0.2000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An audit on transfusion of blood products based on clinical judgment in patients undergoing cardiac surgery\",\"authors\":\"Joseph Paarel, V. Rao, Anand Ganesh, Sukesh Nair, S. Dharmalingam, B. Kurien, R. Sahajanandan\",\"doi\":\"10.4103/theiaforum.theiaforum_41_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Transfusion of blood and blood products is strongly associated with increased morbidity and mortality in cardiovascular surgery. This includes transfusion-related acute lung injury, transfusion-associated circulatory overload, renal injury, anaphylactic reactions to blood products, and sepsis. Transfusion of blood products based on the clinician's judgment often results in excessive transfusion. Research suggests that the use of point-of-care (POC) coagulation tests coupled to algorithm-based management decrease transfusion requirements in cardiac surgery. Objectives: To determine abnormal thromboelastograph (TEG) values among patients who received blood products based on clinical judgment and to determine if a POC coagulation test could have resulted in reduced transfusion rates in these patients. Methods: A total of 45 cardiac surgical patients who received blood products during a 3 months period were included in the audit. Coagulation profile and TEG were sent before transfusion for all patients. Data were entered using EPIDATA software. Descriptive analysis was used to define the data. The Fisher exact test was used to assess differences between groups for categorical variables. Results: The R time was abnormal in 4.4% of patients, the Alpha angle was abnormal in 51.1% of patients, maximum amplitude was abnormal in 2.2% of patients, and there was no evidence of fibrinolysis on TEG in these patients. Conclusion: Clinical judgment about the need for blood transfusion had poor correlation with dynamic tests of coagulation. A POC test-based algorithm would have avoided a significant amount of blood product transfusion both in terms of choice of therapy and the dose of component used.\",\"PeriodicalId\":42359,\"journal\":{\"name\":\"Indian Anaesthetists Forum\",\"volume\":\"23 1\",\"pages\":\"62 - 67\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Anaesthetists Forum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/theiaforum.theiaforum_41_21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Anaesthetists Forum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/theiaforum.theiaforum_41_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:输血和血液制品与心血管手术中发病率和死亡率的增加密切相关。这包括输血相关的急性肺损伤、输血相关的循环超负荷、肾损伤、对血液制品的过敏反应和败血症。基于临床医生判断的血液制品输血通常会导致过度输血。研究表明,使用护理点(POC)凝血测试结合基于算法的管理可以降低心脏手术中的输血需求。目的:根据临床判断,确定接受血液制品治疗的患者的异常血栓弹性图(TEG)值,并确定POC凝血测试是否会降低这些患者的输血率。方法:共有45名心脏外科患者在3个月内接受了血液制品治疗。所有患者在输血前发送凝血谱和TEG。使用EPIDATA软件输入数据。使用描述性分析来定义数据。Fisher精确检验用于评估分类变量组间的差异。结果:4.4%的患者出现R时间异常,51.1%的患者出现α角异常,2.2%的患者出现最大振幅异常,这些患者的TEG上没有纤维蛋白溶解的迹象。结论:临床判断是否需要输血与凝血动态检测的相关性较差。基于POC测试的算法在治疗选择和所用成分剂量方面都可以避免大量的血液制品输注。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An audit on transfusion of blood products based on clinical judgment in patients undergoing cardiac surgery
Background: Transfusion of blood and blood products is strongly associated with increased morbidity and mortality in cardiovascular surgery. This includes transfusion-related acute lung injury, transfusion-associated circulatory overload, renal injury, anaphylactic reactions to blood products, and sepsis. Transfusion of blood products based on the clinician's judgment often results in excessive transfusion. Research suggests that the use of point-of-care (POC) coagulation tests coupled to algorithm-based management decrease transfusion requirements in cardiac surgery. Objectives: To determine abnormal thromboelastograph (TEG) values among patients who received blood products based on clinical judgment and to determine if a POC coagulation test could have resulted in reduced transfusion rates in these patients. Methods: A total of 45 cardiac surgical patients who received blood products during a 3 months period were included in the audit. Coagulation profile and TEG were sent before transfusion for all patients. Data were entered using EPIDATA software. Descriptive analysis was used to define the data. The Fisher exact test was used to assess differences between groups for categorical variables. Results: The R time was abnormal in 4.4% of patients, the Alpha angle was abnormal in 51.1% of patients, maximum amplitude was abnormal in 2.2% of patients, and there was no evidence of fibrinolysis on TEG in these patients. Conclusion: Clinical judgment about the need for blood transfusion had poor correlation with dynamic tests of coagulation. A POC test-based algorithm would have avoided a significant amount of blood product transfusion both in terms of choice of therapy and the dose of component used.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Anaesthetists Forum
Indian Anaesthetists Forum ANESTHESIOLOGY-
自引率
0.00%
发文量
17
审稿时长
6 weeks
期刊最新文献
Cardiovascular complications in coronavirus disease-2019 patients Refractory hypokalemia in intensive care unit: Efforts in vain Evaluation of effect of dexamethasone and bicarbonate as adjuvants to intracuff lignocaine on endotracheal tube tolerance during emergence and incidence of postoperative cough and sore throat Is it popliteal artery? Is it popliteal vein? No it is persistent sciatic vein Mortality predictors during the third wave of COVID-19 pandemic: A multicentric retrospective analysis from tertiary care centers of Western India
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1