可生物降解聚合物微晶西罗莫司洗脱支架(MiStent)与另一种可生物降解的聚合物西罗莫司Eluting支架(TIVOLI)的随机对照试验:DESSOLVE-C试验

Bin Wang, Sicong Ma, Zhiyong Wang, Li Zhang, H. Pei, Yang Zheng, Yue-jing Yang, Zheng Zhang, Xinqun Hu, Ziwen Ren, Feng Zhang, Changqian Wang, Renqiang Yang, Zhiming Yang, Yuexi Wang, G. Fu, Yu Cao, Zuyi Yuan, K. Xu, Xin Zhao, Bo Xu, M. Qiu, Quanmin Jing
{"title":"可生物降解聚合物微晶西罗莫司洗脱支架(MiStent)与另一种可生物降解的聚合物西罗莫司Eluting支架(TIVOLI)的随机对照试验:DESSOLVE-C试验","authors":"Bin Wang, Sicong Ma, Zhiyong Wang, Li Zhang, H. Pei, Yang Zheng, Yue-jing Yang, Zheng Zhang, Xinqun Hu, Ziwen Ren, Feng Zhang, Changqian Wang, Renqiang Yang, Zhiming Yang, Yuexi Wang, G. Fu, Yu Cao, Zuyi Yuan, K. Xu, Xin Zhao, Bo Xu, M. Qiu, Quanmin Jing","doi":"10.1097/CD9.0000000000000067","DOIUrl":null,"url":null,"abstract":"Objective: Data comparing the outcomes of MiStent (Micell Technologies, Durham, North Carolina, USA) microcrystalline biodegradable polymer (BP) drug-eluting stent (DES) and those of another post-marketing BP-DES, TIVOLI (EssenTech, Beijing, China) are rare. This study sought to compare the angiographic efficacy and clinical outcomes of the microcrystalline BP sirolimus-eluting stent (SES) system MiStent and those of TIVOLI BP-SES. Methods: The DESSOLVE-C trial was a prospective, single-blinded, multicenter, randomized trial (NCT02448524), which randomly assigned patients with de novo coronary lesions to receive MiStent or TIVOLI BP-SES by a 1:1 ratio. The primary endpoint was a non-inferiority comparison of in-stent late lumen loss (LLL) by quantitative coronary angiography at 9 months. The secondary endpoint was device-related clinical cardiovascular composite events (target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (MI), and clinically driven target lesion revascularization) and 1-year outcomes. Results: A total of 428 patients (216 patients in the MiStent group and 212 patients in the TIVOLI group) were enrolled and included in an intention-to-treat analysis. MiStent was not only non-inferior but superior to TIVOLI for in-stent LLL at 9 months ((0.23 ± 0.37) mm vs. (0.34 ± 0.48) mm, P for non-inferiority <0.001, P for superiority = 0.02). Although without significant difference, the rate of TLF in MiStent was quantitatively lower than that in TIVOLI (3.70% vs. 6.60%; P = 0.17). Conclusion: Compared with TIVOLI BP-SES, the MiStent system was superior in in-stent LLL at 9 months and had a comparable clinical benefit at 1 year in de novo coronary lesions.","PeriodicalId":72524,"journal":{"name":"Cardiology discovery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Randomized Controlled Trial of a Biodegradable Polymer, Microcrystalline Sirolimus-Eluting Stent (MiStent) versus Another Biodegradable Polymer Sirolimus-Eluting Stent (TIVOLI): The DESSOLVE-C Trial\",\"authors\":\"Bin Wang, Sicong Ma, Zhiyong Wang, Li Zhang, H. Pei, Yang Zheng, Yue-jing Yang, Zheng Zhang, Xinqun Hu, Ziwen Ren, Feng Zhang, Changqian Wang, Renqiang Yang, Zhiming Yang, Yuexi Wang, G. Fu, Yu Cao, Zuyi Yuan, K. Xu, Xin Zhao, Bo Xu, M. Qiu, Quanmin Jing\",\"doi\":\"10.1097/CD9.0000000000000067\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: Data comparing the outcomes of MiStent (Micell Technologies, Durham, North Carolina, USA) microcrystalline biodegradable polymer (BP) drug-eluting stent (DES) and those of another post-marketing BP-DES, TIVOLI (EssenTech, Beijing, China) are rare. This study sought to compare the angiographic efficacy and clinical outcomes of the microcrystalline BP sirolimus-eluting stent (SES) system MiStent and those of TIVOLI BP-SES. Methods: The DESSOLVE-C trial was a prospective, single-blinded, multicenter, randomized trial (NCT02448524), which randomly assigned patients with de novo coronary lesions to receive MiStent or TIVOLI BP-SES by a 1:1 ratio. The primary endpoint was a non-inferiority comparison of in-stent late lumen loss (LLL) by quantitative coronary angiography at 9 months. The secondary endpoint was device-related clinical cardiovascular composite events (target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (MI), and clinically driven target lesion revascularization) and 1-year outcomes. Results: A total of 428 patients (216 patients in the MiStent group and 212 patients in the TIVOLI group) were enrolled and included in an intention-to-treat analysis. MiStent was not only non-inferior but superior to TIVOLI for in-stent LLL at 9 months ((0.23 ± 0.37) mm vs. (0.34 ± 0.48) mm, P for non-inferiority <0.001, P for superiority = 0.02). Although without significant difference, the rate of TLF in MiStent was quantitatively lower than that in TIVOLI (3.70% vs. 6.60%; P = 0.17). Conclusion: Compared with TIVOLI BP-SES, the MiStent system was superior in in-stent LLL at 9 months and had a comparable clinical benefit at 1 year in de novo coronary lesions.\",\"PeriodicalId\":72524,\"journal\":{\"name\":\"Cardiology discovery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiology discovery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/CD9.0000000000000067\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology discovery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/CD9.0000000000000067","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较MiStent(Micell Technologies,Durham,North Carolina,USA)微晶生物可降解聚合物(BP)药物洗脱支架(DES)和另一种上市后的BP-DES,TIVOLI(EssenTech,Beijing,China)的结果的数据很少。本研究旨在比较微晶BP西罗莫司洗脱支架(SES)系统MiStent和TIVOLI BP-SES的血管造影疗效和临床结果。方法:DESSOLVE-C试验是一项前瞻性、单盲、多中心、随机试验(NCT02448524),以1:1的比例随机分配新发冠状动脉病变患者接受MiStent或TIVOLI BP-SES。主要终点是在9个月时通过定量冠状动脉造影对支架内晚期管腔损失(LLL)进行非劣效性比较。次要终点是器械相关的临床心血管复合事件(靶病变衰竭(TLF)、心脏死亡复合事件、靶血管心肌梗死(MI)和临床驱动的靶病变血运重建)和1年结果。结果:共有428名患者(MiStent组216名患者和TIVOLI组212名患者)被纳入意向治疗分析。MiStent不仅在支架内LLL方面不劣,而且在9个月时优于TIVOLI((0.23 ± 0.37)mm与(0.34 ± 0.48)mm,非劣效性P<0.001,优效性P=0.02)。虽然没有显著差异,但MiStent的TLF发生率在数量上低于TIVOLI(3.70%对6.60%;P=0.17)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Randomized Controlled Trial of a Biodegradable Polymer, Microcrystalline Sirolimus-Eluting Stent (MiStent) versus Another Biodegradable Polymer Sirolimus-Eluting Stent (TIVOLI): The DESSOLVE-C Trial
Objective: Data comparing the outcomes of MiStent (Micell Technologies, Durham, North Carolina, USA) microcrystalline biodegradable polymer (BP) drug-eluting stent (DES) and those of another post-marketing BP-DES, TIVOLI (EssenTech, Beijing, China) are rare. This study sought to compare the angiographic efficacy and clinical outcomes of the microcrystalline BP sirolimus-eluting stent (SES) system MiStent and those of TIVOLI BP-SES. Methods: The DESSOLVE-C trial was a prospective, single-blinded, multicenter, randomized trial (NCT02448524), which randomly assigned patients with de novo coronary lesions to receive MiStent or TIVOLI BP-SES by a 1:1 ratio. The primary endpoint was a non-inferiority comparison of in-stent late lumen loss (LLL) by quantitative coronary angiography at 9 months. The secondary endpoint was device-related clinical cardiovascular composite events (target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (MI), and clinically driven target lesion revascularization) and 1-year outcomes. Results: A total of 428 patients (216 patients in the MiStent group and 212 patients in the TIVOLI group) were enrolled and included in an intention-to-treat analysis. MiStent was not only non-inferior but superior to TIVOLI for in-stent LLL at 9 months ((0.23 ± 0.37) mm vs. (0.34 ± 0.48) mm, P for non-inferiority <0.001, P for superiority = 0.02). Although without significant difference, the rate of TLF in MiStent was quantitatively lower than that in TIVOLI (3.70% vs. 6.60%; P = 0.17). Conclusion: Compared with TIVOLI BP-SES, the MiStent system was superior in in-stent LLL at 9 months and had a comparable clinical benefit at 1 year in de novo coronary lesions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Novel Long QT Syndrome Type 2-associated F129I Mutation in the KCNH2 Gene Significantly Affects I Kr Through the hERG1 Homomeric and Heteromeric Potassium Channels Fulminant Myocarditis Complicated by Stiff-person Syndrome: A Case Report Predictive Value of Carotid-femoral Pulse Wave Velocity for Major Adverse Cardiovascular Events and All-cause Mortality in Different Age Groups of a Chinese Community Home Blood Pressure Monitoring and Its Association With Blood Pressure Control Among Hypertensive Patients With High Cardiovascular Risk in China. Interpretation of the Annual Report on Cardiovascular Health and Diseases in China 2022
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1