法医三维文件的尸体:简单和快速的程序相结合的CT扫描与外部摄影测量数据

Chiara Villa, Mitchell J. Flies, Christina Jacobsen
{"title":"法医三维文件的尸体:简单和快速的程序相结合的CT扫描与外部摄影测量数据","authors":"Chiara Villa,&nbsp;Mitchell J. Flies,&nbsp;Christina Jacobsen","doi":"10.1016/j.jofri.2017.11.003","DOIUrl":null,"url":null,"abstract":"<div><p>This study presents a procedure for combining 3D models obtained from CT scanning (internal and external data) and photogrammetry (external data). 3D data were acquired at different times, without the support of reference points. The procedure has been tested on 30 injured areas caused by different wounding mechanisms. The alignment of the different 3D models was in most of the cases very precisely (mean distance around 1<!--> <!-->mm, SD around or lower than 2<!--> <!-->mm). Ad hoc procedures should be followed in case of injuries on the head, joints and back.</p></div>","PeriodicalId":45371,"journal":{"name":"Journal of Forensic Radiology and Imaging","volume":"12 ","pages":"Pages e2-e7"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jofri.2017.11.003","citationCount":"24","resultStr":"{\"title\":\"Forensic 3D documentation of bodies: Simple and fast procedure for combining CT scanning with external photogrammetry data\",\"authors\":\"Chiara Villa,&nbsp;Mitchell J. Flies,&nbsp;Christina Jacobsen\",\"doi\":\"10.1016/j.jofri.2017.11.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This study presents a procedure for combining 3D models obtained from CT scanning (internal and external data) and photogrammetry (external data). 3D data were acquired at different times, without the support of reference points. The procedure has been tested on 30 injured areas caused by different wounding mechanisms. The alignment of the different 3D models was in most of the cases very precisely (mean distance around 1<!--> <!-->mm, SD around or lower than 2<!--> <!-->mm). Ad hoc procedures should be followed in case of injuries on the head, joints and back.</p></div>\",\"PeriodicalId\":45371,\"journal\":{\"name\":\"Journal of Forensic Radiology and Imaging\",\"volume\":\"12 \",\"pages\":\"Pages e2-e7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.jofri.2017.11.003\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Forensic Radiology and Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2212478017300916\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Forensic Radiology and Imaging","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212478017300916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

摘要

本研究提出了一种结合CT扫描(内部和外部数据)和摄影测量(外部数据)获得的三维模型的方法。在没有参考点支持的情况下,在不同时间获取三维数据。该程序已在30个不同伤害机制造成的受伤区域进行了测试。在大多数情况下,不同3D模型的对齐非常精确(平均距离约为1mm,标准差约为或低于2mm)。在头部、关节和背部受伤的情况下,应遵循特别程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Forensic 3D documentation of bodies: Simple and fast procedure for combining CT scanning with external photogrammetry data

This study presents a procedure for combining 3D models obtained from CT scanning (internal and external data) and photogrammetry (external data). 3D data were acquired at different times, without the support of reference points. The procedure has been tested on 30 injured areas caused by different wounding mechanisms. The alignment of the different 3D models was in most of the cases very precisely (mean distance around 1 mm, SD around or lower than 2 mm). Ad hoc procedures should be followed in case of injuries on the head, joints and back.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Forensic Radiology and Imaging
Journal of Forensic Radiology and Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.70
自引率
0.00%
发文量
0
期刊最新文献
Accuracy of computed radiography in osteometry: A comparison of digital imaging techniques and the effect of magnification Explanation for the contradiction between the results of Diallo et al. (doi:10.1016/j.jofri.2018.10.001) and Winklhofer et al. (doi:10.1097/RLI.0000000000000032) in differentiating ferromagnetic from nonferromagnetic bullets by means of the dual-energy index Juvenile versus adult: A new approach for age estimation from 3-dimensional analyses of the mandibular third molar apices Stature estimation in Iranian population from x-ray measurements of femur and tibia bones Sex identification from foramen magnum using computed tomography scanning in a sample of Egyptian population
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1