{"title":"图像分辨率和压缩对根尖骨分形分析的影响","authors":"S. Toghyani, I. Nasseh, G. Aoun, M. Noujeim","doi":"10.5455/aim.2019.27.167-170","DOIUrl":null,"url":null,"abstract":"Introduction: Fractal dimension (FD) on periapical radiographs is used as a simple descriptor of the complex architecture of the trabecular bone surrounding the dentition. It is used on periapical and panoramic radiographs as a descriptor of the complex architecture of trabecular bone surrounding teeth. Aim: The aim of this study was to evaluate the effect of image resolution and different compression levels on fractal dimension of alveolar bone with images obtained using storage phosphor plate (SPP) system. Methods: Periapical images of premolar and molar teeth on both sides of three dry human mandibles were obtained with Digora Optime (Soredex Corp., Helsinki, Finland) SPP system. The SPPs were exposed equally and scanned immediately after exposure with standard, high and very high resolutions. All the images then were compressed and saved by degrees of 0%, 25%, 50%, 75% and 90%. FD was calculated using public domain software (ImageJ with FracLac plug-in) on two non-overlapping regions of interest (ROIs) on premolar and molar periapical bone areas of each radiograph using differential box-counting method. The ROIs on corresponding images were of the same size and position. FDs were compared using two-way ANOVA and Tukey–Kramer multiple comparison tests (p=0.05). Results: There was no significant difference in FD calculations in different levels of compression for all the resolutions. Images obtained with high resolution scans showed significantly lower variation in FD values compared to very high and standard resolutions for all compressions (p<0.0001). Conclusion: The high resolution demonstrated the lowest variation in FD values in all levels of compression which makes it the most reliable and consistent resolution for measuring the FD values. The level of compression does not make a significant difference in FD values for all the scan resolutions. Scanning resolution of SPPs should be carefully chosen when evaluating the change in FD of alveolar bone for various bone disorders.","PeriodicalId":7074,"journal":{"name":"Acta Informatica Medica","volume":"27 1","pages":"167 - 170"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Effect of Image Resolution and Compression on Fractal Analysis of the Periapical Bone\",\"authors\":\"S. Toghyani, I. Nasseh, G. Aoun, M. Noujeim\",\"doi\":\"10.5455/aim.2019.27.167-170\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Fractal dimension (FD) on periapical radiographs is used as a simple descriptor of the complex architecture of the trabecular bone surrounding the dentition. It is used on periapical and panoramic radiographs as a descriptor of the complex architecture of trabecular bone surrounding teeth. Aim: The aim of this study was to evaluate the effect of image resolution and different compression levels on fractal dimension of alveolar bone with images obtained using storage phosphor plate (SPP) system. Methods: Periapical images of premolar and molar teeth on both sides of three dry human mandibles were obtained with Digora Optime (Soredex Corp., Helsinki, Finland) SPP system. The SPPs were exposed equally and scanned immediately after exposure with standard, high and very high resolutions. All the images then were compressed and saved by degrees of 0%, 25%, 50%, 75% and 90%. FD was calculated using public domain software (ImageJ with FracLac plug-in) on two non-overlapping regions of interest (ROIs) on premolar and molar periapical bone areas of each radiograph using differential box-counting method. The ROIs on corresponding images were of the same size and position. FDs were compared using two-way ANOVA and Tukey–Kramer multiple comparison tests (p=0.05). Results: There was no significant difference in FD calculations in different levels of compression for all the resolutions. Images obtained with high resolution scans showed significantly lower variation in FD values compared to very high and standard resolutions for all compressions (p<0.0001). Conclusion: The high resolution demonstrated the lowest variation in FD values in all levels of compression which makes it the most reliable and consistent resolution for measuring the FD values. The level of compression does not make a significant difference in FD values for all the scan resolutions. Scanning resolution of SPPs should be carefully chosen when evaluating the change in FD of alveolar bone for various bone disorders.\",\"PeriodicalId\":7074,\"journal\":{\"name\":\"Acta Informatica Medica\",\"volume\":\"27 1\",\"pages\":\"167 - 170\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Informatica Medica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5455/aim.2019.27.167-170\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Informatica Medica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/aim.2019.27.167-170","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 10

摘要

根尖周x线片上的分形维数(FD)是牙列周围小梁骨复杂结构的简单描述符。它用于根尖周和全景x线片,作为描述牙齿周围小梁骨复杂结构的描述符。目的:利用存储磷光板(SPP)系统获得的图像,评价图像分辨率和不同压缩水平对牙槽骨分形维数的影响。方法:采用Digora Optime (Soredex Corp., Helsinki, Finland) SPP系统对3例干性下颌骨的前磨牙和双侧磨牙进行根尖周成像。spp均匀暴露,暴露后立即进行标准、高、超高分辨率扫描。然后将所有图像按0%、25%、50%、75%和90%的程度进行压缩和保存。使用公共领域软件(ImageJ with FracLac插件)对每张x线片上前磨牙和磨牙根尖周骨区域的两个非重叠感兴趣区域(roi)采用微分盒计数法计算FD。对应图像上的roi大小和位置相同。fd的比较采用双因素方差分析和Tukey-Kramer多重比较检验(p=0.05)。结果:在不同压缩水平下,所有分辨率的FD计算结果无显著差异。与所有压缩的非常高分辨率和标准分辨率相比,高分辨率扫描获得的图像显示FD值的变化显著降低(p<0.0001)。结论:高分辨率在所有压缩水平下FD值的变化最小,是测量FD值最可靠和一致的分辨率。压缩级别对所有扫描分辨率的FD值没有显著影响。在评价各种骨疾病的牙槽骨FD变化时,应慎重选择spp的扫描分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Image Resolution and Compression on Fractal Analysis of the Periapical Bone
Introduction: Fractal dimension (FD) on periapical radiographs is used as a simple descriptor of the complex architecture of the trabecular bone surrounding the dentition. It is used on periapical and panoramic radiographs as a descriptor of the complex architecture of trabecular bone surrounding teeth. Aim: The aim of this study was to evaluate the effect of image resolution and different compression levels on fractal dimension of alveolar bone with images obtained using storage phosphor plate (SPP) system. Methods: Periapical images of premolar and molar teeth on both sides of three dry human mandibles were obtained with Digora Optime (Soredex Corp., Helsinki, Finland) SPP system. The SPPs were exposed equally and scanned immediately after exposure with standard, high and very high resolutions. All the images then were compressed and saved by degrees of 0%, 25%, 50%, 75% and 90%. FD was calculated using public domain software (ImageJ with FracLac plug-in) on two non-overlapping regions of interest (ROIs) on premolar and molar periapical bone areas of each radiograph using differential box-counting method. The ROIs on corresponding images were of the same size and position. FDs were compared using two-way ANOVA and Tukey–Kramer multiple comparison tests (p=0.05). Results: There was no significant difference in FD calculations in different levels of compression for all the resolutions. Images obtained with high resolution scans showed significantly lower variation in FD values compared to very high and standard resolutions for all compressions (p<0.0001). Conclusion: The high resolution demonstrated the lowest variation in FD values in all levels of compression which makes it the most reliable and consistent resolution for measuring the FD values. The level of compression does not make a significant difference in FD values for all the scan resolutions. Scanning resolution of SPPs should be carefully chosen when evaluating the change in FD of alveolar bone for various bone disorders.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Informatica Medica
Acta Informatica Medica Medicine-Medicine (all)
CiteScore
2.90
自引率
0.00%
发文量
37
期刊最新文献
Correlation Between Carotid Stenosis and Pulsatile Index Measured by Transcranial Doppler. Evaluation of Human Carbonic Anhydrase II (CA-II) Concentration Using ELISA: Insights into Optical Density's Role in Biomarker Quantification for Cryptorchidism Research. Fifteen Years Anniversary of MIE 2009 Conference Held in Sarajevo in the Period August 30th-September 2nd 2009 - Review. Left Portal Hypertension and Hypersplenism in a Child With Congenital Diaphragmatic Hernia: A Rare Case Report. Novel Intronic Heterozygous Mutation in TSC2 Gene in Pediatric Patient with Tuberous Sclerosis Complex.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1