二氧化碳激光超音速拉伸纳米纤维片材萃取水中多环芳烃

I. Ueta, Naho Sekiguchi, A. Suzuki, Yuta Kobayashi, T. Kuwabara, Yoshihiro Saito
{"title":"二氧化碳激光超音速拉伸纳米纤维片材萃取水中多环芳烃","authors":"I. Ueta, Naho Sekiguchi, A. Suzuki, Yuta Kobayashi, T. Kuwabara, Yoshihiro Saito","doi":"10.15583/jpchrom.2020.002","DOIUrl":null,"url":null,"abstract":"An extraction capillary packed with a polyethylene terephthalate nanofiber-sheet was applied for the extraction of five water soluble polycyclic aromatic hydrocarbons (PAHs, including naphthalene (Nap), fluorene (Flu), phenanthrene (Phe), fluoranthene (Flt), and pyrene (Pyr)), in water samples. The extracted PAHs were eluted with acetonitrile, and on-line injected into a high-performance liquid chromatographic system coupled with a fluorescence detector. The limit of detections of the method for Nap, Flu, Phe, Flt, and Pyr were 1.0, 1.0, 0.2, 0.5, and 0.2 ng/mL, respectively, at a sample loading volume of 1.0 mL. The spiked recoveries of the analyte PAHs were in the range of 97.3 to 102% upon spiking the PAHs into tap water and river water samples.","PeriodicalId":91226,"journal":{"name":"Chromatography (Basel)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Carbon Dioxide Laser Supersonic Drawing Nanofiber Sheet for Extraction of Polycyclic Aromatic Hydrocarbons in Water Samples\",\"authors\":\"I. Ueta, Naho Sekiguchi, A. Suzuki, Yuta Kobayashi, T. Kuwabara, Yoshihiro Saito\",\"doi\":\"10.15583/jpchrom.2020.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An extraction capillary packed with a polyethylene terephthalate nanofiber-sheet was applied for the extraction of five water soluble polycyclic aromatic hydrocarbons (PAHs, including naphthalene (Nap), fluorene (Flu), phenanthrene (Phe), fluoranthene (Flt), and pyrene (Pyr)), in water samples. The extracted PAHs were eluted with acetonitrile, and on-line injected into a high-performance liquid chromatographic system coupled with a fluorescence detector. The limit of detections of the method for Nap, Flu, Phe, Flt, and Pyr were 1.0, 1.0, 0.2, 0.5, and 0.2 ng/mL, respectively, at a sample loading volume of 1.0 mL. The spiked recoveries of the analyte PAHs were in the range of 97.3 to 102% upon spiking the PAHs into tap water and river water samples.\",\"PeriodicalId\":91226,\"journal\":{\"name\":\"Chromatography (Basel)\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-02-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chromatography (Basel)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15583/jpchrom.2020.002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chromatography (Basel)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15583/jpchrom.2020.002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

采用填充聚对苯二甲酸乙二醇酯纳米纤维片的萃取毛细管萃取水样中的五种水溶性多环芳烃(PAHs,包括萘(Nap)、芴(Flu)、菲(Phe)、荧蒽(Flt)和芘(Pyr))。提取的多环芳烃用乙腈洗脱,并在线注入与荧光检测器耦合的高效液相色谱系统。在1.0 mL的样品加载体积下,该方法对Nap、Flu、Phe、Flt和Pyr的检测限分别为1.0、1.0、0.2、0.5和0.2 ng/mL。在自来水和河水样品中加入PAHs后,分析物PAHs的加标回收率在97.3至102%范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Carbon Dioxide Laser Supersonic Drawing Nanofiber Sheet for Extraction of Polycyclic Aromatic Hydrocarbons in Water Samples
An extraction capillary packed with a polyethylene terephthalate nanofiber-sheet was applied for the extraction of five water soluble polycyclic aromatic hydrocarbons (PAHs, including naphthalene (Nap), fluorene (Flu), phenanthrene (Phe), fluoranthene (Flt), and pyrene (Pyr)), in water samples. The extracted PAHs were eluted with acetonitrile, and on-line injected into a high-performance liquid chromatographic system coupled with a fluorescence detector. The limit of detections of the method for Nap, Flu, Phe, Flt, and Pyr were 1.0, 1.0, 0.2, 0.5, and 0.2 ng/mL, respectively, at a sample loading volume of 1.0 mL. The spiked recoveries of the analyte PAHs were in the range of 97.3 to 102% upon spiking the PAHs into tap water and river water samples.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Determination of L-Carnitine and Acetyl-L-carnitine in Aspergillus oryzae- Fermented Rice Bran Product by Hydrophobic Derivatization–LC/ESI-MS/MS Development of Systematic Separation Method of the Ingredients Containing in Crude Aloin Using Countercurrent Chromatography Current Bioanalysis of Molecularly Targeted Drugs Using Liquid Chromatography–Tandem Mass Spectrometry Residual Analysis of Aflatoxin M1 in Cheese by HPLC Coupled with Solid Phase Dispersive Extraction and Solid-Phase Fluorescence Derivatization Method, and Its Accuracy Management for Method Validation Effects of Enteral Formulas and Their Food Protein and Dietary Fiber Components on Postprandial Plasma Warfarin Concentration in Rats
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1