经食管超声心动图在儿童偏心闭塞小肋间切口高室间隔缺损闭合中的应用

Jin Yu, Jingjing Ye, Zewei Zhang, Jian-hua Li, Jingjing Qian, Xiuzhen Yang, Liang-long Ma
{"title":"经食管超声心动图在儿童偏心闭塞小肋间切口高室间隔缺损闭合中的应用","authors":"Jin Yu, Jingjing Ye, Zewei Zhang, Jian-hua Li, Jingjing Qian, Xiuzhen Yang, Liang-long Ma","doi":"10.3760/CMA.J.ISSN.1004-4477.2019.10.004","DOIUrl":null,"url":null,"abstract":"Objective \nTo explore the value of transesophageal echocardiography (TEE) in high ventricular septal defect (VSD) occlusion via a left parasternal ultra-minimal intercostal incision (≤1 cm) with eccentric occluder in children. \n \n \nMethods \nForty-eight children with high VSD underwent device occlusion via ultraminimal intercostal incision with eccentric occluder. The whole operation, including preoperative evaluation, intraoperative localization and guidance and postoperation evaluation were performed under the guidance of TEE. \n \n \nResults \nForty-six children with high VSD underwent successfully device closure in all 48 cases and the operation success rate was 95.8%. The average size of high VSD was 2.2-6.0 (3.70±0.90)mm and the average size of eccentric occluder was 4-8 (5.48±1.12)mm. The average operation duration was 18-98 (49.80±16.71)min. There were 2 cases of peri-membranous high VSD and 44 cases of outlet-typle VSD, of which 10 cases of mild aortic valve prolapses (AVOP), including 5 cases of aortic valve regurgitation(AR). In addition, there was 1 case of replacement of device, 1 case of having septum below the margin of the defect and 1 case of using a dilator for a small defect. The 46 cases were followed up for 6 to 42 months, and the pericardial effusion occured in 3 cases and disappeared during follow-up. No other abnormal conditions were found. \n \n \nConclusions \nDuring the surgery of high VSD device occlusion via ultraminimal intercostal incision with eccentric occluder, TEE has an important value in defect assessment, intraoperative localization and guidance, and immediate evaluation of efficacy, and can effectively guide the device occlusion of high VSD. \n \n \nKey words: \nEchocardiography, transesophageal; Ventricular septal defect; Minimal surgical procedures; Children","PeriodicalId":10224,"journal":{"name":"中华超声影像学杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Application of transesophageal echocardiography in high ventricular septal defect closure via the small intercostal incision with eccentric occluder in children\",\"authors\":\"Jin Yu, Jingjing Ye, Zewei Zhang, Jian-hua Li, Jingjing Qian, Xiuzhen Yang, Liang-long Ma\",\"doi\":\"10.3760/CMA.J.ISSN.1004-4477.2019.10.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective \\nTo explore the value of transesophageal echocardiography (TEE) in high ventricular septal defect (VSD) occlusion via a left parasternal ultra-minimal intercostal incision (≤1 cm) with eccentric occluder in children. \\n \\n \\nMethods \\nForty-eight children with high VSD underwent device occlusion via ultraminimal intercostal incision with eccentric occluder. The whole operation, including preoperative evaluation, intraoperative localization and guidance and postoperation evaluation were performed under the guidance of TEE. \\n \\n \\nResults \\nForty-six children with high VSD underwent successfully device closure in all 48 cases and the operation success rate was 95.8%. The average size of high VSD was 2.2-6.0 (3.70±0.90)mm and the average size of eccentric occluder was 4-8 (5.48±1.12)mm. The average operation duration was 18-98 (49.80±16.71)min. There were 2 cases of peri-membranous high VSD and 44 cases of outlet-typle VSD, of which 10 cases of mild aortic valve prolapses (AVOP), including 5 cases of aortic valve regurgitation(AR). In addition, there was 1 case of replacement of device, 1 case of having septum below the margin of the defect and 1 case of using a dilator for a small defect. The 46 cases were followed up for 6 to 42 months, and the pericardial effusion occured in 3 cases and disappeared during follow-up. No other abnormal conditions were found. \\n \\n \\nConclusions \\nDuring the surgery of high VSD device occlusion via ultraminimal intercostal incision with eccentric occluder, TEE has an important value in defect assessment, intraoperative localization and guidance, and immediate evaluation of efficacy, and can effectively guide the device occlusion of high VSD. \\n \\n \\nKey words: \\nEchocardiography, transesophageal; Ventricular septal defect; Minimal surgical procedures; Children\",\"PeriodicalId\":10224,\"journal\":{\"name\":\"中华超声影像学杂志\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华超声影像学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.1004-4477.2019.10.004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华超声影像学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1004-4477.2019.10.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

摘要

目的探讨经食管超声心动图(TEE)在小儿高室间隔缺损(VSD)经左胸骨旁超小肋间切口(≤1cm)偏心闭塞术中的应用价值。方法对48例高室间隔缺损患儿采用偏心闭塞器经肋间小切口闭塞。整个手术在TEE的指导下进行,包括术前评价、术中定位指导及术后评价。结果48例高VSD患儿46例均成功闭合,手术成功率为95.8%。高VSD平均大小为2.2 ~ 6.0(3.70±0.90)mm,偏心闭塞平均大小为4 ~ 8(5.48±1.12)mm。平均手术时间18 ~ 98(49.80±16.71)min。膜周高VSD 2例,出口型VSD 44例,其中轻度主动脉瓣脱垂(AVOP) 10例,其中主动脉瓣反流(AR) 5例。此外,有1例更换装置,1例在缺损边缘以下有隔膜,1例使用扩张器治疗小缺损。46例患者随访6 ~ 42个月,3例出现心包积液,随访中消失。未发现其他异常情况。结论在偏心闭塞器超小肋间切口高位VSD闭塞术中,TEE在缺损评估、术中定位指导、即刻疗效评价等方面具有重要价值,可有效指导高位VSD闭塞术。关键词:超声心动图;经食管;室间隔缺损;最少的外科手术;孩子们
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Application of transesophageal echocardiography in high ventricular septal defect closure via the small intercostal incision with eccentric occluder in children
Objective To explore the value of transesophageal echocardiography (TEE) in high ventricular septal defect (VSD) occlusion via a left parasternal ultra-minimal intercostal incision (≤1 cm) with eccentric occluder in children. Methods Forty-eight children with high VSD underwent device occlusion via ultraminimal intercostal incision with eccentric occluder. The whole operation, including preoperative evaluation, intraoperative localization and guidance and postoperation evaluation were performed under the guidance of TEE. Results Forty-six children with high VSD underwent successfully device closure in all 48 cases and the operation success rate was 95.8%. The average size of high VSD was 2.2-6.0 (3.70±0.90)mm and the average size of eccentric occluder was 4-8 (5.48±1.12)mm. The average operation duration was 18-98 (49.80±16.71)min. There were 2 cases of peri-membranous high VSD and 44 cases of outlet-typle VSD, of which 10 cases of mild aortic valve prolapses (AVOP), including 5 cases of aortic valve regurgitation(AR). In addition, there was 1 case of replacement of device, 1 case of having septum below the margin of the defect and 1 case of using a dilator for a small defect. The 46 cases were followed up for 6 to 42 months, and the pericardial effusion occured in 3 cases and disappeared during follow-up. No other abnormal conditions were found. Conclusions During the surgery of high VSD device occlusion via ultraminimal intercostal incision with eccentric occluder, TEE has an important value in defect assessment, intraoperative localization and guidance, and immediate evaluation of efficacy, and can effectively guide the device occlusion of high VSD. Key words: Echocardiography, transesophageal; Ventricular septal defect; Minimal surgical procedures; Children
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中华超声影像学杂志
中华超声影像学杂志 Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.80
自引率
0.00%
发文量
9126
期刊介绍:
期刊最新文献
Ultrasound-guided pathological sampling of cadaver lung tissue in cases of COVID-19 Ultrasound-guided post-mortem tissue sampling in the autopsy of COVID-19 cases: a pilot study The clinical value of ultrasound in the assessment of the severity of COVID-19 Study of positioning of fetal conus medullaris by detecting atlanto-axial intervertebral space with three-dimensional ultrasound Prenatal ultrasound diagnostic clues of congenital dislocation of the knee
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1