Fatima Amin, A. S. Shaikh, S. Bangash, A. Kamran, Nida Rafique, M. Rehman, Najma Patel
{"title":"术中直接超声心动图与经食管超声心动图评价法洛四联症患者右心室流出道压力梯度的相关性","authors":"Fatima Amin, A. S. Shaikh, S. Bangash, A. Kamran, Nida Rafique, M. Rehman, Najma Patel","doi":"10.47144/phj.v56i1.2484","DOIUrl":null,"url":null,"abstract":"Objectives: The objective of this study was to determine the correlation between intraoperative direct (needle) and transesophageal echocardiographic (TEE) assessment of right ventricular outflow tract (RVOT) pressure gradient in patients undergoing Tetralogy of Fallot (TOF) repair.\nMethodology: A total of 100 patients underwent for TOF repair were included. After completion of surgery and successful weaning from cardiopulmonary bypass, the TEE derived RVOT gradients were obtained from, the midesophageal ascending aortic short axis (AA Sax) view, upper esophageal aortic arch short axis (Arch Sax) view and trans-gastric RV outflow (TG RV outflow) view. Direct (needle) derived pressures from right ventricular (RV) and pulmonary artery (PA) were obtained by surgeon using a saline filled pressure transducer system. Correlation coefficient was computed between intraoperative direct and TEE assessment of RVOT gradient was evaluated.\nResults: In the sample of 100 patients, 41% were females and median age was 8 [5-11] years. The TEE derived RVOT gradients obtained in AA Sax, Arch Sax and TG RV outflow view were 26.46±6.98, 26.60±6.55, and 22.64±6.21 mmHg, respectively. Intraoperative RVOT pressure gradient was 19.05±8.9 mmHg. The correlation between intraoperative direct (needle) and TEE assessment of RVOT pressure gradient obtained in AA Sax, Arch Sax, and TG RV outflow view were 0.588 (p<0.001), 0.283 (p<0.001), and 0.383 (p<0.001), respectively.\nConclusion: Intraoperative TEE assessment of RVOT pressure gradient showed a moderate correlation with the direct (needle) assessment. The ascending aorta short axis view was found to be the superior esophageal view.","PeriodicalId":42273,"journal":{"name":"Pakistan Heart Journal","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Correlation between Intraoperative Direct and Transesophageal Echocardiographic Assessment of Right Ventricular Outflow Tract Pressure Gradient in Patients Undergoing Tetralogy of Fallot Repair\",\"authors\":\"Fatima Amin, A. S. Shaikh, S. Bangash, A. Kamran, Nida Rafique, M. Rehman, Najma Patel\",\"doi\":\"10.47144/phj.v56i1.2484\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives: The objective of this study was to determine the correlation between intraoperative direct (needle) and transesophageal echocardiographic (TEE) assessment of right ventricular outflow tract (RVOT) pressure gradient in patients undergoing Tetralogy of Fallot (TOF) repair.\\nMethodology: A total of 100 patients underwent for TOF repair were included. After completion of surgery and successful weaning from cardiopulmonary bypass, the TEE derived RVOT gradients were obtained from, the midesophageal ascending aortic short axis (AA Sax) view, upper esophageal aortic arch short axis (Arch Sax) view and trans-gastric RV outflow (TG RV outflow) view. Direct (needle) derived pressures from right ventricular (RV) and pulmonary artery (PA) were obtained by surgeon using a saline filled pressure transducer system. Correlation coefficient was computed between intraoperative direct and TEE assessment of RVOT gradient was evaluated.\\nResults: In the sample of 100 patients, 41% were females and median age was 8 [5-11] years. The TEE derived RVOT gradients obtained in AA Sax, Arch Sax and TG RV outflow view were 26.46±6.98, 26.60±6.55, and 22.64±6.21 mmHg, respectively. Intraoperative RVOT pressure gradient was 19.05±8.9 mmHg. The correlation between intraoperative direct (needle) and TEE assessment of RVOT pressure gradient obtained in AA Sax, Arch Sax, and TG RV outflow view were 0.588 (p<0.001), 0.283 (p<0.001), and 0.383 (p<0.001), respectively.\\nConclusion: Intraoperative TEE assessment of RVOT pressure gradient showed a moderate correlation with the direct (needle) assessment. The ascending aorta short axis view was found to be the superior esophageal view.\",\"PeriodicalId\":42273,\"journal\":{\"name\":\"Pakistan Heart Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pakistan Heart Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47144/phj.v56i1.2484\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pakistan Heart Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47144/phj.v56i1.2484","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Correlation between Intraoperative Direct and Transesophageal Echocardiographic Assessment of Right Ventricular Outflow Tract Pressure Gradient in Patients Undergoing Tetralogy of Fallot Repair
Objectives: The objective of this study was to determine the correlation between intraoperative direct (needle) and transesophageal echocardiographic (TEE) assessment of right ventricular outflow tract (RVOT) pressure gradient in patients undergoing Tetralogy of Fallot (TOF) repair.
Methodology: A total of 100 patients underwent for TOF repair were included. After completion of surgery and successful weaning from cardiopulmonary bypass, the TEE derived RVOT gradients were obtained from, the midesophageal ascending aortic short axis (AA Sax) view, upper esophageal aortic arch short axis (Arch Sax) view and trans-gastric RV outflow (TG RV outflow) view. Direct (needle) derived pressures from right ventricular (RV) and pulmonary artery (PA) were obtained by surgeon using a saline filled pressure transducer system. Correlation coefficient was computed between intraoperative direct and TEE assessment of RVOT gradient was evaluated.
Results: In the sample of 100 patients, 41% were females and median age was 8 [5-11] years. The TEE derived RVOT gradients obtained in AA Sax, Arch Sax and TG RV outflow view were 26.46±6.98, 26.60±6.55, and 22.64±6.21 mmHg, respectively. Intraoperative RVOT pressure gradient was 19.05±8.9 mmHg. The correlation between intraoperative direct (needle) and TEE assessment of RVOT pressure gradient obtained in AA Sax, Arch Sax, and TG RV outflow view were 0.588 (p<0.001), 0.283 (p<0.001), and 0.383 (p<0.001), respectively.
Conclusion: Intraoperative TEE assessment of RVOT pressure gradient showed a moderate correlation with the direct (needle) assessment. The ascending aorta short axis view was found to be the superior esophageal view.