Plínio de Oliveira Holanda, Nely Marjollie Guanabara Teixeira Reis, J. Nascimento, Felipe Paiva Alencar, Marilman Maciel Benício
{"title":"新型冠状病毒肺炎患者延长机械通气期间麻醉装置吸入氧分数调整工具的提出","authors":"Plínio de Oliveira Holanda, Nely Marjollie Guanabara Teixeira Reis, J. Nascimento, Felipe Paiva Alencar, Marilman Maciel Benício","doi":"10.4236/ojanes.2021.1110029","DOIUrl":null,"url":null,"abstract":"The COVID-19 pandemic has had a major impact on health care services, leading to a breakdown in public and private health systems worldwide. A major challenge was the scarcity of mechanical ventilators, which resulted in the use of anaesthesia devices for this purpose. However, they are quite different from mechanical ventilators used in Intensive Care Units and some adaptations, such as the use of high flow to reduce CO2 rebreathing, were necessary to ensure patient safety. The objective of this study was to present a mathematical formula and develop a tool that can be used to adjust the flow of oxygen and air in flow metres of anaesthesia devices that do not have oxygen analysers or these analysers are not operational. A literature review was conducted using the main health databases and libraries as research sources: PubMed, Virtual Health Library (VHL), SciELO, and Cochrane. The review included studies published in English, Spanish, and Portuguese. Animal studies were excluded. A total of 11 references were included to support this article.","PeriodicalId":90667,"journal":{"name":"","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2021-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Proposition of a Tool to Adjust the Inspired Oxygen Fraction in Anesthesia Devices during Prolonged Mechanical Ventilation in COVID-19 Patients\",\"authors\":\"Plínio de Oliveira Holanda, Nely Marjollie Guanabara Teixeira Reis, J. Nascimento, Felipe Paiva Alencar, Marilman Maciel Benício\",\"doi\":\"10.4236/ojanes.2021.1110029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The COVID-19 pandemic has had a major impact on health care services, leading to a breakdown in public and private health systems worldwide. A major challenge was the scarcity of mechanical ventilators, which resulted in the use of anaesthesia devices for this purpose. However, they are quite different from mechanical ventilators used in Intensive Care Units and some adaptations, such as the use of high flow to reduce CO2 rebreathing, were necessary to ensure patient safety. The objective of this study was to present a mathematical formula and develop a tool that can be used to adjust the flow of oxygen and air in flow metres of anaesthesia devices that do not have oxygen analysers or these analysers are not operational. A literature review was conducted using the main health databases and libraries as research sources: PubMed, Virtual Health Library (VHL), SciELO, and Cochrane. The review included studies published in English, Spanish, and Portuguese. Animal studies were excluded. A total of 11 references were included to support this article.\",\"PeriodicalId\":90667,\"journal\":{\"name\":\"\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0,\"publicationDate\":\"2021-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4236/ojanes.2021.1110029\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/ojanes.2021.1110029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Proposition of a Tool to Adjust the Inspired Oxygen Fraction in Anesthesia Devices during Prolonged Mechanical Ventilation in COVID-19 Patients
The COVID-19 pandemic has had a major impact on health care services, leading to a breakdown in public and private health systems worldwide. A major challenge was the scarcity of mechanical ventilators, which resulted in the use of anaesthesia devices for this purpose. However, they are quite different from mechanical ventilators used in Intensive Care Units and some adaptations, such as the use of high flow to reduce CO2 rebreathing, were necessary to ensure patient safety. The objective of this study was to present a mathematical formula and develop a tool that can be used to adjust the flow of oxygen and air in flow metres of anaesthesia devices that do not have oxygen analysers or these analysers are not operational. A literature review was conducted using the main health databases and libraries as research sources: PubMed, Virtual Health Library (VHL), SciELO, and Cochrane. The review included studies published in English, Spanish, and Portuguese. Animal studies were excluded. A total of 11 references were included to support this article.