现代住宅的固有频率测量

B. Setiawan, N. Al-Huda, A. Yulianur, Nora Abdullah, Juellyan Juellyan, Athalya Khanza Permana, Jihan Indria Sawitri
{"title":"现代住宅的固有频率测量","authors":"B. Setiawan, N. Al-Huda, A. Yulianur, Nora Abdullah, Juellyan Juellyan, Athalya Khanza Permana, Jihan Indria Sawitri","doi":"10.13170/aijst.11.3.28765","DOIUrl":null,"url":null,"abstract":"Around 1000 to 4000 units of modest dwelling houses are annually built in Aceh Province. A modest dwelling house is a small type of house with limitations in space planning which is very suitable for small families with middle to lower incomes. This lower middle-class community is a group of people who are very vulnerable and will be very severely affected when a disaster occurs. A modest dwelling house is a one-story building with simple construction and structure in its physical form. On the other hand, Aceh is also one area that is very prone to earthquake disasters from along the subduction zone and Sumatran Fault. Therefore, measuring the frequency of a modest dwelling house is crucial to understanding all house elements' conditions. It is essential to estimate the integrity and safety of the house after an earthquake occurs. The method used in this research is using the field experiment method in the form of measuring the natural response of the building to vibration based on microtremor data. This study uses a seismometer. The data is stored in a data logger. The seismometer is placed on the floor of the house. Data collection is carried out when no major activities are around the house. Measurements were carried out for a minimum of 60 minutes. Computer analysis with specific parameters obtained using Geopsy software. The result of this study indicates that the dominant frequency of modest dwelling houses measured is around 2.99 Hz. The analysis results from the field experiment were validated using pushover analysis of the detailed engineering design data. The modeling results show that in the x-axis direction (parallel to the direction of the building), the frequency obtained is 7.14 Hz. Pushover analysis on the model with the y-axis direction (parallel to the side of the building) obtained a frequency of 7.46 Hz. This validation shows a huge difference between the frequency of field measurement results and computer modeling results. Many factors, including decreasing or degrading the concrete construction quality in the field, can cause this gap.","PeriodicalId":7128,"journal":{"name":"Aceh International Journal of Science and Technology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Natural Frequency Measurement of Modest Dwelling Houses\",\"authors\":\"B. Setiawan, N. Al-Huda, A. Yulianur, Nora Abdullah, Juellyan Juellyan, Athalya Khanza Permana, Jihan Indria Sawitri\",\"doi\":\"10.13170/aijst.11.3.28765\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Around 1000 to 4000 units of modest dwelling houses are annually built in Aceh Province. A modest dwelling house is a small type of house with limitations in space planning which is very suitable for small families with middle to lower incomes. This lower middle-class community is a group of people who are very vulnerable and will be very severely affected when a disaster occurs. A modest dwelling house is a one-story building with simple construction and structure in its physical form. On the other hand, Aceh is also one area that is very prone to earthquake disasters from along the subduction zone and Sumatran Fault. Therefore, measuring the frequency of a modest dwelling house is crucial to understanding all house elements' conditions. It is essential to estimate the integrity and safety of the house after an earthquake occurs. The method used in this research is using the field experiment method in the form of measuring the natural response of the building to vibration based on microtremor data. This study uses a seismometer. The data is stored in a data logger. The seismometer is placed on the floor of the house. Data collection is carried out when no major activities are around the house. Measurements were carried out for a minimum of 60 minutes. Computer analysis with specific parameters obtained using Geopsy software. The result of this study indicates that the dominant frequency of modest dwelling houses measured is around 2.99 Hz. The analysis results from the field experiment were validated using pushover analysis of the detailed engineering design data. The modeling results show that in the x-axis direction (parallel to the direction of the building), the frequency obtained is 7.14 Hz. Pushover analysis on the model with the y-axis direction (parallel to the side of the building) obtained a frequency of 7.46 Hz. This validation shows a huge difference between the frequency of field measurement results and computer modeling results. Many factors, including decreasing or degrading the concrete construction quality in the field, can cause this gap.\",\"PeriodicalId\":7128,\"journal\":{\"name\":\"Aceh International Journal of Science and Technology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aceh International Journal of Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.13170/aijst.11.3.28765\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aceh International Journal of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13170/aijst.11.3.28765","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

亚齐省每年建造大约1000至4000套普通住宅。适度住宅是一种空间规划有限的小型住宅,非常适合中低收入的小家庭。这个中下层社区是一群非常脆弱的人,当灾难发生时,他们将受到非常严重的影响。普通住宅是一种单层建筑,在物理形式上具有简单的构造和结构。另一方面,亚齐也是沿俯冲带和苏门答腊断层的地震灾害易发地区之一。因此,测量普通住宅的频率对于了解所有住宅元素的条件至关重要。地震发生后,评估房屋的完整性和安全性是至关重要的。本研究采用的方法是以微震数据为基础,测量建筑物对振动的自然反应的现场实验方法。这项研究使用了地震仪。数据存储在数据记录器中。地震仪放在房子的地板上。数据收集是在房屋周围没有主要活动时进行的。测量时间至少为60分钟。计算机分析,具体参数用地质软件得到。研究结果表明,中等住宅的主导频率在2.99 Hz左右。通过对详细工程设计数据的推覆分析,验证了现场试验的分析结果。模拟结果表明,在x轴方向(平行于建筑方向),得到的频率为7.14 Hz。对模型进行y轴方向(平行于建筑物侧面)的推覆分析,得到频率为7.46 Hz。这一验证表明,现场测量结果与计算机模拟结果的频率存在巨大差异。造成这种差距的因素很多,包括现场混凝土施工质量的下降或退化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Natural Frequency Measurement of Modest Dwelling Houses
Around 1000 to 4000 units of modest dwelling houses are annually built in Aceh Province. A modest dwelling house is a small type of house with limitations in space planning which is very suitable for small families with middle to lower incomes. This lower middle-class community is a group of people who are very vulnerable and will be very severely affected when a disaster occurs. A modest dwelling house is a one-story building with simple construction and structure in its physical form. On the other hand, Aceh is also one area that is very prone to earthquake disasters from along the subduction zone and Sumatran Fault. Therefore, measuring the frequency of a modest dwelling house is crucial to understanding all house elements' conditions. It is essential to estimate the integrity and safety of the house after an earthquake occurs. The method used in this research is using the field experiment method in the form of measuring the natural response of the building to vibration based on microtremor data. This study uses a seismometer. The data is stored in a data logger. The seismometer is placed on the floor of the house. Data collection is carried out when no major activities are around the house. Measurements were carried out for a minimum of 60 minutes. Computer analysis with specific parameters obtained using Geopsy software. The result of this study indicates that the dominant frequency of modest dwelling houses measured is around 2.99 Hz. The analysis results from the field experiment were validated using pushover analysis of the detailed engineering design data. The modeling results show that in the x-axis direction (parallel to the direction of the building), the frequency obtained is 7.14 Hz. Pushover analysis on the model with the y-axis direction (parallel to the side of the building) obtained a frequency of 7.46 Hz. This validation shows a huge difference between the frequency of field measurement results and computer modeling results. Many factors, including decreasing or degrading the concrete construction quality in the field, can cause this gap.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
19
审稿时长
8 weeks
期刊最新文献
Structural Health Monitoring by Identification Dynamic Properties and Load Rating Factor at Multi-span Prestressed Concrete Girder Bridge Isotherm and Kinetic Adsorption of Cadmium (Cd) onto Biosorbent Made from Kepok Banana Peel (Musa Acuminata balbisian): the Effect of Activator Type and Biosorbent Dosage Life Cycle Cost Analysis and Payback Period of 12-kW Wind Turbine for a Remote Telecommunications Base Station Simulation of Multi Reservoir Operation Rules with Interconnected Tunnel and Water Transfer Simple Technology of Material Physics of Groundwater Conservation in Dealing with Climate Change in Disaster Areas of North Sumatra
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1