基于改进Whale优化算法的有源配电网故障定位

A. Bahmanyar, H. Borhani-Bahabadi, S. Jamali
{"title":"基于改进Whale优化算法的有源配电网故障定位","authors":"A. Bahmanyar, H. Borhani-Bahabadi, S. Jamali","doi":"10.22068/IJEEE.16.3.302","DOIUrl":null,"url":null,"abstract":"To realize the self-healing concept of smart grids, an accurate and reliable fault locator is a prerequisite. This paper presents a new fault location method for active power distribution networks which is based on measured voltage sag and use of whale optimization algorithm (WOA). The fault induced voltage sag depends on the fault location and resistance. Therefore, the fault location can be found by investigation of voltage sags recorded throughout the distribution network. However, this approach requires a considerable effort to check all possible fault location and resistance values to find the correct solution. In this paper, an improved version of the WOA is proposed to find the fault location as an optimization problem. This optimization technique employs a number of agents (whales) to search for a bunch of fish in the optimal position, i.e. the fault location and its resistance. The method is applicable to different distribution network configurations. The accuracy of the method is verified by simulation tests on a distribution feeder and comparative analysis with two other deterministic methods reported in the literature. The simulation results indicate that the proposed optimized method gives more accurate and reliable results.","PeriodicalId":39055,"journal":{"name":"Iranian Journal of Electrical and Electronic Engineering","volume":"16 1","pages":"302-312"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Fault Location in Active Distribution Networks Using Improved Whale Optimization Algorithm\",\"authors\":\"A. Bahmanyar, H. Borhani-Bahabadi, S. Jamali\",\"doi\":\"10.22068/IJEEE.16.3.302\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To realize the self-healing concept of smart grids, an accurate and reliable fault locator is a prerequisite. This paper presents a new fault location method for active power distribution networks which is based on measured voltage sag and use of whale optimization algorithm (WOA). The fault induced voltage sag depends on the fault location and resistance. Therefore, the fault location can be found by investigation of voltage sags recorded throughout the distribution network. However, this approach requires a considerable effort to check all possible fault location and resistance values to find the correct solution. In this paper, an improved version of the WOA is proposed to find the fault location as an optimization problem. This optimization technique employs a number of agents (whales) to search for a bunch of fish in the optimal position, i.e. the fault location and its resistance. The method is applicable to different distribution network configurations. The accuracy of the method is verified by simulation tests on a distribution feeder and comparative analysis with two other deterministic methods reported in the literature. The simulation results indicate that the proposed optimized method gives more accurate and reliable results.\",\"PeriodicalId\":39055,\"journal\":{\"name\":\"Iranian Journal of Electrical and Electronic Engineering\",\"volume\":\"16 1\",\"pages\":\"302-312\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Journal of Electrical and Electronic Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22068/IJEEE.16.3.302\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Energy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Electrical and Electronic Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22068/IJEEE.16.3.302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
引用次数: 1

摘要

要实现智能电网的自我修复概念,准确可靠的故障定位器是前提。本文提出了一种新的有源配电网故障定位方法,该方法基于实测电压暂降和鲸鱼优化算法(WOA)。故障引起的电压暂降取决于故障位置和电阻。因此,可以通过调查整个配电网中记录的电压骤降来找到故障位置。然而,这种方法需要付出相当大的努力来检查所有可能的故障位置和电阻值,以找到正确的解决方案。本文提出了一种改进的WOA,将故障定位作为一个优化问题。这种优化技术使用许多代理(鲸鱼)来搜索处于最佳位置的一群鱼,即故障位置及其电阻。该方法适用于不同的配电网配置。通过对配电馈线的模拟测试以及与文献中报道的其他两种确定性方法的比较分析,验证了该方法的准确性。仿真结果表明,所提出的优化方法给出了更准确可靠的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fault Location in Active Distribution Networks Using Improved Whale Optimization Algorithm
To realize the self-healing concept of smart grids, an accurate and reliable fault locator is a prerequisite. This paper presents a new fault location method for active power distribution networks which is based on measured voltage sag and use of whale optimization algorithm (WOA). The fault induced voltage sag depends on the fault location and resistance. Therefore, the fault location can be found by investigation of voltage sags recorded throughout the distribution network. However, this approach requires a considerable effort to check all possible fault location and resistance values to find the correct solution. In this paper, an improved version of the WOA is proposed to find the fault location as an optimization problem. This optimization technique employs a number of agents (whales) to search for a bunch of fish in the optimal position, i.e. the fault location and its resistance. The method is applicable to different distribution network configurations. The accuracy of the method is verified by simulation tests on a distribution feeder and comparative analysis with two other deterministic methods reported in the literature. The simulation results indicate that the proposed optimized method gives more accurate and reliable results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Iranian Journal of Electrical and Electronic Engineering
Iranian Journal of Electrical and Electronic Engineering Engineering-Electrical and Electronic Engineering
CiteScore
1.70
自引率
0.00%
发文量
13
审稿时长
12 weeks
期刊最新文献
Robust Operation Planning With Participation of Flexibility Resources Both on Generation and Demand Sides Under Uncertainty of Wind-based Generation Units A Novel Droop-based Control Strategy for Improving the Performance of VSC-MTDC Systems in Post-Contingency Conditions Securing Reliability Constrained Technology Combination for Isolated Micro-Grid Using Multi-Agent Based Optimization View-Invariant and Robust Gait Recognition Using Gait Energy Images of Leg Region and Masking Altered Sections Multiple Electricity Markets Competitiveness Undergoing Symmetric and Asymmetric Renewables Development Policies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1