{"title":"污染条件下帽针式绝缘子电场和电压分布的有限元建模","authors":"Oussama Ghermoul, Hani Benguesmia, L. Benyettou","doi":"10.29354/diag/159517","DOIUrl":null,"url":null,"abstract":"The knowledge of the behavior of both the electric potential and electric field is one of the main factors needed when designing an insulator. Using AutoCAD software a 2D cap and pin 1512L insulator model was created in the clean state and under pollution from one to five insulators separately making a chain of insulators for a total of 10 models. Later they are imported to COMSOL Multiphysics 5.6 software, simulations of the 1512L insulator were made to see the effect the pollution has and the differences that occur on the distribution with the addition of more insulators in the chain. The potential distribution starts to develop a pattern after a certain number of insulators in the chain while the pollution induces high value spikes in the field distribution. Finite-element-analysis for numerical simulation of the pollution effect in outdoor insulators: a review and a novel method.","PeriodicalId":52164,"journal":{"name":"Diagnostyka","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Finite element modeling for electric field and voltage distribution along the cap and pin insulators under pollution\",\"authors\":\"Oussama Ghermoul, Hani Benguesmia, L. Benyettou\",\"doi\":\"10.29354/diag/159517\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The knowledge of the behavior of both the electric potential and electric field is one of the main factors needed when designing an insulator. Using AutoCAD software a 2D cap and pin 1512L insulator model was created in the clean state and under pollution from one to five insulators separately making a chain of insulators for a total of 10 models. Later they are imported to COMSOL Multiphysics 5.6 software, simulations of the 1512L insulator were made to see the effect the pollution has and the differences that occur on the distribution with the addition of more insulators in the chain. The potential distribution starts to develop a pattern after a certain number of insulators in the chain while the pollution induces high value spikes in the field distribution. Finite-element-analysis for numerical simulation of the pollution effect in outdoor insulators: a review and a novel method.\",\"PeriodicalId\":52164,\"journal\":{\"name\":\"Diagnostyka\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostyka\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29354/diag/159517\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostyka","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29354/diag/159517","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
Finite element modeling for electric field and voltage distribution along the cap and pin insulators under pollution
The knowledge of the behavior of both the electric potential and electric field is one of the main factors needed when designing an insulator. Using AutoCAD software a 2D cap and pin 1512L insulator model was created in the clean state and under pollution from one to five insulators separately making a chain of insulators for a total of 10 models. Later they are imported to COMSOL Multiphysics 5.6 software, simulations of the 1512L insulator were made to see the effect the pollution has and the differences that occur on the distribution with the addition of more insulators in the chain. The potential distribution starts to develop a pattern after a certain number of insulators in the chain while the pollution induces high value spikes in the field distribution. Finite-element-analysis for numerical simulation of the pollution effect in outdoor insulators: a review and a novel method.
期刊介绍:
Diagnostyka – is a quarterly published by the Polish Society of Technical Diagnostics (PSTD). The journal “Diagnostyka” was established by the decision of the Presidium of Main Board of the Polish Society of Technical Diagnostics on August, 21st 2000 and replaced published since 1990 reference book of the PSTD named “Diagnosta”. In the years 2000-2003 there were issued annually two numbers of the journal, since 2004 “Diagnostyka” is issued as a quarterly. Research areas covered include: -theory of the technical diagnostics, -experimental diagnostic research of processes, objects and systems, -analytical, symptom and simulation models of technical objects, -algorithms, methods and devices for diagnosing, prognosis and genesis of condition of technical objects, -methods for detection, localization and identification of damages of technical objects, -artificial intelligence in diagnostics, neural nets, fuzzy systems, genetic algorithms, expert systems, -application of technical diagnostics, -diagnostic issues in mechanical and civil engineering, -medical and biological diagnostics with signal processing application, -structural health monitoring, -machines, -noise and vibration, -analysis of technical and civil systems.