基于不同制造技术的文件系统在暴露于NaOCl和多次灭菌循环后的抗循环疲劳性的比较评估

Q3 Dentistry Endodontology Pub Date : 2022-07-01 DOI:10.4103/endo.endo_90_19
Pulkit Malhotra, P. Bansal, V. Nikhil, S. Jaiswal, Sachin Gupta
{"title":"基于不同制造技术的文件系统在暴露于NaOCl和多次灭菌循环后的抗循环疲劳性的比较评估","authors":"Pulkit Malhotra, P. Bansal, V. Nikhil, S. Jaiswal, Sachin Gupta","doi":"10.4103/endo.endo_90_19","DOIUrl":null,"url":null,"abstract":"Aim: To comparatively evaluate in vitro the cyclic fatigue resistance of different file systems based on different manufacturing technologies after exposure to NaOCl and multiple sterilization cycles. Materials and Methods: Sixty new Nickel − Titanium (NiTi) rotary files were selected and divided into five groups (n = 12) based on different manufacturing technology. These groups were: Protaper Universal (GPT) (DentsplyMaillefer, Ballaigues, Switzerland) Protaper Next (GPTN) (Dentsply, Tulsa, OK, USA), Twisted files (GTF) (Sybron Endo, Orange, CA, USA), Neoniti (GNL) (Neolix, France), and Hyflex CM (GHCM) (Coltene/whaledent inc., 235 Ascort Parkway, Cuyahoga falls, OH, USA). Files were sterilized in an autoclave at 121°C at 15 psi for 15 min and exposed to 5.0% NaOCl solution for 30 s before cyclic fatigue testing till instrument fracture using a standardized grooved block assembly with the artificial canal at 90° angle of curvature using a 16:1 reduction hand-piece powered by a torque-controlled motor. This whole procedure of autoclaving, immersion in sodium hypochlorite solution and rotating in a stainless steel assembly was repeated again and again until the file fractured. Results: The highest mean for the number of cycles before fracture was observed with Neoniti (GNL) and lowest for Hyflex CM (GHCM). The difference between GPT vs GTF, GPTvs GNL, GNLvs GHCM; GPTNvs GTF, GPTNvs GNL, GPTNvs GHCM; GTFvs GNL, GTFvs GHCM and GNL VS GHCM was statistically significant, whereas the difference between GPTvs GPTN was statistically nonsignificant. Conclusion: Neoniti and twisted file systems resisted the maximum number of cycles to fracture at 90° angle of curvature after exposure to 5% sodium hypochlorite solution and multiple autoclaving cycles. Hyflex CM showed the least resistance in the similar conditions.","PeriodicalId":11607,"journal":{"name":"Endodontology","volume":"34 1","pages":"151 - 155"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative evaluation of cyclic fatigue resistance of file systems based on different manufacturing technologies after exposure to NaOCl and multiple sterilization cycles\",\"authors\":\"Pulkit Malhotra, P. Bansal, V. Nikhil, S. Jaiswal, Sachin Gupta\",\"doi\":\"10.4103/endo.endo_90_19\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: To comparatively evaluate in vitro the cyclic fatigue resistance of different file systems based on different manufacturing technologies after exposure to NaOCl and multiple sterilization cycles. Materials and Methods: Sixty new Nickel − Titanium (NiTi) rotary files were selected and divided into five groups (n = 12) based on different manufacturing technology. These groups were: Protaper Universal (GPT) (DentsplyMaillefer, Ballaigues, Switzerland) Protaper Next (GPTN) (Dentsply, Tulsa, OK, USA), Twisted files (GTF) (Sybron Endo, Orange, CA, USA), Neoniti (GNL) (Neolix, France), and Hyflex CM (GHCM) (Coltene/whaledent inc., 235 Ascort Parkway, Cuyahoga falls, OH, USA). Files were sterilized in an autoclave at 121°C at 15 psi for 15 min and exposed to 5.0% NaOCl solution for 30 s before cyclic fatigue testing till instrument fracture using a standardized grooved block assembly with the artificial canal at 90° angle of curvature using a 16:1 reduction hand-piece powered by a torque-controlled motor. This whole procedure of autoclaving, immersion in sodium hypochlorite solution and rotating in a stainless steel assembly was repeated again and again until the file fractured. Results: The highest mean for the number of cycles before fracture was observed with Neoniti (GNL) and lowest for Hyflex CM (GHCM). The difference between GPT vs GTF, GPTvs GNL, GNLvs GHCM; GPTNvs GTF, GPTNvs GNL, GPTNvs GHCM; GTFvs GNL, GTFvs GHCM and GNL VS GHCM was statistically significant, whereas the difference between GPTvs GPTN was statistically nonsignificant. Conclusion: Neoniti and twisted file systems resisted the maximum number of cycles to fracture at 90° angle of curvature after exposure to 5% sodium hypochlorite solution and multiple autoclaving cycles. Hyflex CM showed the least resistance in the similar conditions.\",\"PeriodicalId\":11607,\"journal\":{\"name\":\"Endodontology\",\"volume\":\"34 1\",\"pages\":\"151 - 155\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Endodontology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/endo.endo_90_19\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/endo.endo_90_19","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较评价不同制造工艺的不同文件系统在NaOCl暴露和多次灭菌循环后的体外抗循环疲劳性能。材料与方法:选择60个新型镍钛(NiTi)旋转锉,根据不同的制造工艺分为5组(n = 12)。这些组分别是:Protaper Universal (GPT) (DentsplyMaillefer,瑞士Ballaigues) Protaper Next (GPTN) (Dentsply, Tulsa, OK, USA), Twisted files (GTF) (Sybron Endo, Orange, CA, USA), Neoniti (GNL) (Neolix, France)和Hyflex CM (GHCM) (Coltene/whaledent inc., 235 Ascort Parkway, Cuyahoga falls, OH, USA)。锉刀在121°C, 15psi的高压灭菌器中灭菌15分钟,暴露于5.0% NaOCl溶液中30秒,然后进行循环疲劳测试,直到使用标准化槽块组件和人工管在90°曲率角下使用16:1减速手件进行仪器断裂,由扭矩控制电机驱动。高压灭菌、浸泡在次氯酸钠溶液中并在不锈钢组件中旋转的整个过程一遍又一遍地重复,直到锉刀断裂。结果:骨折前平均周期数以Neoniti (GNL)组最高,Hyflex CM (GHCM)组最低。GPT与GTF、GPTvs GNL、GNLvs GHCM的区别GPTNvs GTF, GPTNvs GNL, GPTNvs GHCM;GTFvs GNL、GTFvs GHCM、GNL VS GHCM差异有统计学意义,GPTvs GPTN差异无统计学意义。结论:暴露于5%次氯酸钠溶液和多次高压灭菌循环后,新生儿和扭曲的文件系统在90°曲率角处抵抗了最大循环次数的断裂。在相同条件下,Hyflex CM表现出最小的抗性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative evaluation of cyclic fatigue resistance of file systems based on different manufacturing technologies after exposure to NaOCl and multiple sterilization cycles
Aim: To comparatively evaluate in vitro the cyclic fatigue resistance of different file systems based on different manufacturing technologies after exposure to NaOCl and multiple sterilization cycles. Materials and Methods: Sixty new Nickel − Titanium (NiTi) rotary files were selected and divided into five groups (n = 12) based on different manufacturing technology. These groups were: Protaper Universal (GPT) (DentsplyMaillefer, Ballaigues, Switzerland) Protaper Next (GPTN) (Dentsply, Tulsa, OK, USA), Twisted files (GTF) (Sybron Endo, Orange, CA, USA), Neoniti (GNL) (Neolix, France), and Hyflex CM (GHCM) (Coltene/whaledent inc., 235 Ascort Parkway, Cuyahoga falls, OH, USA). Files were sterilized in an autoclave at 121°C at 15 psi for 15 min and exposed to 5.0% NaOCl solution for 30 s before cyclic fatigue testing till instrument fracture using a standardized grooved block assembly with the artificial canal at 90° angle of curvature using a 16:1 reduction hand-piece powered by a torque-controlled motor. This whole procedure of autoclaving, immersion in sodium hypochlorite solution and rotating in a stainless steel assembly was repeated again and again until the file fractured. Results: The highest mean for the number of cycles before fracture was observed with Neoniti (GNL) and lowest for Hyflex CM (GHCM). The difference between GPT vs GTF, GPTvs GNL, GNLvs GHCM; GPTNvs GTF, GPTNvs GNL, GPTNvs GHCM; GTFvs GNL, GTFvs GHCM and GNL VS GHCM was statistically significant, whereas the difference between GPTvs GPTN was statistically nonsignificant. Conclusion: Neoniti and twisted file systems resisted the maximum number of cycles to fracture at 90° angle of curvature after exposure to 5% sodium hypochlorite solution and multiple autoclaving cycles. Hyflex CM showed the least resistance in the similar conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Endodontology
Endodontology Medicine-Anatomy
CiteScore
0.60
自引率
0.00%
发文量
0
审稿时长
28 weeks
期刊最新文献
Comparative evaluation of the clinical and radiographic success of regenerative endodontic procedures in immature versus mature permanent incisors with apical periodontitis: A prospective observational study Sealing efficacy of various rubber dam barrier materials used for isolation procedures: A randomized controlled trial Evaluation of fracture resistance of radicular dentin treated with nanochitosan-loaded calcium hydroxide and nanographene-loaded calcium hydroxide, when used as intracanal medicament: An in vitro study Fracture resistance of endodontically treated maxillary premolars using indirect and direct composite onlays: A comparative study Effect of bonding pericervical dentin with reinforcing materials on strength of root-filled mandibular single-canal premolars: An in vitro study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1