近端主动脉夹层重建的混合技术

IF 1.1 Q4 MEDICINE, RESEARCH & EXPERIMENTAL Sovremennye Tehnologii v Medicine Pub Date : 2023-01-01 Epub Date: 2023-05-28 DOI:10.17691/stm2023.15.3.05
D A Sirota, M O Zhulkov, D S Khvan, T Caus, B N Kozlov, A V Protopopov, A G Makayev, A V Fomichev, Kh A Agayeva, A K Sabetov, V L Lukinov, A G Edemsky, A M Chernyavsky
{"title":"近端主动脉夹层重建的混合技术","authors":"D A Sirota, M O Zhulkov, D S Khvan, T Caus, B N Kozlov, A V Protopopov, A G Makayev, A V Fomichev, Kh A Agayeva, A K Sabetov, V L Lukinov, A G Edemsky, A M Chernyavsky","doi":"10.17691/stm2023.15.3.05","DOIUrl":null,"url":null,"abstract":"<p><p><b>The aim of the study</b> is to evaluate the efficacy of various types of hybrid technology in compare to the classical repair of the aortic arch of type I aortic dissection treatment in the in-hospital period.</p><p><strong>Materials and methods: </strong>A retrospective observational study has been conducted, the results of surgical treatment of 213 patients with DeBakey type I aortic dissection operated on within the period from 2001 to 2017 were compared. Patients were divided into three groups: in group 1, patients undergone a hemiarch type of aortic repair or the total arch replacement (n=121); in group 2, a hemiarch aortic reconstruction and implantation of bare metal stent was performed (n=55); in group 3, a frozen elephant trunk technique was used (n=37). Taking into consideration the retrospective character of the investigation and nonequivalence of the groups by separate characteristics, they were equalized to improve the reliability of the results using the PSM (propensity score matching) pseudorandomization method. As a result, three groups of comparison were formed which were equalized by the PSM method and called PSM 1, 2, and 3. The mortality and complication rate in the in-hospital period, as well as the frequency of false lumen thrombosis development depending on the treatment method, have been analyzed.</p><p><strong>Results: </strong>The mortality rate in the PSM 1 group was 15 patients: group 1 (standard technique) - 10 patients (9%), group 2 (uncoated stents) - 5 patients (11%). A significant difference was found in the number of major bleedings (group 1 - 8%, group 2 - 21%, p=0.031) and cases of bowel ischemia (group 1 - 1%, group 2 - 9%, p=0.028). Complete false lumen thrombosis of the thoracic aorta was observed significantly more often in group 1 than in group 2 (22% vs 5%, p=0.015).In the examined group PSM 2, hospital mortality rate was 4 patients: group 1 - 3 patients (12%), group 3 - 1 patient (3%). No differences between the groups were found in the number of complications. In group 3, complete false lumen thrombosis of the thoracic aorta was observed in 59% of cases, whereas in group 1 it was found only in 4% of patients (p<0.001).In comparison group PSM 3, the mortality was 8 patients: group 2 - 5 patients (11%), group 3 - 3 patients (9%). The number of neurological complications differed significantly: in group 2 - 27%, in group 3 - 6% (p=0.019). Besides, 3% of cases of complete false lumen thrombosis were found in group 2, while there appeared 55% (p<0.001) of such patients in group 3.</p><p><strong>Conclusion: </strong>The comparative analysis showed that the use of bare metal stents and hybrid prostheses demonstrated a comparable low level of in-hospital mortality compared to the standard surgical technique of aortic arch reconstruction. At the same time, the use of the bare metal stents is associated with a higher rate of perioperative complications (bleeding, postoperative bowel ischemia, neurological complications) compared to the standard treatment and repair of the aortic dissection using hybrid prostheses. Complete thrombosis of the false lumen occurred significantly less commonly in case of using bare metal stents than with standard treatment and hybrid prostheses.</p>","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10904355/pdf/","citationCount":"0","resultStr":"{\"title\":\"Hybrid Technologies for Reconstruction of Proximal Aortic Dissection.\",\"authors\":\"D A Sirota, M O Zhulkov, D S Khvan, T Caus, B N Kozlov, A V Protopopov, A G Makayev, A V Fomichev, Kh A Agayeva, A K Sabetov, V L Lukinov, A G Edemsky, A M Chernyavsky\",\"doi\":\"10.17691/stm2023.15.3.05\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>The aim of the study</b> is to evaluate the efficacy of various types of hybrid technology in compare to the classical repair of the aortic arch of type I aortic dissection treatment in the in-hospital period.</p><p><strong>Materials and methods: </strong>A retrospective observational study has been conducted, the results of surgical treatment of 213 patients with DeBakey type I aortic dissection operated on within the period from 2001 to 2017 were compared. Patients were divided into three groups: in group 1, patients undergone a hemiarch type of aortic repair or the total arch replacement (n=121); in group 2, a hemiarch aortic reconstruction and implantation of bare metal stent was performed (n=55); in group 3, a frozen elephant trunk technique was used (n=37). Taking into consideration the retrospective character of the investigation and nonequivalence of the groups by separate characteristics, they were equalized to improve the reliability of the results using the PSM (propensity score matching) pseudorandomization method. As a result, three groups of comparison were formed which were equalized by the PSM method and called PSM 1, 2, and 3. The mortality and complication rate in the in-hospital period, as well as the frequency of false lumen thrombosis development depending on the treatment method, have been analyzed.</p><p><strong>Results: </strong>The mortality rate in the PSM 1 group was 15 patients: group 1 (standard technique) - 10 patients (9%), group 2 (uncoated stents) - 5 patients (11%). A significant difference was found in the number of major bleedings (group 1 - 8%, group 2 - 21%, p=0.031) and cases of bowel ischemia (group 1 - 1%, group 2 - 9%, p=0.028). Complete false lumen thrombosis of the thoracic aorta was observed significantly more often in group 1 than in group 2 (22% vs 5%, p=0.015).In the examined group PSM 2, hospital mortality rate was 4 patients: group 1 - 3 patients (12%), group 3 - 1 patient (3%). No differences between the groups were found in the number of complications. In group 3, complete false lumen thrombosis of the thoracic aorta was observed in 59% of cases, whereas in group 1 it was found only in 4% of patients (p<0.001).In comparison group PSM 3, the mortality was 8 patients: group 2 - 5 patients (11%), group 3 - 3 patients (9%). The number of neurological complications differed significantly: in group 2 - 27%, in group 3 - 6% (p=0.019). Besides, 3% of cases of complete false lumen thrombosis were found in group 2, while there appeared 55% (p<0.001) of such patients in group 3.</p><p><strong>Conclusion: </strong>The comparative analysis showed that the use of bare metal stents and hybrid prostheses demonstrated a comparable low level of in-hospital mortality compared to the standard surgical technique of aortic arch reconstruction. At the same time, the use of the bare metal stents is associated with a higher rate of perioperative complications (bleeding, postoperative bowel ischemia, neurological complications) compared to the standard treatment and repair of the aortic dissection using hybrid prostheses. Complete thrombosis of the false lumen occurred significantly less commonly in case of using bare metal stents than with standard treatment and hybrid prostheses.</p>\",\"PeriodicalId\":51886,\"journal\":{\"name\":\"Sovremennye Tehnologii v Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10904355/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sovremennye Tehnologii v Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17691/stm2023.15.3.05\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sovremennye Tehnologii v Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17691/stm2023.15.3.05","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/28 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是评价不同类型的混合技术在I型主动脉夹层的住院期间与传统主动脉弓修复治疗的疗效。材料与方法。回顾性观察研究对2001 ~ 2017年213例DeBakey I型主动脉夹层患者的手术治疗结果进行比较。患者被分为三组:第一组,患者接受血弓型主动脉修复或全弓置换术(n=121);第2组,主动脉血出血重建术并置入金属支架(n=55);第三组采用冷冻象鼻技术(n=37)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Hybrid Technologies for Reconstruction of Proximal Aortic Dissection.

The aim of the study is to evaluate the efficacy of various types of hybrid technology in compare to the classical repair of the aortic arch of type I aortic dissection treatment in the in-hospital period.

Materials and methods: A retrospective observational study has been conducted, the results of surgical treatment of 213 patients with DeBakey type I aortic dissection operated on within the period from 2001 to 2017 were compared. Patients were divided into three groups: in group 1, patients undergone a hemiarch type of aortic repair or the total arch replacement (n=121); in group 2, a hemiarch aortic reconstruction and implantation of bare metal stent was performed (n=55); in group 3, a frozen elephant trunk technique was used (n=37). Taking into consideration the retrospective character of the investigation and nonequivalence of the groups by separate characteristics, they were equalized to improve the reliability of the results using the PSM (propensity score matching) pseudorandomization method. As a result, three groups of comparison were formed which were equalized by the PSM method and called PSM 1, 2, and 3. The mortality and complication rate in the in-hospital period, as well as the frequency of false lumen thrombosis development depending on the treatment method, have been analyzed.

Results: The mortality rate in the PSM 1 group was 15 patients: group 1 (standard technique) - 10 patients (9%), group 2 (uncoated stents) - 5 patients (11%). A significant difference was found in the number of major bleedings (group 1 - 8%, group 2 - 21%, p=0.031) and cases of bowel ischemia (group 1 - 1%, group 2 - 9%, p=0.028). Complete false lumen thrombosis of the thoracic aorta was observed significantly more often in group 1 than in group 2 (22% vs 5%, p=0.015).In the examined group PSM 2, hospital mortality rate was 4 patients: group 1 - 3 patients (12%), group 3 - 1 patient (3%). No differences between the groups were found in the number of complications. In group 3, complete false lumen thrombosis of the thoracic aorta was observed in 59% of cases, whereas in group 1 it was found only in 4% of patients (p<0.001).In comparison group PSM 3, the mortality was 8 patients: group 2 - 5 patients (11%), group 3 - 3 patients (9%). The number of neurological complications differed significantly: in group 2 - 27%, in group 3 - 6% (p=0.019). Besides, 3% of cases of complete false lumen thrombosis were found in group 2, while there appeared 55% (p<0.001) of such patients in group 3.

Conclusion: The comparative analysis showed that the use of bare metal stents and hybrid prostheses demonstrated a comparable low level of in-hospital mortality compared to the standard surgical technique of aortic arch reconstruction. At the same time, the use of the bare metal stents is associated with a higher rate of perioperative complications (bleeding, postoperative bowel ischemia, neurological complications) compared to the standard treatment and repair of the aortic dissection using hybrid prostheses. Complete thrombosis of the false lumen occurred significantly less commonly in case of using bare metal stents than with standard treatment and hybrid prostheses.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sovremennye Tehnologii v Medicine
Sovremennye Tehnologii v Medicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.80
自引率
0.00%
发文量
38
期刊最新文献
Sphingomyelins of Local Fat Depots and Blood Serum as Promising Biomarkers of Cardiovascular Diseases Neurogenetics of Brain Connectivity: Current Approaches to the Study (Review) Brain–Computer Interfaces with Intracortical Implants for Motor and Communication Functions Compensation: Review of Recent Developments Evaluation of the Feasibility of Using Commercial Wound Coatings as a Carrier Matrix for Bacteriophages Performance of the Models Predicting In-Hospital Mortality in Patients with ST-Segment Elevation Myocardial Infarction with Predictors in Categorical and Continuous Forms
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1