{"title":"利用动态电压恢复器(dvr)减轻电压偏差对delsuth医疗机构的影响","authors":"Umukoro Arieyeri Patrick, P. Oshevi̇re","doi":"10.29081/jesr.v28i3.011","DOIUrl":null,"url":null,"abstract":"This paper examined power supply at DELSUTH with the aim of mitigating effects of voltage deviation. The 11KV feeder from 7.5MVA substation which supplies the Hospital was analyzed using Dynamic Voltage Restorer (DVR) device on ETAP 16.0 software environment. It was observed that load flow analysis is vital in understanding the operating nature of the network, by considering the reactive power, voltage deviation magnitude and power losses in the network. From the simulation there was low voltage profile in the transformers feeding the clinical area. The voltage profile was improved by upgrading the network to standard power factor.","PeriodicalId":15687,"journal":{"name":"Journal of Engineering Studies and Research","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"MITIGATING EFFECTS OF VOLTAGE DEVIATION ON DELSUTH HEALTH CARE FACILITY UTILIZING DYNAMIC VOLTAGE RESTORER (DVR)\",\"authors\":\"Umukoro Arieyeri Patrick, P. Oshevi̇re\",\"doi\":\"10.29081/jesr.v28i3.011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper examined power supply at DELSUTH with the aim of mitigating effects of voltage deviation. The 11KV feeder from 7.5MVA substation which supplies the Hospital was analyzed using Dynamic Voltage Restorer (DVR) device on ETAP 16.0 software environment. It was observed that load flow analysis is vital in understanding the operating nature of the network, by considering the reactive power, voltage deviation magnitude and power losses in the network. From the simulation there was low voltage profile in the transformers feeding the clinical area. The voltage profile was improved by upgrading the network to standard power factor.\",\"PeriodicalId\":15687,\"journal\":{\"name\":\"Journal of Engineering Studies and Research\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Engineering Studies and Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29081/jesr.v28i3.011\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering Studies and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29081/jesr.v28i3.011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
MITIGATING EFFECTS OF VOLTAGE DEVIATION ON DELSUTH HEALTH CARE FACILITY UTILIZING DYNAMIC VOLTAGE RESTORER (DVR)
This paper examined power supply at DELSUTH with the aim of mitigating effects of voltage deviation. The 11KV feeder from 7.5MVA substation which supplies the Hospital was analyzed using Dynamic Voltage Restorer (DVR) device on ETAP 16.0 software environment. It was observed that load flow analysis is vital in understanding the operating nature of the network, by considering the reactive power, voltage deviation magnitude and power losses in the network. From the simulation there was low voltage profile in the transformers feeding the clinical area. The voltage profile was improved by upgrading the network to standard power factor.