Andrew Canakis, Saurabh Chandan, Jay Bapaye, Justin Canakis, Benjamin Twery, Babu P Mohan, Daryl Ramai, Antonio Facciorusso, Mohammad Bilal, Douglas G Adler
{"title":"小(<10毫米)带蒂结直肠息肉的冷陷阱息肉切除术","authors":"Andrew Canakis, Saurabh Chandan, Jay Bapaye, Justin Canakis, Benjamin Twery, Babu P Mohan, Daryl Ramai, Antonio Facciorusso, Mohammad Bilal, Douglas G Adler","doi":"10.1097/MCG.0000000000001848","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Endoscopic removal techniques for colorectal polyps include cold snare polypectomy (CSP) and hot snare polypectomy (HSP). Although HSP is recommended for pedunculated polyps (PPs) larger than 10 mm, data regarding use of CSP for PPs <10 mm continues to emerge. We aimed to investigate outcomes of these techniques in small (<10 mm) pedunculated colorectal polyps.</p><p><strong>Methods: </strong>Multiple databases were searched till June 2022 to identify studies involving the removal of small PPs with CSP and HSP. Random effects model was used to calculate outcomes and 95% CI. Primary outcome was the pooled rate of successful en-bloc resection. Secondary outcomes were immediate and delayed bleeding with CSP and HSP as well as prophylactic and post resection clip placement.</p><p><strong>Results: </strong>Six studies including 1025 patients (1111 polyps with a mean size 4 to 8.5 mm) were analyzed. 116 and 995 polyps were removed with HSP and CSP, respectively. The overall pooled rate of successful en-bloc resection with CSP was 99.7% (CI 99.1-99.9; I2 0%). Pooled immediate and delayed bleeding after CSP was 49.8% (CI 46.8-52.91; I2 98%) and 0% (CI 0.00-0.00; I2 0%), respectively. Delayed bleeding was higher with HSP, relative risk 0.05 (CI 0.01-0.43; I2 0%), P =0.006, whereas immediate bleeding was higher with CSP, relative risk 7.89 (CI 4.36-14.29; I2 0%), P <0.00001. Pooled rates of prophylactic clip placement and post-procedure clip placement (to control immediate bleeding) were 55.3% and 47.2%, respectively. Finally, right colon polyp location significantly correlated with frequency of immediate bleeding.</p><p><strong>Conclusion: </strong>Our analysis shows that CSP is safe and effective for resection of small PPs.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"370-377"},"PeriodicalIF":4.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cold Snare Polypectomy in Small (<10 mm) Pedunculated Colorectal Polyps: A Systematic Review and Meta-analysis.\",\"authors\":\"Andrew Canakis, Saurabh Chandan, Jay Bapaye, Justin Canakis, Benjamin Twery, Babu P Mohan, Daryl Ramai, Antonio Facciorusso, Mohammad Bilal, Douglas G Adler\",\"doi\":\"10.1097/MCG.0000000000001848\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Endoscopic removal techniques for colorectal polyps include cold snare polypectomy (CSP) and hot snare polypectomy (HSP). Although HSP is recommended for pedunculated polyps (PPs) larger than 10 mm, data regarding use of CSP for PPs <10 mm continues to emerge. We aimed to investigate outcomes of these techniques in small (<10 mm) pedunculated colorectal polyps.</p><p><strong>Methods: </strong>Multiple databases were searched till June 2022 to identify studies involving the removal of small PPs with CSP and HSP. Random effects model was used to calculate outcomes and 95% CI. Primary outcome was the pooled rate of successful en-bloc resection. Secondary outcomes were immediate and delayed bleeding with CSP and HSP as well as prophylactic and post resection clip placement.</p><p><strong>Results: </strong>Six studies including 1025 patients (1111 polyps with a mean size 4 to 8.5 mm) were analyzed. 116 and 995 polyps were removed with HSP and CSP, respectively. The overall pooled rate of successful en-bloc resection with CSP was 99.7% (CI 99.1-99.9; I2 0%). Pooled immediate and delayed bleeding after CSP was 49.8% (CI 46.8-52.91; I2 98%) and 0% (CI 0.00-0.00; I2 0%), respectively. Delayed bleeding was higher with HSP, relative risk 0.05 (CI 0.01-0.43; I2 0%), P =0.006, whereas immediate bleeding was higher with CSP, relative risk 7.89 (CI 4.36-14.29; I2 0%), P <0.00001. Pooled rates of prophylactic clip placement and post-procedure clip placement (to control immediate bleeding) were 55.3% and 47.2%, respectively. Finally, right colon polyp location significantly correlated with frequency of immediate bleeding.</p><p><strong>Conclusion: </strong>Our analysis shows that CSP is safe and effective for resection of small PPs.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":\" \",\"pages\":\"370-377\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/MCG.0000000000001848\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/MCG.0000000000001848","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Cold Snare Polypectomy in Small (<10 mm) Pedunculated Colorectal Polyps: A Systematic Review and Meta-analysis.
Introduction: Endoscopic removal techniques for colorectal polyps include cold snare polypectomy (CSP) and hot snare polypectomy (HSP). Although HSP is recommended for pedunculated polyps (PPs) larger than 10 mm, data regarding use of CSP for PPs <10 mm continues to emerge. We aimed to investigate outcomes of these techniques in small (<10 mm) pedunculated colorectal polyps.
Methods: Multiple databases were searched till June 2022 to identify studies involving the removal of small PPs with CSP and HSP. Random effects model was used to calculate outcomes and 95% CI. Primary outcome was the pooled rate of successful en-bloc resection. Secondary outcomes were immediate and delayed bleeding with CSP and HSP as well as prophylactic and post resection clip placement.
Results: Six studies including 1025 patients (1111 polyps with a mean size 4 to 8.5 mm) were analyzed. 116 and 995 polyps were removed with HSP and CSP, respectively. The overall pooled rate of successful en-bloc resection with CSP was 99.7% (CI 99.1-99.9; I2 0%). Pooled immediate and delayed bleeding after CSP was 49.8% (CI 46.8-52.91; I2 98%) and 0% (CI 0.00-0.00; I2 0%), respectively. Delayed bleeding was higher with HSP, relative risk 0.05 (CI 0.01-0.43; I2 0%), P =0.006, whereas immediate bleeding was higher with CSP, relative risk 7.89 (CI 4.36-14.29; I2 0%), P <0.00001. Pooled rates of prophylactic clip placement and post-procedure clip placement (to control immediate bleeding) were 55.3% and 47.2%, respectively. Finally, right colon polyp location significantly correlated with frequency of immediate bleeding.
Conclusion: Our analysis shows that CSP is safe and effective for resection of small PPs.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.