{"title":"基于人工神经网络的上流式厌氧固定床生物反应器工业污水处理厂模拟","authors":"Kobra Verijkazemi, R. Jalilzadeh Yengejeh","doi":"10.34172/ajehe.2022.01","DOIUrl":null,"url":null,"abstract":"Given the variable nature of industrial wastewaters, the appropriate operation of an industrial wastewater treatment plant (WWTP) is a prerequisite for keeping process stability at ideal conditions. In this respect, an artificial neural network (ANN) can be a powerful device for the prediction of treatment performance. This study assessed some qualitative parameters of industrial wastewater (Amol Industrial Estate) during a one-year operating period. The wastewater treatment process consisted of an equalization tank, up-flow anaerobic fixed bed (UAFB) bioreactor, activated sludge tank, sedimentation tank, and chlorination basin. The ANN was utilized to estimate the system efficiency of the UAFB process. The outcomes demonstrated an extraordinary arrangement between the real and simulated data (R2>0.8). This model supplied a proper device for forecasting the implementation of WWTPs. Continuous checking elements could be used for the simulation of wastewater specifications.","PeriodicalId":8672,"journal":{"name":"Avicenna Journal of Environmental Health Engineering","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Simulation of an Industrial Wastewater Treatment Plant by Up-flow Anaerobic Fixed Bed Bioreactor Based on an Artificial Neural Network\",\"authors\":\"Kobra Verijkazemi, R. Jalilzadeh Yengejeh\",\"doi\":\"10.34172/ajehe.2022.01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Given the variable nature of industrial wastewaters, the appropriate operation of an industrial wastewater treatment plant (WWTP) is a prerequisite for keeping process stability at ideal conditions. In this respect, an artificial neural network (ANN) can be a powerful device for the prediction of treatment performance. This study assessed some qualitative parameters of industrial wastewater (Amol Industrial Estate) during a one-year operating period. The wastewater treatment process consisted of an equalization tank, up-flow anaerobic fixed bed (UAFB) bioreactor, activated sludge tank, sedimentation tank, and chlorination basin. The ANN was utilized to estimate the system efficiency of the UAFB process. The outcomes demonstrated an extraordinary arrangement between the real and simulated data (R2>0.8). This model supplied a proper device for forecasting the implementation of WWTPs. Continuous checking elements could be used for the simulation of wastewater specifications.\",\"PeriodicalId\":8672,\"journal\":{\"name\":\"Avicenna Journal of Environmental Health Engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Avicenna Journal of Environmental Health Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34172/ajehe.2022.01\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Avicenna Journal of Environmental Health Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/ajehe.2022.01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Environmental Science","Score":null,"Total":0}
Simulation of an Industrial Wastewater Treatment Plant by Up-flow Anaerobic Fixed Bed Bioreactor Based on an Artificial Neural Network
Given the variable nature of industrial wastewaters, the appropriate operation of an industrial wastewater treatment plant (WWTP) is a prerequisite for keeping process stability at ideal conditions. In this respect, an artificial neural network (ANN) can be a powerful device for the prediction of treatment performance. This study assessed some qualitative parameters of industrial wastewater (Amol Industrial Estate) during a one-year operating period. The wastewater treatment process consisted of an equalization tank, up-flow anaerobic fixed bed (UAFB) bioreactor, activated sludge tank, sedimentation tank, and chlorination basin. The ANN was utilized to estimate the system efficiency of the UAFB process. The outcomes demonstrated an extraordinary arrangement between the real and simulated data (R2>0.8). This model supplied a proper device for forecasting the implementation of WWTPs. Continuous checking elements could be used for the simulation of wastewater specifications.