Ting-Yuan Feng, Sheng-Chun Wang, G. Liao, Teng‐Wei Chen, D. Chan, K. Hsu
{"title":"可吸收多金属夹与金属夹在腹腔镜阑尾切除术中的比较","authors":"Ting-Yuan Feng, Sheng-Chun Wang, G. Liao, Teng‐Wei Chen, D. Chan, K. Hsu","doi":"10.4103/jmedsci.jmedsci_372_21","DOIUrl":null,"url":null,"abstract":"Background: Laparoscopic appendectomy is the most common emergent surgery, and various techniques were used for the closure of appendicular stump and appendiceal artery. Aim: This study aimed to compare the clinical impacts of absorbable polymeric clips and traditional metallic clips. Methods: We reviewed the laparoscopic appendectomies performed from June 2020 to May 2021 in a medical center. We analyzed the characteristics and intraoperative and postoperative data of patients receiving absorbable or metallic clips during laparoscopic appendectomy. Results: A total of 120 patients were enrolled in this study. Fifty-nine patients received lapro-clips for the ligation of appendicular stump and artery (Group A), whereas 61 patients received titanium clips (Group B). The operative time for both groups was 63.6 ± 18.9 min and 65.5 ± 19.2 min, respectively (P ɢ.586). There was no significant difference in postoperative complications (P = 0.958). The length of hospital stay for each group was 3.07 ± 1.14 days and 2.90 ± 1.18 days, respectively (P = 0.435). Conclusion: The application of absorbable polymetric clips is feasible and safe with the additional benefit of leaving no foreign body for the closure of appendicular stump and ligation of appendiceal artery for laparoscopic appendectomy.","PeriodicalId":39900,"journal":{"name":"Journal of Medical Sciences (Taiwan)","volume":"43 1","pages":"63 - 66"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comparison of absorbable polymetric clips and metallic clips in laparoscopic appendectomy\",\"authors\":\"Ting-Yuan Feng, Sheng-Chun Wang, G. Liao, Teng‐Wei Chen, D. Chan, K. Hsu\",\"doi\":\"10.4103/jmedsci.jmedsci_372_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Laparoscopic appendectomy is the most common emergent surgery, and various techniques were used for the closure of appendicular stump and appendiceal artery. Aim: This study aimed to compare the clinical impacts of absorbable polymeric clips and traditional metallic clips. Methods: We reviewed the laparoscopic appendectomies performed from June 2020 to May 2021 in a medical center. We analyzed the characteristics and intraoperative and postoperative data of patients receiving absorbable or metallic clips during laparoscopic appendectomy. Results: A total of 120 patients were enrolled in this study. Fifty-nine patients received lapro-clips for the ligation of appendicular stump and artery (Group A), whereas 61 patients received titanium clips (Group B). The operative time for both groups was 63.6 ± 18.9 min and 65.5 ± 19.2 min, respectively (P ɢ.586). There was no significant difference in postoperative complications (P = 0.958). The length of hospital stay for each group was 3.07 ± 1.14 days and 2.90 ± 1.18 days, respectively (P = 0.435). Conclusion: The application of absorbable polymetric clips is feasible and safe with the additional benefit of leaving no foreign body for the closure of appendicular stump and ligation of appendiceal artery for laparoscopic appendectomy.\",\"PeriodicalId\":39900,\"journal\":{\"name\":\"Journal of Medical Sciences (Taiwan)\",\"volume\":\"43 1\",\"pages\":\"63 - 66\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Sciences (Taiwan)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jmedsci.jmedsci_372_21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Sciences (Taiwan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jmedsci.jmedsci_372_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
摘要
背景:腹腔镜阑尾切除术是最常见的急诊手术,阑尾残端及阑尾动脉的闭合采用多种技术。目的:比较可吸收聚合物夹与传统金属夹的临床效果。方法:回顾2020年6月至2021年5月在某医疗中心进行的腹腔镜阑尾切除术。我们分析了在腹腔镜阑尾切除术中使用可吸收夹或金属夹的患者的特点和术中、术后资料。结果:本研究共纳入120例患者。A组59例使用拉普夹结扎阑尾残端及动脉,B组61例使用钛夹结扎,两组手术时间分别为63.6±18.9 min和65.5±19.2 min (P < 0.05)。两组术后并发症发生率差异无统计学意义(P = 0.958)。两组患者住院时间分别为3.07±1.14天和2.90±1.18天(P = 0.435)。结论:在腹腔镜阑尾切除术中,应用可吸收性多聚夹进行阑尾残端闭合和阑尾动脉结扎,具有无异物的优点,是可行和安全的。
A comparison of absorbable polymetric clips and metallic clips in laparoscopic appendectomy
Background: Laparoscopic appendectomy is the most common emergent surgery, and various techniques were used for the closure of appendicular stump and appendiceal artery. Aim: This study aimed to compare the clinical impacts of absorbable polymeric clips and traditional metallic clips. Methods: We reviewed the laparoscopic appendectomies performed from June 2020 to May 2021 in a medical center. We analyzed the characteristics and intraoperative and postoperative data of patients receiving absorbable or metallic clips during laparoscopic appendectomy. Results: A total of 120 patients were enrolled in this study. Fifty-nine patients received lapro-clips for the ligation of appendicular stump and artery (Group A), whereas 61 patients received titanium clips (Group B). The operative time for both groups was 63.6 ± 18.9 min and 65.5 ± 19.2 min, respectively (P ɢ.586). There was no significant difference in postoperative complications (P = 0.958). The length of hospital stay for each group was 3.07 ± 1.14 days and 2.90 ± 1.18 days, respectively (P = 0.435). Conclusion: The application of absorbable polymetric clips is feasible and safe with the additional benefit of leaving no foreign body for the closure of appendicular stump and ligation of appendiceal artery for laparoscopic appendectomy.