M. Ochowiak, A. Krupińska, S. Włodarczak, M. Matuszak, Patrycja Zielińska, K. Czernek, S. Witczak, T. Wilk
{"title":"泡沫水喷嘴产生的喷雾流中的压降、喷射角和喷射强度分布分析","authors":"M. Ochowiak, A. Krupińska, S. Włodarczak, M. Matuszak, Patrycja Zielińska, K. Czernek, S. Witczak, T. Wilk","doi":"10.2478/pjct-2022-0013","DOIUrl":null,"url":null,"abstract":"Abstract This paper summarises a series of large-scale fire suppression tests conducted to simulate a fire in the big surface and/or surface sprinkling. The subject of this paper is the research on water spraying with the use of the Turbo Jet 2011 water-foam nozzle manufactured by Supon Białystok. The results discuss the pressure losses caused by the flow through the discharge hose, spray angle, and the intensity of surface sprinkling. The greatest stream ranges and the highest maximum values of the sprinkling intensity were obtained at the capacity of 400 l/min, and a solid spray angle. The smallest values were obtained at 200 l/min, a pressure of 5 bar, and a solid spray angle. The actual pressures taking into account the losses in the hose section were calculated. As for the highest firefighting effectiveness of the stream, the authors recommended the following parameters: semi spray angle, 200 l/min, and 2.5 bar.","PeriodicalId":20324,"journal":{"name":"Polish Journal of Chemical Technology","volume":"24 1","pages":"42 - 49"},"PeriodicalIF":0.7000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The analysis of pressure drop, spray angle, and sprinkling intensity distribution in the spray stream produced by the water-foam nozzle\",\"authors\":\"M. Ochowiak, A. Krupińska, S. Włodarczak, M. Matuszak, Patrycja Zielińska, K. Czernek, S. Witczak, T. Wilk\",\"doi\":\"10.2478/pjct-2022-0013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This paper summarises a series of large-scale fire suppression tests conducted to simulate a fire in the big surface and/or surface sprinkling. The subject of this paper is the research on water spraying with the use of the Turbo Jet 2011 water-foam nozzle manufactured by Supon Białystok. The results discuss the pressure losses caused by the flow through the discharge hose, spray angle, and the intensity of surface sprinkling. The greatest stream ranges and the highest maximum values of the sprinkling intensity were obtained at the capacity of 400 l/min, and a solid spray angle. The smallest values were obtained at 200 l/min, a pressure of 5 bar, and a solid spray angle. The actual pressures taking into account the losses in the hose section were calculated. As for the highest firefighting effectiveness of the stream, the authors recommended the following parameters: semi spray angle, 200 l/min, and 2.5 bar.\",\"PeriodicalId\":20324,\"journal\":{\"name\":\"Polish Journal of Chemical Technology\",\"volume\":\"24 1\",\"pages\":\"42 - 49\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2022-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Chemical Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2478/pjct-2022-0013\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Chemical Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2478/pjct-2022-0013","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
The analysis of pressure drop, spray angle, and sprinkling intensity distribution in the spray stream produced by the water-foam nozzle
Abstract This paper summarises a series of large-scale fire suppression tests conducted to simulate a fire in the big surface and/or surface sprinkling. The subject of this paper is the research on water spraying with the use of the Turbo Jet 2011 water-foam nozzle manufactured by Supon Białystok. The results discuss the pressure losses caused by the flow through the discharge hose, spray angle, and the intensity of surface sprinkling. The greatest stream ranges and the highest maximum values of the sprinkling intensity were obtained at the capacity of 400 l/min, and a solid spray angle. The smallest values were obtained at 200 l/min, a pressure of 5 bar, and a solid spray angle. The actual pressures taking into account the losses in the hose section were calculated. As for the highest firefighting effectiveness of the stream, the authors recommended the following parameters: semi spray angle, 200 l/min, and 2.5 bar.
期刊介绍:
Polish Journal of Chemical Technology is a peer-reviewed, international journal devoted to fundamental and applied chemistry, as well as chemical engineering and biotechnology research. It has a very broad scope but favors interdisciplinary research that bring chemical technology together with other disciplines. All authors receive very fast and comprehensive peer-review. Additionally, every published article is promoted to researchers working in the same field.