{"title":"高灵敏度聚合物传感器测定药物米托蒽醌","authors":"J. G. Manjunatha","doi":"10.18311/JSST/2018/15838","DOIUrl":null,"url":null,"abstract":"A carbon paste electrode modified with electropolymerization of glycine exhibited an attractive performance for the detection and determination of a anticancer drug, Mitoxantrone (MTX). Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV) were used in a combined way to identify the electrochemical characteristics and to optimize the conditions for detection of MTX. The electrochemical behaviour of MTX was investigated and a well-defined oxidation peak with high sensitivity was observed at the film electrode. Poly (Glycine) Modified Carbon Paste Electrode (PGMCPE) greatly enhanced the oxidation peak current of MTX owing to the extraordinary properties of glycine film. Based on this, a sensitive and simple voltammetric method was developed for measurement of MTX. A sensitive linear voltammetric response for MTX was obtained in the concentration range of 4×10 −8 -1×10 -5 mol/L, detection limit was 3.2×10 −7 M and quantification limit was 10×10 −7 M using CV. The proposed method possessed advantages such as low detection limit, fast response, low cost and simplicity.","PeriodicalId":17031,"journal":{"name":"Journal of Surface Science and Technology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Highly Sensitive Polymer based Sensor for Determination of the Drug Mitoxantrone\",\"authors\":\"J. G. Manjunatha\",\"doi\":\"10.18311/JSST/2018/15838\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A carbon paste electrode modified with electropolymerization of glycine exhibited an attractive performance for the detection and determination of a anticancer drug, Mitoxantrone (MTX). Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV) were used in a combined way to identify the electrochemical characteristics and to optimize the conditions for detection of MTX. The electrochemical behaviour of MTX was investigated and a well-defined oxidation peak with high sensitivity was observed at the film electrode. Poly (Glycine) Modified Carbon Paste Electrode (PGMCPE) greatly enhanced the oxidation peak current of MTX owing to the extraordinary properties of glycine film. Based on this, a sensitive and simple voltammetric method was developed for measurement of MTX. A sensitive linear voltammetric response for MTX was obtained in the concentration range of 4×10 −8 -1×10 -5 mol/L, detection limit was 3.2×10 −7 M and quantification limit was 10×10 −7 M using CV. The proposed method possessed advantages such as low detection limit, fast response, low cost and simplicity.\",\"PeriodicalId\":17031,\"journal\":{\"name\":\"Journal of Surface Science and Technology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Surface Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18311/JSST/2018/15838\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Materials Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Surface Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18311/JSST/2018/15838","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Materials Science","Score":null,"Total":0}
Highly Sensitive Polymer based Sensor for Determination of the Drug Mitoxantrone
A carbon paste electrode modified with electropolymerization of glycine exhibited an attractive performance for the detection and determination of a anticancer drug, Mitoxantrone (MTX). Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV) were used in a combined way to identify the electrochemical characteristics and to optimize the conditions for detection of MTX. The electrochemical behaviour of MTX was investigated and a well-defined oxidation peak with high sensitivity was observed at the film electrode. Poly (Glycine) Modified Carbon Paste Electrode (PGMCPE) greatly enhanced the oxidation peak current of MTX owing to the extraordinary properties of glycine film. Based on this, a sensitive and simple voltammetric method was developed for measurement of MTX. A sensitive linear voltammetric response for MTX was obtained in the concentration range of 4×10 −8 -1×10 -5 mol/L, detection limit was 3.2×10 −7 M and quantification limit was 10×10 −7 M using CV. The proposed method possessed advantages such as low detection limit, fast response, low cost and simplicity.
期刊介绍:
The Indian Society for Surface Science and Technology is an organization for the cultivation, interaction and dissemination of knowledge in the field of surface science and technology. It also strives to promote Industry-Academia interaction