数字反符合计数法在59Fe初度测定中的应用

IF 0.6 Q4 NUCLEAR SCIENCE & TECHNOLOGY Atom Indonesia Pub Date : 2019-08-30 DOI:10.17146/aij.2019.812
A. Agusbudiman, K. B. Lee, J. M. Lee
{"title":"数字反符合计数法在59Fe初度测定中的应用","authors":"A. Agusbudiman, K. B. Lee, J. M. Lee","doi":"10.17146/aij.2019.812","DOIUrl":null,"url":null,"abstract":"As a radiopharmaceutical, the use of 59 Fe is classified as a high pharmaceutical risk product. Therefore, a standard reference for activity measurement of 59 Fe is necessary to ensure its metrological aspect. This paper describes an alternative method for primary activity determination of 59 Fe for establishing a standard reference. The 59 Fe solution was prepared using two different cocktails and measured by the 4 p b (LS)- g counting system using a digital anti-coincidence counting method with emulated live-time of the extending dead-time. A final activity results at the reference time for the two samples series are (473.32 ± 2.55) kBq/g and (477.14 ± 2.42) kBq/g with quoted uncertainty evaluated at k = 1. The final activity was compared to the value obtained from the other two coincidence counting method and found to be in a good agreement within its uncertainty value.","PeriodicalId":8647,"journal":{"name":"Atom Indonesia","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2019-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of Digital Anti-Coincidence Counting Method for Primary Activity Determination of 59Fe\",\"authors\":\"A. Agusbudiman, K. B. Lee, J. M. Lee\",\"doi\":\"10.17146/aij.2019.812\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As a radiopharmaceutical, the use of 59 Fe is classified as a high pharmaceutical risk product. Therefore, a standard reference for activity measurement of 59 Fe is necessary to ensure its metrological aspect. This paper describes an alternative method for primary activity determination of 59 Fe for establishing a standard reference. The 59 Fe solution was prepared using two different cocktails and measured by the 4 p b (LS)- g counting system using a digital anti-coincidence counting method with emulated live-time of the extending dead-time. A final activity results at the reference time for the two samples series are (473.32 ± 2.55) kBq/g and (477.14 ± 2.42) kBq/g with quoted uncertainty evaluated at k = 1. The final activity was compared to the value obtained from the other two coincidence counting method and found to be in a good agreement within its uncertainty value.\",\"PeriodicalId\":8647,\"journal\":{\"name\":\"Atom Indonesia\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2019-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atom Indonesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17146/aij.2019.812\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atom Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17146/aij.2019.812","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

作为一种放射性药物,59Fe的使用被归类为高药物风险产品。因此,有必要为59Fe的活度测量提供一个标准参考,以确保其计量方面。本文介绍了一种测定59Fe一次活度的替代方法,以建立标准参考。使用两种不同的混合物制备59Fe溶液,并通过4 PB(LS)-g计数系统使用数字反重合计数方法进行测量,模拟了延长死区的活时间。两个样品系列在参考时间的最终活度结果分别为(473.32±2.55)kBq/g和(477.14±2.42)kBq/g,引用的不确定度在k=1时进行评估。将最终活度与从其他两种符合计数方法获得的值进行比较,发现在其不确定度值范围内非常一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Application of Digital Anti-Coincidence Counting Method for Primary Activity Determination of 59Fe
As a radiopharmaceutical, the use of 59 Fe is classified as a high pharmaceutical risk product. Therefore, a standard reference for activity measurement of 59 Fe is necessary to ensure its metrological aspect. This paper describes an alternative method for primary activity determination of 59 Fe for establishing a standard reference. The 59 Fe solution was prepared using two different cocktails and measured by the 4 p b (LS)- g counting system using a digital anti-coincidence counting method with emulated live-time of the extending dead-time. A final activity results at the reference time for the two samples series are (473.32 ± 2.55) kBq/g and (477.14 ± 2.42) kBq/g with quoted uncertainty evaluated at k = 1. The final activity was compared to the value obtained from the other two coincidence counting method and found to be in a good agreement within its uncertainty value.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Atom Indonesia
Atom Indonesia NUCLEAR SCIENCE & TECHNOLOGY-
CiteScore
1.00
自引率
0.00%
发文量
20
审稿时长
16 weeks
期刊介绍: The focus of Atom Indonesia is research and development in nuclear science and technology. The scope of this journal covers experimental and analytical research in nuclear science and technology. The topics include nuclear physics, reactor physics, radioactive waste, fuel element, radioisotopes, radiopharmacy, radiation, and neutron scattering, as well as their utilization in agriculture, industry, health, environment, energy, material science and technology, and related fields.
期刊最新文献
External Bremsstrahlung Studies on Films of Lead Monoxide Filled Polycarbonate Composite Radon Concentration in Urban Areas in the North and West of Morocco Geologic Influence on Radon Concentrations Levels in Cave: A Case Study of Mimpi Cave in the Maros Karst of South Sulawesi, Indonesia Elemental Mapping and Quantities in Different Soybean Seed Colors Using Micro X-Ray Fluorescence and Their Correlations with Germination Assessment of 137Cs in the Environment of Hetauda City, Nepal by In-Situ Gamma Ray Spectrometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1