喉罩插管与纤维支气管镜插管在预期困难气道中的比较评价:一项随机对照研究

IF 0.2 Q4 ANESTHESIOLOGY Indian Anaesthetists Forum Pub Date : 2022-07-01 DOI:10.4103/TheIAForum.TheIAForum_37_22
Neelakshi Koul, V. Dhir, N. Choudhary, J. Singh, Deepak Nohwar, Mohandeep Kaur
{"title":"喉罩插管与纤维支气管镜插管在预期困难气道中的比较评价:一项随机对照研究","authors":"Neelakshi Koul, V. Dhir, N. Choudhary, J. Singh, Deepak Nohwar, Mohandeep Kaur","doi":"10.4103/TheIAForum.TheIAForum_37_22","DOIUrl":null,"url":null,"abstract":"Background: Management of difficult airway remains a cornerstone of anesthesiology requiring constant probe into newer devices challenging set gold standards. Hence, we compared the effectiveness of intubating laryngeal mask airway (ILMA) with flexible fiberoptic bronchoscope (FOB) in anticipated difficult airway. Aims: The aim of this study was to compare and evaluate ILMA and FOB for tracheal intubation in patients with anticipated difficult airway. Settings and Design: The study design involves comparative randomized study. Materials and Methods: Fifty patients undergoing elective surgery under general anesthesia with anticipated difficult airway (Modified Mallampati Class III/Wilson's Score 6-7) were divided into Group I (ILMA) and Group F (FOB). Primary outcomes, i.e., ease of intubation (number and duration of attempts) and success rate; and secondary outcomes, i.e., hemodynamic parameters and adverse events were noted. Results: Both the groups were comparable in age, gender distribution, body mass index, and type of surgery. The number of attempts required and hemodynamics changes were similar in both groups. ILMA required lesser time, i.e., 59.76 s versus FOB, i.e., 109.88 s in the first attempt (DA1) and 62.67 s for Group I versus 120.86 s for Group F in the second attempt (DA2), being statistically significant. ILMA showed higher adverse event rate versus FOB; however, the difference was statistically insignificant. Conclusions: ILMA is an effective alternative to FOB in patients with anticipated difficult airway with respect to ease of intubation, with similar hemodynamic stability, success rate, and adverse events. Anticipated difficult airway, fiberoptic bronchoscope, intubating laryngeal mask airway","PeriodicalId":42359,"journal":{"name":"Indian Anaesthetists Forum","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative evaluation of intubating laryngeal mask airway with fiberoptic bronchoscopic intubation in anticipated difficult airway: A randomized controlled study\",\"authors\":\"Neelakshi Koul, V. Dhir, N. Choudhary, J. Singh, Deepak Nohwar, Mohandeep Kaur\",\"doi\":\"10.4103/TheIAForum.TheIAForum_37_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Management of difficult airway remains a cornerstone of anesthesiology requiring constant probe into newer devices challenging set gold standards. Hence, we compared the effectiveness of intubating laryngeal mask airway (ILMA) with flexible fiberoptic bronchoscope (FOB) in anticipated difficult airway. Aims: The aim of this study was to compare and evaluate ILMA and FOB for tracheal intubation in patients with anticipated difficult airway. Settings and Design: The study design involves comparative randomized study. Materials and Methods: Fifty patients undergoing elective surgery under general anesthesia with anticipated difficult airway (Modified Mallampati Class III/Wilson's Score 6-7) were divided into Group I (ILMA) and Group F (FOB). Primary outcomes, i.e., ease of intubation (number and duration of attempts) and success rate; and secondary outcomes, i.e., hemodynamic parameters and adverse events were noted. Results: Both the groups were comparable in age, gender distribution, body mass index, and type of surgery. The number of attempts required and hemodynamics changes were similar in both groups. ILMA required lesser time, i.e., 59.76 s versus FOB, i.e., 109.88 s in the first attempt (DA1) and 62.67 s for Group I versus 120.86 s for Group F in the second attempt (DA2), being statistically significant. ILMA showed higher adverse event rate versus FOB; however, the difference was statistically insignificant. Conclusions: ILMA is an effective alternative to FOB in patients with anticipated difficult airway with respect to ease of intubation, with similar hemodynamic stability, success rate, and adverse events. Anticipated difficult airway, fiberoptic bronchoscope, intubating laryngeal mask airway\",\"PeriodicalId\":42359,\"journal\":{\"name\":\"Indian Anaesthetists Forum\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Anaesthetists Forum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/TheIAForum.TheIAForum_37_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Anaesthetists Forum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/TheIAForum.TheIAForum_37_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:气道困难的管理仍然是麻醉学的基石,需要不断探索具有挑战性的新设备。因此,我们比较了喉罩气道(ILMA)和柔性纤维支气管镜(FOB)在预期困难气道中的插管效果。目的:本研究的目的是比较和评估ILMA和FOB在预期气道困难患者气管插管中的作用。设置和设计:研究设计包括比较随机研究。材料和方法:将50例在全麻下接受择期手术的患者分为I组(ILMA)和F组(FOB)。主要结果,即插管的容易程度(尝试次数和持续时间)和成功率;次要结果,即血液动力学参数和不良事件。结果:两组在年龄、性别分布、体重指数和手术类型方面具有可比性。两组所需的尝试次数和血流动力学变化相似。ILMA需要较少的时间,即与FOB相比,59.76 s,即第一次尝试(DA1)为109.88 s,i组为62.67 s,而F组为120.86 s,具有统计学意义。ILMA的不良事件发生率高于FOB;然而,这一差异在统计学上并不显著。结论:对于预期气道困难的患者,ILMA是一种有效的替代FOB的方法,其插管容易,具有相似的血液动力学稳定性、成功率和不良事件。预期困难气道、纤维支气管镜、插管喉罩气道
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative evaluation of intubating laryngeal mask airway with fiberoptic bronchoscopic intubation in anticipated difficult airway: A randomized controlled study
Background: Management of difficult airway remains a cornerstone of anesthesiology requiring constant probe into newer devices challenging set gold standards. Hence, we compared the effectiveness of intubating laryngeal mask airway (ILMA) with flexible fiberoptic bronchoscope (FOB) in anticipated difficult airway. Aims: The aim of this study was to compare and evaluate ILMA and FOB for tracheal intubation in patients with anticipated difficult airway. Settings and Design: The study design involves comparative randomized study. Materials and Methods: Fifty patients undergoing elective surgery under general anesthesia with anticipated difficult airway (Modified Mallampati Class III/Wilson's Score 6-7) were divided into Group I (ILMA) and Group F (FOB). Primary outcomes, i.e., ease of intubation (number and duration of attempts) and success rate; and secondary outcomes, i.e., hemodynamic parameters and adverse events were noted. Results: Both the groups were comparable in age, gender distribution, body mass index, and type of surgery. The number of attempts required and hemodynamics changes were similar in both groups. ILMA required lesser time, i.e., 59.76 s versus FOB, i.e., 109.88 s in the first attempt (DA1) and 62.67 s for Group I versus 120.86 s for Group F in the second attempt (DA2), being statistically significant. ILMA showed higher adverse event rate versus FOB; however, the difference was statistically insignificant. Conclusions: ILMA is an effective alternative to FOB in patients with anticipated difficult airway with respect to ease of intubation, with similar hemodynamic stability, success rate, and adverse events. Anticipated difficult airway, fiberoptic bronchoscope, intubating laryngeal mask airway
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Anaesthetists Forum
Indian Anaesthetists Forum ANESTHESIOLOGY-
自引率
0.00%
发文量
17
审稿时长
6 weeks
期刊最新文献
Cardiovascular complications in coronavirus disease-2019 patients Refractory hypokalemia in intensive care unit: Efforts in vain Evaluation of effect of dexamethasone and bicarbonate as adjuvants to intracuff lignocaine on endotracheal tube tolerance during emergence and incidence of postoperative cough and sore throat Is it popliteal artery? Is it popliteal vein? No it is persistent sciatic vein Mortality predictors during the third wave of COVID-19 pandemic: A multicentric retrospective analysis from tertiary care centers of Western India
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1