点温度测量用液晶复合材料

Edyta Prusińska-Kurstak, K. Garbat, A. Kołakowska, S. Kłosowicz
{"title":"点温度测量用液晶复合材料","authors":"Edyta Prusińska-Kurstak, K. Garbat, A. Kołakowska, S. Kłosowicz","doi":"10.5604/01.3001.0010.1886","DOIUrl":null,"url":null,"abstract":"Abstract. The application of cholesteric liquid crystals and composites containing them for visualization of thermal field and temperature measurement is very well known. Despite all disadvantages as limited precision and adhesion to the studied surface, this method is still of interest. In this work, we present the results of preliminary studies on polymer-dispersed cholesteric liquid crystal (PDCLC) composites designed for visualization and measurement of point temperature changes which can be used in medical diagnostics. Basing on the results of former studies, the perspective PDCLC preparation method as well as high-performance liquid-crystalline chiral nematics were obtained and applied. The microencapsulation in poly(vinyl, alcohol) has been chosen as the method of PDCLC preparation while as liquid-crystalline materials the chiral nematics were adopted.","PeriodicalId":9068,"journal":{"name":"Biuletyn Wojskowej Akademii Technicznej","volume":"66 1","pages":"13-24"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Liquid-crystalline composites for point temperature measurements\",\"authors\":\"Edyta Prusińska-Kurstak, K. Garbat, A. Kołakowska, S. Kłosowicz\",\"doi\":\"10.5604/01.3001.0010.1886\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract. The application of cholesteric liquid crystals and composites containing them for visualization of thermal field and temperature measurement is very well known. Despite all disadvantages as limited precision and adhesion to the studied surface, this method is still of interest. In this work, we present the results of preliminary studies on polymer-dispersed cholesteric liquid crystal (PDCLC) composites designed for visualization and measurement of point temperature changes which can be used in medical diagnostics. Basing on the results of former studies, the perspective PDCLC preparation method as well as high-performance liquid-crystalline chiral nematics were obtained and applied. The microencapsulation in poly(vinyl, alcohol) has been chosen as the method of PDCLC preparation while as liquid-crystalline materials the chiral nematics were adopted.\",\"PeriodicalId\":9068,\"journal\":{\"name\":\"Biuletyn Wojskowej Akademii Technicznej\",\"volume\":\"66 1\",\"pages\":\"13-24\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biuletyn Wojskowej Akademii Technicznej\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5604/01.3001.0010.1886\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biuletyn Wojskowej Akademii Technicznej","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0010.1886","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要胆甾醇型液晶及其复合材料在热场可视化和温度测量中的应用是众所周知的。尽管存在精度和对研究表面的附着力有限等缺点,但这种方法仍然令人感兴趣。在这项工作中,我们介绍了聚合物分散胆甾醇液晶(PDCLC)复合材料的初步研究结果,该复合材料设计用于点温度变化的可视化和测量,可用于医学诊断。在前人研究的基础上,获得了具有前景的PDCLC制备方法以及高性能液晶手性向列相化合物,并进行了应用。选择聚(乙烯、醇)微胶囊作为PDCLC的制备方法,而手性向列相作为液晶材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Liquid-crystalline composites for point temperature measurements
Abstract. The application of cholesteric liquid crystals and composites containing them for visualization of thermal field and temperature measurement is very well known. Despite all disadvantages as limited precision and adhesion to the studied surface, this method is still of interest. In this work, we present the results of preliminary studies on polymer-dispersed cholesteric liquid crystal (PDCLC) composites designed for visualization and measurement of point temperature changes which can be used in medical diagnostics. Basing on the results of former studies, the perspective PDCLC preparation method as well as high-performance liquid-crystalline chiral nematics were obtained and applied. The microencapsulation in poly(vinyl, alcohol) has been chosen as the method of PDCLC preparation while as liquid-crystalline materials the chiral nematics were adopted.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
16 weeks
期刊最新文献
Numerical validation of a method determining thermal diffusivity based on a measurement of a temperature profile Measuring system for comprehensive testing of electrical machines Mathematical models of single-phase long lines Smart home system — modern technology used in single-family housing Analysis of electrical energy consumption on the example of a selected building
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1