腓骨钢板固定及相关短期并发症

IF 1.8 Q2 ORTHOPEDICS Foot and Ankle Specialist Pub Date : 2020-10-01 DOI:10.1177/1938640019873539
H. Bäcker, J. Greisberg, J. T. Vosseller
{"title":"腓骨钢板固定及相关短期并发症","authors":"H. Bäcker, J. Greisberg, J. T. Vosseller","doi":"10.1177/1938640019873539","DOIUrl":null,"url":null,"abstract":"Background. The most common method of surgical stabilization of fibular fractures is plate osteosynthesis. Despite its ubiquity, there is a dearth of large series reporting implant-related outcomes and complications. The purpose of this study was to report on short-term complications and hardware removal after plate fixation of distal fibula fractures. Methods. A retrospective chart analysis and review of radiographic images was performed of 461 ankle fractures between 2011 and 2017. In 404 cases, a fibular fracture was treated surgically; 94.1% underwent tubular and 5.9% locking plate fixation. The primary outcome was radiographic union, with a mean follow-up of 11.6 months. Minor, intermediate, and major complications were recorded as well as the rate of hardware removal. Results. The union-rate with plate fixation was 99.5% (402/404). The overall complication rate was 19.3% (n = 78/404). Of these complications, 79.5% (62/78) were considered minor. These complications included erythema, heterotopic ossification, neurapraxia, delayed union, and deep-vein thrombosis; 20.5% (16/78) of the complications were considered intermediate (9/78, 11.5%) or major (7/78, 9.0%). Intermediate and major complications included deep infection, nonunion/malunion, and osteomyelitis. Subsequent surgery was needed in 7 cases (1.7%, 7/404). In another 93 patients, hardware-related symptoms were identified: 23 (5.7%) underwent syndesmosis screw removal and 54 (13.4%) hardware removal. No correlation to the fixation technique was identified. Conclusion. This study shows a relatively low rate of major complications and a high union rate of 99.5% for fibular plate osteosynthesis in a large cohort. Any other treatment, including other fixation techniques, will need to show an equivalent or better complication and reoperation profile. Level of Evidence: Level III: Retrospective, comparative study","PeriodicalId":39271,"journal":{"name":"Foot and Ankle Specialist","volume":"13 1","pages":"378 - 382"},"PeriodicalIF":1.8000,"publicationDate":"2020-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1938640019873539","citationCount":"6","resultStr":"{\"title\":\"Fibular Plate Fixation and Correlated Short-term Complications\",\"authors\":\"H. Bäcker, J. Greisberg, J. T. Vosseller\",\"doi\":\"10.1177/1938640019873539\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background. The most common method of surgical stabilization of fibular fractures is plate osteosynthesis. Despite its ubiquity, there is a dearth of large series reporting implant-related outcomes and complications. The purpose of this study was to report on short-term complications and hardware removal after plate fixation of distal fibula fractures. Methods. A retrospective chart analysis and review of radiographic images was performed of 461 ankle fractures between 2011 and 2017. In 404 cases, a fibular fracture was treated surgically; 94.1% underwent tubular and 5.9% locking plate fixation. The primary outcome was radiographic union, with a mean follow-up of 11.6 months. Minor, intermediate, and major complications were recorded as well as the rate of hardware removal. Results. The union-rate with plate fixation was 99.5% (402/404). The overall complication rate was 19.3% (n = 78/404). Of these complications, 79.5% (62/78) were considered minor. These complications included erythema, heterotopic ossification, neurapraxia, delayed union, and deep-vein thrombosis; 20.5% (16/78) of the complications were considered intermediate (9/78, 11.5%) or major (7/78, 9.0%). Intermediate and major complications included deep infection, nonunion/malunion, and osteomyelitis. Subsequent surgery was needed in 7 cases (1.7%, 7/404). In another 93 patients, hardware-related symptoms were identified: 23 (5.7%) underwent syndesmosis screw removal and 54 (13.4%) hardware removal. No correlation to the fixation technique was identified. Conclusion. This study shows a relatively low rate of major complications and a high union rate of 99.5% for fibular plate osteosynthesis in a large cohort. Any other treatment, including other fixation techniques, will need to show an equivalent or better complication and reoperation profile. Level of Evidence: Level III: Retrospective, comparative study\",\"PeriodicalId\":39271,\"journal\":{\"name\":\"Foot and Ankle Specialist\",\"volume\":\"13 1\",\"pages\":\"378 - 382\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2020-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1938640019873539\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Foot and Ankle Specialist\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1938640019873539\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot and Ankle Specialist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1938640019873539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 6

摘要

背景腓骨骨折最常见的手术固定方法是钢板内固定。尽管它无处不在,但缺乏大型系列报道植入物相关的结果和并发症。本研究的目的是报告腓骨远端骨折钢板内固定后的短期并发症和硬件移除。方法。2011年至2017年间,对461例踝关节骨折的放射学图像进行了回顾性图表分析和回顾。在404例中,手术治疗腓骨骨折;94.1%采用管状内固定,5.9%采用锁定钢板内固定。主要结果是放射学结合,平均随访11.6个月。记录了轻微、中度和主要并发症以及硬件移除率。后果钢板固定的愈合率为99.5%(402/404)。总并发症发生率为19.3%(n=78/404)。在这些并发症中,79.5%(62/78)被认为是轻微的。这些并发症包括红斑、异位骨化、神经衰弱、延迟愈合和深静脉血栓形成;20.5%(16/78)的并发症被认为是中度(9/78,11.5%)或重度(7/78,9.0%)。中度和重度并发症包括深部感染、骨不连/畸形愈合和骨髓炎。7例(1.7%,7/404)需要进行后续手术。在另外93名患者中,发现了硬件相关症状:23名(5.7%)患者接受了联合韧带螺钉摘除术,54名(13.4%)患者进行了硬件摘除术。未发现与固定技术的相关性。结论这项研究显示,在一个大型队列中,腓骨板接骨术的主要并发症发生率相对较低,愈合率高达99.5%。任何其他治疗,包括其他固定技术,都需要表现出同等或更好的并发症和再次手术情况。证据级别:三级:回顾性比较研究
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fibular Plate Fixation and Correlated Short-term Complications
Background. The most common method of surgical stabilization of fibular fractures is plate osteosynthesis. Despite its ubiquity, there is a dearth of large series reporting implant-related outcomes and complications. The purpose of this study was to report on short-term complications and hardware removal after plate fixation of distal fibula fractures. Methods. A retrospective chart analysis and review of radiographic images was performed of 461 ankle fractures between 2011 and 2017. In 404 cases, a fibular fracture was treated surgically; 94.1% underwent tubular and 5.9% locking plate fixation. The primary outcome was radiographic union, with a mean follow-up of 11.6 months. Minor, intermediate, and major complications were recorded as well as the rate of hardware removal. Results. The union-rate with plate fixation was 99.5% (402/404). The overall complication rate was 19.3% (n = 78/404). Of these complications, 79.5% (62/78) were considered minor. These complications included erythema, heterotopic ossification, neurapraxia, delayed union, and deep-vein thrombosis; 20.5% (16/78) of the complications were considered intermediate (9/78, 11.5%) or major (7/78, 9.0%). Intermediate and major complications included deep infection, nonunion/malunion, and osteomyelitis. Subsequent surgery was needed in 7 cases (1.7%, 7/404). In another 93 patients, hardware-related symptoms were identified: 23 (5.7%) underwent syndesmosis screw removal and 54 (13.4%) hardware removal. No correlation to the fixation technique was identified. Conclusion. This study shows a relatively low rate of major complications and a high union rate of 99.5% for fibular plate osteosynthesis in a large cohort. Any other treatment, including other fixation techniques, will need to show an equivalent or better complication and reoperation profile. Level of Evidence: Level III: Retrospective, comparative study
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Foot and Ankle Specialist
Foot and Ankle Specialist Health Professions-Podiatry
CiteScore
3.10
自引率
0.00%
发文量
100
期刊最新文献
Are SER-II Ankle Fractures Anatomic? Computed Tomography Demonstrates Mortise Malalignment in the Setting of Apparently Normal Radiographs. Sleep Apnea and Postoperative Medical Complications and Health Care Expenditures Following Open Reduction and Internal Fixation of Bimalleolar Ankle Fractures. Utilization of the Modified Lapidus Procedure for Correction of Moderate to Severe Hallux Valgus Deformity With Increased Distal Metatarsal Articular Angle. Modified Bösch Osteotomy Combined With a Percutaneous Adductor Tendon Release for the Treatment of Hallux Valgus Deformity: Learning Curve. Outcomes Following Repeat Ankle Arthroscopy and Microfracture for Osteochondral Lesions of the Talus.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1