消防员自给式呼吸器内部空气质量评价

IF 3 3区 农林科学 Q2 ECOLOGY Fire-Switzerland Pub Date : 2023-09-06 DOI:10.3390/fire6090347
S. Kim, Seunghon Ham
{"title":"消防员自给式呼吸器内部空气质量评价","authors":"S. Kim, Seunghon Ham","doi":"10.3390/fire6090347","DOIUrl":null,"url":null,"abstract":"(1) Background: When a fire breaks out, combustibles are burned and toxic substances such as carbon monoxide (CO), polycyclic aromatic hydrocarbons (PAH), benzene, and hydrogen cyanide are produced. The purpose of this study is to evaluate the air quality inside self-contained breathing apparatus (SCBA) by comparing it to that in the environment where the SCBA charger is installed. (2) Methods: The design of this study was a simulation-based case-control experiment study, and the experiment was conducted at two fire stations located on land and on water. When charging the SCBA, it was differentiated according to the presence or absence of exposure to harmful substances and the degree of exposure. The air quality inside the SCBA in the charging room installed in the fire station garages located on land and in the water, which were not completely isolated from harmful substances, was evaluated. CO, carbon dioxide (CO2), water, and oil mist were measured and analyzed to determine the air quality inside the SCBA. (3) Results: In the case of land firefighting stations, the mean CO among the SCBA internal air quality items was 20 times higher than the outside the SCBA, and higher than the safe range in the group with the highest exposure at the sites of firefighting buildings completely isolated from hazardous substances. The CO levels of all items of water were analyzed to be higher than the safe range in the floating fire station. (4) Conclusions: It was confirmed that the installation environment of an SCBA charging room can affect the safety of the charged internal air quality components. The results of this study can be actively used for the operation and management of SCBA charging room environments when building firefighting buildings in the future for the hygiene, safety, and health of firefighters.","PeriodicalId":36395,"journal":{"name":"Fire-Switzerland","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2023-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Air Quality inside Self-Contained Breathing Apparatus Used by Firefighters\",\"authors\":\"S. Kim, Seunghon Ham\",\"doi\":\"10.3390/fire6090347\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"(1) Background: When a fire breaks out, combustibles are burned and toxic substances such as carbon monoxide (CO), polycyclic aromatic hydrocarbons (PAH), benzene, and hydrogen cyanide are produced. The purpose of this study is to evaluate the air quality inside self-contained breathing apparatus (SCBA) by comparing it to that in the environment where the SCBA charger is installed. (2) Methods: The design of this study was a simulation-based case-control experiment study, and the experiment was conducted at two fire stations located on land and on water. When charging the SCBA, it was differentiated according to the presence or absence of exposure to harmful substances and the degree of exposure. The air quality inside the SCBA in the charging room installed in the fire station garages located on land and in the water, which were not completely isolated from harmful substances, was evaluated. CO, carbon dioxide (CO2), water, and oil mist were measured and analyzed to determine the air quality inside the SCBA. (3) Results: In the case of land firefighting stations, the mean CO among the SCBA internal air quality items was 20 times higher than the outside the SCBA, and higher than the safe range in the group with the highest exposure at the sites of firefighting buildings completely isolated from hazardous substances. The CO levels of all items of water were analyzed to be higher than the safe range in the floating fire station. (4) Conclusions: It was confirmed that the installation environment of an SCBA charging room can affect the safety of the charged internal air quality components. The results of this study can be actively used for the operation and management of SCBA charging room environments when building firefighting buildings in the future for the hygiene, safety, and health of firefighters.\",\"PeriodicalId\":36395,\"journal\":{\"name\":\"Fire-Switzerland\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2023-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire-Switzerland\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.3390/fire6090347\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire-Switzerland","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.3390/fire6090347","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ECOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

(1) 背景:火灾发生时,可燃物被燃烧,产生一氧化碳(CO)、多环芳烃(PAH)、苯和氰化氢等有毒物质。本研究的目的是通过将自给式呼吸器(SCBA)与安装SCBA充电器的环境中的空气质量进行比较,来评估其内部的空气质量。(2) 方法:本研究采用基于模拟的病例对照实验研究,在陆地和水面两个消防站进行实验。当给SCBA充电时,根据是否接触有害物质和接触程度进行区分。对安装在陆地和水中消防站车库中的充电室SCBA内的空气质量进行了评估,这些车库没有完全与有害物质隔离。对CO、二氧化碳(CO2)、水和油雾进行测量和分析,以确定SCBA内的空气质量。(3) 结果:在陆地消防站的情况下,SCBA内部空气质量项目中的平均CO是SCBA外部的20倍,并且高于在与危险物质完全隔离的消防建筑现场暴露量最高的组中的安全范围。经分析,浮式消防站所有水的CO含量均高于安全范围。(4) 结论:SCBA充气室的安装环境会影响充气内部空气质量部件的安全。为了消防员的卫生、安全和健康,本研究结果可积极用于未来建造消防建筑时SCBA充电室环境的操作和管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Air Quality inside Self-Contained Breathing Apparatus Used by Firefighters
(1) Background: When a fire breaks out, combustibles are burned and toxic substances such as carbon monoxide (CO), polycyclic aromatic hydrocarbons (PAH), benzene, and hydrogen cyanide are produced. The purpose of this study is to evaluate the air quality inside self-contained breathing apparatus (SCBA) by comparing it to that in the environment where the SCBA charger is installed. (2) Methods: The design of this study was a simulation-based case-control experiment study, and the experiment was conducted at two fire stations located on land and on water. When charging the SCBA, it was differentiated according to the presence or absence of exposure to harmful substances and the degree of exposure. The air quality inside the SCBA in the charging room installed in the fire station garages located on land and in the water, which were not completely isolated from harmful substances, was evaluated. CO, carbon dioxide (CO2), water, and oil mist were measured and analyzed to determine the air quality inside the SCBA. (3) Results: In the case of land firefighting stations, the mean CO among the SCBA internal air quality items was 20 times higher than the outside the SCBA, and higher than the safe range in the group with the highest exposure at the sites of firefighting buildings completely isolated from hazardous substances. The CO levels of all items of water were analyzed to be higher than the safe range in the floating fire station. (4) Conclusions: It was confirmed that the installation environment of an SCBA charging room can affect the safety of the charged internal air quality components. The results of this study can be actively used for the operation and management of SCBA charging room environments when building firefighting buildings in the future for the hygiene, safety, and health of firefighters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Fire-Switzerland
Fire-Switzerland Multiple-
CiteScore
3.10
自引率
15.60%
发文量
182
审稿时长
11 weeks
期刊最新文献
Fire Risk of Polyethylene (PE)-Based Foam Blocks Used as Interior Building Materials and Fire Suppression through a Simple Surface Coating: Analysis of Vulnerability, Propagation, and Flame Retardancy Experimental Study on Combustion Behavior of U-Shaped Cables with Different Bending Forms and Angles Evaluation of Air Quality inside Self-Contained Breathing Apparatus Used by Firefighters Summer Compound Drought-Heat Extremes Amplify Fire-Weather Risk and Burned Area beyond Historical Thresholds in Chongqing Region, Subtropical China Identification Methodology for Chemical Warehouses Dealing with Flammable Substances Capable of Causing Firewater Pollution
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1