股前外侧游离皮瓣与指动脉吻合重建手部的回顾性分析

IF 1.3 Q3 SURGERY Archives of Plastic Surgery-APS Pub Date : 2024-02-07 eCollection Date: 2024-01-01 DOI:10.1055/a-2161-7419
Jin Soo Kim, Ho Hyung Lee, Sung Hoon Koh, Dong Chul Lee, Si Young Roh, Kyung Jin Lee
{"title":"股前外侧游离皮瓣与指动脉吻合重建手部的回顾性分析","authors":"Jin Soo Kim, Ho Hyung Lee, Sung Hoon Koh, Dong Chul Lee, Si Young Roh, Kyung Jin Lee","doi":"10.1055/a-2161-7419","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to analyze cases of anterolateral thigh (ALT) free flap used for hand reconstruction with terminal perforator-to-digital artery anastomosis. Patients who underwent ALT free flap placement with terminal perforator-to-digital artery anastomosis for hand reconstruction between January 2011 and August 2021 were included. The number, length, and diameter of the perforators and veins, flap size, and operative time were investigated through a retrospective review of charts and photographs. The occurrences of arterial thrombosis, venous thrombosis, arterial spasm, and flap necrosis were analyzed. In total, 50 patients were included in this study. The mean diameter and length of the perforators were 0.68 mm and 3.25 cm, respectively, and the mean number of veins anastomosed was 1.88, with a mean diameter of 0.54 mm. Complications included four cases of arterial thrombosis, one case of venous thrombosis, seven cases of partial necrosis, and one case of total flap failure. Regression analysis showed that a longer perforator was associated with arterial thrombosis whereas larger flap size and number of anastomosed veins were associated with partial necrosis ( <i>p</i>  < 0.05). The terminal perforator-to-digital artery anastomosis offers advantages in using compact free flaps with short pedicle lengths to cover small hand defects.</p>","PeriodicalId":47543,"journal":{"name":"Archives of Plastic Surgery-APS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10901603/pdf/","citationCount":"0","resultStr":"{\"title\":\"Hand Reconstruction Using Anterolateral Thigh Free Flap by Terminal Perforator-to-Digital Artery Anastomosis: Retrospective Analysis.\",\"authors\":\"Jin Soo Kim, Ho Hyung Lee, Sung Hoon Koh, Dong Chul Lee, Si Young Roh, Kyung Jin Lee\",\"doi\":\"10.1055/a-2161-7419\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to analyze cases of anterolateral thigh (ALT) free flap used for hand reconstruction with terminal perforator-to-digital artery anastomosis. Patients who underwent ALT free flap placement with terminal perforator-to-digital artery anastomosis for hand reconstruction between January 2011 and August 2021 were included. The number, length, and diameter of the perforators and veins, flap size, and operative time were investigated through a retrospective review of charts and photographs. The occurrences of arterial thrombosis, venous thrombosis, arterial spasm, and flap necrosis were analyzed. In total, 50 patients were included in this study. The mean diameter and length of the perforators were 0.68 mm and 3.25 cm, respectively, and the mean number of veins anastomosed was 1.88, with a mean diameter of 0.54 mm. Complications included four cases of arterial thrombosis, one case of venous thrombosis, seven cases of partial necrosis, and one case of total flap failure. Regression analysis showed that a longer perforator was associated with arterial thrombosis whereas larger flap size and number of anastomosed veins were associated with partial necrosis ( <i>p</i>  < 0.05). The terminal perforator-to-digital artery anastomosis offers advantages in using compact free flaps with short pedicle lengths to cover small hand defects.</p>\",\"PeriodicalId\":47543,\"journal\":{\"name\":\"Archives of Plastic Surgery-APS\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-02-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10901603/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Plastic Surgery-APS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2161-7419\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Plastic Surgery-APS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2161-7419","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

背景本研究旨在分析应用股前外侧(ALT)游离皮瓣进行指端动脉穿支吻合手部重建的病例。方法纳入2011年1月至2021年8月期间接受无ALT皮瓣置入并吻合指端动脉穿支的手部重建患者。通过对图表和照片的回顾性审查,研究了穿支和静脉的数量、长度和直径、皮瓣大小和手术时间。分析动脉血栓形成、静脉血栓形成、动脉痉挛和皮瓣坏死的发生情况。结果本研究共纳入50例患者。穿支的平均直径和长度分别为0.68 mm和3.25 cm,吻合的平均静脉数为1.88,平均直径为0.54 mm。并发症包括4例动脉血栓形成,1例静脉血栓形成,7例部分坏死,1例全瓣衰竭。回归分析显示,较长的穿支与动脉血栓形成有关,而较大的皮瓣大小和吻合静脉数与部分坏死有关(p<0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Hand Reconstruction Using Anterolateral Thigh Free Flap by Terminal Perforator-to-Digital Artery Anastomosis: Retrospective Analysis.

This study aimed to analyze cases of anterolateral thigh (ALT) free flap used for hand reconstruction with terminal perforator-to-digital artery anastomosis. Patients who underwent ALT free flap placement with terminal perforator-to-digital artery anastomosis for hand reconstruction between January 2011 and August 2021 were included. The number, length, and diameter of the perforators and veins, flap size, and operative time were investigated through a retrospective review of charts and photographs. The occurrences of arterial thrombosis, venous thrombosis, arterial spasm, and flap necrosis were analyzed. In total, 50 patients were included in this study. The mean diameter and length of the perforators were 0.68 mm and 3.25 cm, respectively, and the mean number of veins anastomosed was 1.88, with a mean diameter of 0.54 mm. Complications included four cases of arterial thrombosis, one case of venous thrombosis, seven cases of partial necrosis, and one case of total flap failure. Regression analysis showed that a longer perforator was associated with arterial thrombosis whereas larger flap size and number of anastomosed veins were associated with partial necrosis ( p  < 0.05). The terminal perforator-to-digital artery anastomosis offers advantages in using compact free flaps with short pedicle lengths to cover small hand defects.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.10
自引率
6.70%
发文量
131
审稿时长
10 weeks
期刊最新文献
Minilifting: Short-Scar Rhytidectomy with Thread Lifting. The Old and the New-An Ellege. Distally Based Lymphatic Microsurgical Preventive Healing Approach-A Modification of the Classic Approach. Safety and Effectiveness of Liposuction Modalities in Managing Lipedema: Systematic Review and Meta-analysis. "Funducation"-The New Age of Learning, Intersection of Education, and Fun.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1