使用虚拟牙齿制备工作流程与传统技术进行临时牙冠边缘拟合的体外比较。

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE The Journal of Indian Prosthodontic Society Pub Date : 2023-10-01 DOI:10.4103/jips.jips_273_23
Amrutha Shenoy, Subhabrata Maiti, Deepak Nallaswamy, Varun Keskar
{"title":"使用虚拟牙齿制备工作流程与传统技术进行临时牙冠边缘拟合的体外比较。","authors":"Amrutha Shenoy, Subhabrata Maiti, Deepak Nallaswamy, Varun Keskar","doi":"10.4103/jips.jips_273_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This study investigates the effectiveness of an innovative virtual tooth preparation workflow for the fabrication of dental crowns using cone-beam computed tomography (CBCT) and intraoral scanners (IOSs) with conventional workflow using extraoral/laboratory scanners.</p><p><strong>Settings and design: </strong>This in vitro experimental study was conducted in the laboratory of a university in Chennai, India. The dental laboratory and research facilities at the institution were utilized for the fabrication of the temporary crowns and the data acquisition process.</p><p><strong>Materials and methods: </strong>Institutional approval was obtained from the university. It was basically a comparison between the virtual prep technique using CBCT and IOS and the conventional digital technique using extra oral scanners (EOS) for temporary crown fabrication. The sample size was estimated using an effect size of 1.5004, assuming a normal distribution, a significance level of 0.05, and a power of 0.95 in G power software. Based on this calculation, an extracted second lower molar was used to fabricate 10 samples in each group. The samples were divided into three groups: the CBCT (Group 1), the IOS (Group 2), and laboratory scanner (Group 3 as control) groups. The vertical marginal gap of all the surfaces of the crown was evaluated using a scanning electron microscope.</p><p><strong>Statistical analysis used: </strong>Data were analyzed using one-way ANOVA using the SPSS software version 26.0, IBM, Armonk, NY, USA.</p><p><strong>Results: </strong>Acceptable marginal discrepancy values were obtained in all three groups. There was no significant difference in the marginal discrepancy recorded (P = 0.113).</p><p><strong>Conclusion: </strong>Virtual tooth preparation using CBCT and IOSs can be used as an alternative to the conventional workflow for provisional crown and bridge fabrication.</p>","PeriodicalId":22669,"journal":{"name":"The Journal of Indian Prosthodontic Society","volume":"23 4","pages":"391-397"},"PeriodicalIF":1.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10705005/pdf/","citationCount":"0","resultStr":"{\"title\":\"An <i>in vitro</i> comparison of the marginal fit of provisional crowns using the virtual tooth preparation workflow against the traditional technique.\",\"authors\":\"Amrutha Shenoy, Subhabrata Maiti, Deepak Nallaswamy, Varun Keskar\",\"doi\":\"10.4103/jips.jips_273_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>This study investigates the effectiveness of an innovative virtual tooth preparation workflow for the fabrication of dental crowns using cone-beam computed tomography (CBCT) and intraoral scanners (IOSs) with conventional workflow using extraoral/laboratory scanners.</p><p><strong>Settings and design: </strong>This in vitro experimental study was conducted in the laboratory of a university in Chennai, India. The dental laboratory and research facilities at the institution were utilized for the fabrication of the temporary crowns and the data acquisition process.</p><p><strong>Materials and methods: </strong>Institutional approval was obtained from the university. It was basically a comparison between the virtual prep technique using CBCT and IOS and the conventional digital technique using extra oral scanners (EOS) for temporary crown fabrication. The sample size was estimated using an effect size of 1.5004, assuming a normal distribution, a significance level of 0.05, and a power of 0.95 in G power software. Based on this calculation, an extracted second lower molar was used to fabricate 10 samples in each group. The samples were divided into three groups: the CBCT (Group 1), the IOS (Group 2), and laboratory scanner (Group 3 as control) groups. The vertical marginal gap of all the surfaces of the crown was evaluated using a scanning electron microscope.</p><p><strong>Statistical analysis used: </strong>Data were analyzed using one-way ANOVA using the SPSS software version 26.0, IBM, Armonk, NY, USA.</p><p><strong>Results: </strong>Acceptable marginal discrepancy values were obtained in all three groups. There was no significant difference in the marginal discrepancy recorded (P = 0.113).</p><p><strong>Conclusion: </strong>Virtual tooth preparation using CBCT and IOSs can be used as an alternative to the conventional workflow for provisional crown and bridge fabrication.</p>\",\"PeriodicalId\":22669,\"journal\":{\"name\":\"The Journal of Indian Prosthodontic Society\",\"volume\":\"23 4\",\"pages\":\"391-397\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10705005/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Indian Prosthodontic Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jips.jips_273_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Indian Prosthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jips.jips_273_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究调查了一种创新的虚拟牙齿制备工作流程的有效性,该工作流程用于使用锥形束计算机断层扫描(CBCT)和口内扫描仪(IOS)制造牙冠,并使用口外/实验室扫描仪进行常规工作流程。设置和设计:这项体外实验研究是在印度金奈一所大学的实验室进行的。该机构的牙科实验室和研究设施用于制作临时牙冠和数据采集过程。材料和方法:获得该大学的机构批准。这基本上是使用CBCT和IOS的虚拟准备技术与使用口腔外扫描仪(EOS)制作临时牙冠的传统数字技术之间的比较。假设G power软件中的正态分布、显著性水平为0.05和幂为0.95,使用1.5004的效应大小来估计样本量。基于该计算,使用提取的第二下摩尔在每组中制备10个样品。样本分为三组:CBCT(第1组)、IOS(第2组)和实验室扫描仪(第3组为对照组)。使用扫描电子显微镜评估牙冠所有表面的垂直边缘间隙。使用的统计分析:数据使用SPSS软件版本26.0(IBM,Armonk,NY,USA)进行单因素方差分析。结果:三组均获得可接受的边际差异值。记录的边缘差异没有显著差异(P=0.113)。结论:使用CBCT和IOS的虚拟牙齿制备可以作为临时牙冠和牙桥制造的传统工作流程的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An in vitro comparison of the marginal fit of provisional crowns using the virtual tooth preparation workflow against the traditional technique.

Aim: This study investigates the effectiveness of an innovative virtual tooth preparation workflow for the fabrication of dental crowns using cone-beam computed tomography (CBCT) and intraoral scanners (IOSs) with conventional workflow using extraoral/laboratory scanners.

Settings and design: This in vitro experimental study was conducted in the laboratory of a university in Chennai, India. The dental laboratory and research facilities at the institution were utilized for the fabrication of the temporary crowns and the data acquisition process.

Materials and methods: Institutional approval was obtained from the university. It was basically a comparison between the virtual prep technique using CBCT and IOS and the conventional digital technique using extra oral scanners (EOS) for temporary crown fabrication. The sample size was estimated using an effect size of 1.5004, assuming a normal distribution, a significance level of 0.05, and a power of 0.95 in G power software. Based on this calculation, an extracted second lower molar was used to fabricate 10 samples in each group. The samples were divided into three groups: the CBCT (Group 1), the IOS (Group 2), and laboratory scanner (Group 3 as control) groups. The vertical marginal gap of all the surfaces of the crown was evaluated using a scanning electron microscope.

Statistical analysis used: Data were analyzed using one-way ANOVA using the SPSS software version 26.0, IBM, Armonk, NY, USA.

Results: Acceptable marginal discrepancy values were obtained in all three groups. There was no significant difference in the marginal discrepancy recorded (P = 0.113).

Conclusion: Virtual tooth preparation using CBCT and IOSs can be used as an alternative to the conventional workflow for provisional crown and bridge fabrication.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
The Journal of Indian Prosthodontic Society
The Journal of Indian Prosthodontic Society DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.20
自引率
8.30%
发文量
26
审稿时长
20 weeks
期刊最新文献
A comparative evaluation of marginal fit and microleakage of computer-aided design/computer-aided manufacturing-milled zirconia and prefabricated posterior occlusal veneers: An in vitrostudy. An evaluation of antagonist enamel wear opposing full-coverage zirconia crowns versus other ceramics full-coverage crowns and natural enamel - An umbrella review. Evaluation of flexural strength and microhardness in Vaccinium macrocarpon (cranberry)-added self-cure polymethyl methacrylate dental resin: An in vitro study. Knowledge and awareness about temporomandibular disorder among dentists in India: Questionnaire study and review. Precise jaw relation recorder: An innovative device for prosthodontic rehabilitation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1