颈部颈柱和颈索及颈柱在狭窄性鞭笞中的反应:有限元建模研究。

Narayan Yoganandan, Balaji Harinathan, Aditya Vedantam
{"title":"颈部颈柱和颈索及颈柱在狭窄性鞭笞中的反应:有限元建模研究。","authors":"Narayan Yoganandan, Balaji Harinathan, Aditya Vedantam","doi":"10.1115/1.4063250","DOIUrl":null,"url":null,"abstract":"<p><p>Spine degeneration is a normal aging process. It may lead to stenotic spines that may have implications for pain and quality of life. The diagnosis is based on clinical symptomatology and imaging. Magnetic resonance images often reveal the nature and degree of stenosis of the spine. Stenosis is concerning to clinicians and patients because of the decreased space in the spinal canal and potential for elevated risk of cord and/or osteoligamentous spinal column injuries. Numerous finite element models of the cervical spine have been developed to study the biomechanics of the osteoligamentous column such as range of motion and vertebral stress; however, spinal cord modeling is often ignored. The objective of this study was to determine the external column and internal cord and disc responses of stenotic spines using finite element modeling. A validated model of the subaxial spinal column was used. The osteoligamentous column was modified to include the spinal cord. Mild, moderate, and severe degrees of stenosis commonly identified in civilian populations were simulated at C5-C6. The column-cord model was subjected to postero-anterior acceleration at T1. The range of motion, disc pressure, and cord stress-strain were obtained at the index and superior and inferior adjacent levels of the stenosis. The external metric representing the segmental motion was insensitive while the intrinsic disc and cord variables were more sensitive, and the index level was more affected by stenosis. These findings may influence surgical planning and patient education in personalized medicine.</p>","PeriodicalId":73734,"journal":{"name":"Journal of engineering and science in medical diagnostics and therapy","volume":"7 2","pages":"021003"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10583276/pdf/jesmdt-23-1045_021003.pdf","citationCount":"0","resultStr":"{\"title\":\"Cervical Column and Cord and Column Responses in Whiplash With Stenosis: A Finite Element Modeling Study.\",\"authors\":\"Narayan Yoganandan, Balaji Harinathan, Aditya Vedantam\",\"doi\":\"10.1115/1.4063250\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Spine degeneration is a normal aging process. It may lead to stenotic spines that may have implications for pain and quality of life. The diagnosis is based on clinical symptomatology and imaging. Magnetic resonance images often reveal the nature and degree of stenosis of the spine. Stenosis is concerning to clinicians and patients because of the decreased space in the spinal canal and potential for elevated risk of cord and/or osteoligamentous spinal column injuries. Numerous finite element models of the cervical spine have been developed to study the biomechanics of the osteoligamentous column such as range of motion and vertebral stress; however, spinal cord modeling is often ignored. The objective of this study was to determine the external column and internal cord and disc responses of stenotic spines using finite element modeling. A validated model of the subaxial spinal column was used. The osteoligamentous column was modified to include the spinal cord. Mild, moderate, and severe degrees of stenosis commonly identified in civilian populations were simulated at C5-C6. The column-cord model was subjected to postero-anterior acceleration at T1. The range of motion, disc pressure, and cord stress-strain were obtained at the index and superior and inferior adjacent levels of the stenosis. The external metric representing the segmental motion was insensitive while the intrinsic disc and cord variables were more sensitive, and the index level was more affected by stenosis. These findings may influence surgical planning and patient education in personalized medicine.</p>\",\"PeriodicalId\":73734,\"journal\":{\"name\":\"Journal of engineering and science in medical diagnostics and therapy\",\"volume\":\"7 2\",\"pages\":\"021003\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10583276/pdf/jesmdt-23-1045_021003.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of engineering and science in medical diagnostics and therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4063250\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of engineering and science in medical diagnostics and therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4063250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/3 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

脊椎退化是一个正常的衰老过程。它可能会导致脊椎狭窄,这可能会影响疼痛和生活质量。诊断是基于临床症状和影像学。磁共振图像经常显示脊柱狭窄的性质和程度。狭窄是临床医生和患者关注的问题,因为椎管内的空间减少,脊髓和/或骨韧带性脊柱损伤的风险可能增加。已经开发了许多颈椎的有限元模型来研究骨韧带柱的生物力学,例如运动范围和脊椎应力;然而,脊髓建模往往被忽视。本研究的目的是使用有限元模型确定狭窄脊柱的外柱、内索和椎间盘反应。使用经验证的亚轴脊柱模型。对骨韧带柱进行了改造,使其包括脊髓。在C5-C6中模拟了平民人群中常见的轻度、中度和重度狭窄。柱索模型在T1时受到前后加速度。在狭窄的指数和上下相邻水平处获得运动范围、椎间盘压力和脊髓应力-应变。代表节段运动的外部指标是不敏感的,而固有的椎间盘和脊髓变量更敏感,指数水平更受狭窄的影响。这些发现可能会影响个性化医疗中的手术计划和患者教育。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Cervical Column and Cord and Column Responses in Whiplash With Stenosis: A Finite Element Modeling Study.

Spine degeneration is a normal aging process. It may lead to stenotic spines that may have implications for pain and quality of life. The diagnosis is based on clinical symptomatology and imaging. Magnetic resonance images often reveal the nature and degree of stenosis of the spine. Stenosis is concerning to clinicians and patients because of the decreased space in the spinal canal and potential for elevated risk of cord and/or osteoligamentous spinal column injuries. Numerous finite element models of the cervical spine have been developed to study the biomechanics of the osteoligamentous column such as range of motion and vertebral stress; however, spinal cord modeling is often ignored. The objective of this study was to determine the external column and internal cord and disc responses of stenotic spines using finite element modeling. A validated model of the subaxial spinal column was used. The osteoligamentous column was modified to include the spinal cord. Mild, moderate, and severe degrees of stenosis commonly identified in civilian populations were simulated at C5-C6. The column-cord model was subjected to postero-anterior acceleration at T1. The range of motion, disc pressure, and cord stress-strain were obtained at the index and superior and inferior adjacent levels of the stenosis. The external metric representing the segmental motion was insensitive while the intrinsic disc and cord variables were more sensitive, and the index level was more affected by stenosis. These findings may influence surgical planning and patient education in personalized medicine.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
High-Speed Three-Dimensional-Digital Image Correlation and Schlieren Imaging Integrated With Shock Tube Loading for Investigating Dynamic Response of Human Tympanic Membrane Exposed to Blasts. Quantifying the Fascicular Changes in Recovered Achilles Tendon Patients Using Diffusion Magnetic Resonance Imaging and Tractography. Assistive Technology for Real-Time Fall Prevention during Walking: Evaluation of the Effect of an Intelligent Foot Orthosis A Simple Poc Device for Temperature Control of Multiple Reactions During Recombinase Polymerase Amplification Auxetic Structure Inspired Microneedle Arrays for Minimally Invasive Drug Delivery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1