{"title":"一种新的基于CSoDoA的多DER交流微电网被动孤岛检测技术","authors":"Sivaramarao Bodda,&nbsp;Prashant Agnihotri,&nbsp;Santosh Biswas","doi":"10.1002/adc2.120","DOIUrl":null,"url":null,"abstract":"<p>Micro-grid islanding methods are gaining importance as the presence of renewable energy resources is becoming increasingly popular in power distribution. Among all the islanding methods, passive methods are easy to implement and applicable to all types of DERs provided the NDZ is minimized. This article presents a novel passive islanding detection method based on the CSoDoA of ellipse formed by the successive phase voltages to address the NDZ problem. The peak magnitude and phase angle difference of voltages are the parameters to be estimated to compute the area of the ellipse. State-of-the-art passive methods consider the effect of either magnitude or phase angle or frequency as an islanding detection metric. The CSoDoA metric combines the effect of both magnitude and phase angle thereby reducing the NDZ. The proposed method is validated on both synchronous and inverter-interfaced DERs. The test systems considered are both single-DER based MG and modified IEEE 13 bus multi-DER MG. The CSoDoA algorithm is implemented on a Raspberry-Pi controller and validated using HIL workbench with real-time simulator OP-4510. Various islanding and non-islanding events are simulated, tested and it is evident from the results that it has a very small NDZ.</p>","PeriodicalId":100030,"journal":{"name":"Advanced Control for Applications","volume":"5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel CSoDoA based passive islanding detection technique for multi-DER AC microgrid control\",\"authors\":\"Sivaramarao Bodda,&nbsp;Prashant Agnihotri,&nbsp;Santosh Biswas\",\"doi\":\"10.1002/adc2.120\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Micro-grid islanding methods are gaining importance as the presence of renewable energy resources is becoming increasingly popular in power distribution. Among all the islanding methods, passive methods are easy to implement and applicable to all types of DERs provided the NDZ is minimized. This article presents a novel passive islanding detection method based on the CSoDoA of ellipse formed by the successive phase voltages to address the NDZ problem. The peak magnitude and phase angle difference of voltages are the parameters to be estimated to compute the area of the ellipse. State-of-the-art passive methods consider the effect of either magnitude or phase angle or frequency as an islanding detection metric. The CSoDoA metric combines the effect of both magnitude and phase angle thereby reducing the NDZ. The proposed method is validated on both synchronous and inverter-interfaced DERs. The test systems considered are both single-DER based MG and modified IEEE 13 bus multi-DER MG. The CSoDoA algorithm is implemented on a Raspberry-Pi controller and validated using HIL workbench with real-time simulator OP-4510. Various islanding and non-islanding events are simulated, tested and it is evident from the results that it has a very small NDZ.</p>\",\"PeriodicalId\":100030,\"journal\":{\"name\":\"Advanced Control for Applications\",\"volume\":\"5 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Control for Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/adc2.120\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Control for Applications","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adc2.120","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着可再生能源在配电中越来越受欢迎,微电网孤岛方法越来越重要。在所有孤岛方法中,如果NDZ最小化,被动方法易于实施,适用于所有类型的DER。为了解决NDZ问题,本文提出了一种新的基于连续相电压形成的椭圆的CSoDoA的无源孤岛检测方法。电压的峰值幅度和相位角差是为了计算椭圆的面积而要估计的参数。现有技术的无源方法将幅度或相位角或频率的影响视为孤岛检测度量。CSoDoA度量结合了幅度和相位角的影响,从而降低了NDZ。所提出的方法在同步和逆变器接口的DER上都得到了验证。所考虑的测试系统是基于单DER的MG和修改的IEEE 13总线多DER MG。CSoDoA算法在Raspberry Pi控制器上实现,并使用带有实时模拟器OP-4510的HIL工作台进行验证。模拟和测试了各种孤岛和非孤岛事件,从结果中可以明显看出,它的NDZ非常小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A novel CSoDoA based passive islanding detection technique for multi-DER AC microgrid control

Micro-grid islanding methods are gaining importance as the presence of renewable energy resources is becoming increasingly popular in power distribution. Among all the islanding methods, passive methods are easy to implement and applicable to all types of DERs provided the NDZ is minimized. This article presents a novel passive islanding detection method based on the CSoDoA of ellipse formed by the successive phase voltages to address the NDZ problem. The peak magnitude and phase angle difference of voltages are the parameters to be estimated to compute the area of the ellipse. State-of-the-art passive methods consider the effect of either magnitude or phase angle or frequency as an islanding detection metric. The CSoDoA metric combines the effect of both magnitude and phase angle thereby reducing the NDZ. The proposed method is validated on both synchronous and inverter-interfaced DERs. The test systems considered are both single-DER based MG and modified IEEE 13 bus multi-DER MG. The CSoDoA algorithm is implemented on a Raspberry-Pi controller and validated using HIL workbench with real-time simulator OP-4510. Various islanding and non-islanding events are simulated, tested and it is evident from the results that it has a very small NDZ.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
0
期刊最新文献
Issue Information Efficient parameter estimation for second order plus dead time systems in process plant control Optimal installation of DG in radial distribution network using arithmetic optimization algorithm To cascade feedback loops, or not? A novel modulation for four-switch Buck-boost converter to eliminate the right half plane zero point
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1