Ivan Belousov, Leonid Danyushevsky, Karsten Goemann, Sarah Gilbert, Paul Olin, Jay Thompson, Elena Lounejeva, Dieter Garbe-Schönberg
{"title":"STDGL3,一种通过激光烧蚀ICP-MS分析硫化物矿物的参考材料:基质效应的评估以及激光波长和脉冲宽度的影响","authors":"Ivan Belousov, Leonid Danyushevsky, Karsten Goemann, Sarah Gilbert, Paul Olin, Jay Thompson, Elena Lounejeva, Dieter Garbe-Schönberg","doi":"10.1111/ggr.12512","DOIUrl":null,"url":null,"abstract":"<p>A new reference material, STDGL3, for the calibration of <i>in situ</i> analyses of sulfide minerals by LA-ICP-MS has been developed and characterised. It represents a lithium-borate-based glass containing a mixture of Zn- and Fe-sulfide concentrates doped with several chalcophile elements as well as Zr, Gd, Hf and Ta required for assessing common interferences on Ag, Au and Pt. STDGL3 has a wider range of elements and a better homogeneity compared with existing reference materials for LA-ICP-MS analysis of sulfides. Compositional variations for most elements are below 3% RSD, below 5% RSD for Ag, Au and Pt, and below 7% RSD for Se, when performing spot analyses with a 50 μm beam size. Its preparation recipe is reproducible allowing for multiple batches to be made. Use of STDGL3 significantly improves accuracy of sulfide mineral analysis by LA-ICP-MS when compared with use of other available reference materials. Performance of STDGL3 was evaluated using several different laser systems. No significant change was observed between 193 nm ArF excimer lasers with 5 and 20 ns pulse widths, but use of 213 and 248 nm lasers displays more systematic differences, especially when analysing galena. Correction coefficients are needed for some elements (Zn and Cd in particular) when analysing sulfide minerals using STDGL3 as a calibration reference material.</p>","PeriodicalId":12631,"journal":{"name":"Geostandards and Geoanalytical Research","volume":"47 3","pages":"493-508"},"PeriodicalIF":2.7000,"publicationDate":"2023-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/ggr.12512","citationCount":"3","resultStr":"{\"title\":\"STDGL3, a Reference Material for Analysis of Sulfide Minerals by Laser Ablation ICP-MS: An Assessment of Matrix Effects and the Impact of Laser Wavelengths and Pulse Widths\",\"authors\":\"Ivan Belousov, Leonid Danyushevsky, Karsten Goemann, Sarah Gilbert, Paul Olin, Jay Thompson, Elena Lounejeva, Dieter Garbe-Schönberg\",\"doi\":\"10.1111/ggr.12512\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A new reference material, STDGL3, for the calibration of <i>in situ</i> analyses of sulfide minerals by LA-ICP-MS has been developed and characterised. It represents a lithium-borate-based glass containing a mixture of Zn- and Fe-sulfide concentrates doped with several chalcophile elements as well as Zr, Gd, Hf and Ta required for assessing common interferences on Ag, Au and Pt. STDGL3 has a wider range of elements and a better homogeneity compared with existing reference materials for LA-ICP-MS analysis of sulfides. Compositional variations for most elements are below 3% RSD, below 5% RSD for Ag, Au and Pt, and below 7% RSD for Se, when performing spot analyses with a 50 μm beam size. Its preparation recipe is reproducible allowing for multiple batches to be made. Use of STDGL3 significantly improves accuracy of sulfide mineral analysis by LA-ICP-MS when compared with use of other available reference materials. Performance of STDGL3 was evaluated using several different laser systems. No significant change was observed between 193 nm ArF excimer lasers with 5 and 20 ns pulse widths, but use of 213 and 248 nm lasers displays more systematic differences, especially when analysing galena. Correction coefficients are needed for some elements (Zn and Cd in particular) when analysing sulfide minerals using STDGL3 as a calibration reference material.</p>\",\"PeriodicalId\":12631,\"journal\":{\"name\":\"Geostandards and Geoanalytical Research\",\"volume\":\"47 3\",\"pages\":\"493-508\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/ggr.12512\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Geostandards and Geoanalytical Research\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/ggr.12512\",\"RegionNum\":2,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"GEOCHEMISTRY & GEOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geostandards and Geoanalytical Research","FirstCategoryId":"89","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ggr.12512","RegionNum":2,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GEOCHEMISTRY & GEOPHYSICS","Score":null,"Total":0}
STDGL3, a Reference Material for Analysis of Sulfide Minerals by Laser Ablation ICP-MS: An Assessment of Matrix Effects and the Impact of Laser Wavelengths and Pulse Widths
A new reference material, STDGL3, for the calibration of in situ analyses of sulfide minerals by LA-ICP-MS has been developed and characterised. It represents a lithium-borate-based glass containing a mixture of Zn- and Fe-sulfide concentrates doped with several chalcophile elements as well as Zr, Gd, Hf and Ta required for assessing common interferences on Ag, Au and Pt. STDGL3 has a wider range of elements and a better homogeneity compared with existing reference materials for LA-ICP-MS analysis of sulfides. Compositional variations for most elements are below 3% RSD, below 5% RSD for Ag, Au and Pt, and below 7% RSD for Se, when performing spot analyses with a 50 μm beam size. Its preparation recipe is reproducible allowing for multiple batches to be made. Use of STDGL3 significantly improves accuracy of sulfide mineral analysis by LA-ICP-MS when compared with use of other available reference materials. Performance of STDGL3 was evaluated using several different laser systems. No significant change was observed between 193 nm ArF excimer lasers with 5 and 20 ns pulse widths, but use of 213 and 248 nm lasers displays more systematic differences, especially when analysing galena. Correction coefficients are needed for some elements (Zn and Cd in particular) when analysing sulfide minerals using STDGL3 as a calibration reference material.
期刊介绍:
Geostandards & Geoanalytical Research is an international journal dedicated to advancing the science of reference materials, analytical techniques and data quality relevant to the chemical analysis of geological and environmental samples. Papers are accepted for publication following peer review.