摄影测量和扫描电子显微镜

IF 2.1 3区 地球科学 Q2 GEOGRAPHY, PHYSICAL Photogrammetric Record Pub Date : 2006-08-26 DOI:10.1111/J.1477-9730.1975.TB00805.X
A. Boyde, H. F. Ross
{"title":"摄影测量和扫描电子显微镜","authors":"A. Boyde, H. F. Ross","doi":"10.1111/J.1477-9730.1975.TB00805.X","DOIUrl":null,"url":null,"abstract":"The scanning electron microscope forms images of the surfaces of objects located in a vacuum specimen chamber. A fine beam of electrons scans the surface in synchronism with a cathode ray tube whose spot brightness is modulated by the secondary electron signal emanating from the specimen. The system is capable of giving a large depth of focus and thus allows different projections of the specimen to be photographed by tilting the specimen between successive exposures. From a knowledge of the geometry of the projection (which is central or perspective, but may be justifiably treated as a parallel or orthogonal case for high magnification images), it is therefore possible to proceed to three dimensional analyses from the measurement of parallaxes. Part I of this paper deals with the practical problems resulting from mechanical design limitations of specimen stages and plotting instruments, as well as the nature and sources of image distortions. Part II deals with the practical features of the successful plotting instruments designed especially for the solution of a standardised scanning electron microscope problem in which the magnification of the two members of a stereoscopic pair of images is held constant, the angle of divergence of the peripheral “rays” of the projection from the central “ray” is assumed to be negligible (which is the case for high magnification images) and the tilt angle difference between the two specimen attitudes is constant.","PeriodicalId":56094,"journal":{"name":"Photogrammetric Record","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2006-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/J.1477-9730.1975.TB00805.X","citationCount":"11","resultStr":"{\"title\":\"PHOTOGRAMMETRY AND THE SCANNING ELECTRON MICROSCOPE\",\"authors\":\"A. Boyde, H. F. Ross\",\"doi\":\"10.1111/J.1477-9730.1975.TB00805.X\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The scanning electron microscope forms images of the surfaces of objects located in a vacuum specimen chamber. A fine beam of electrons scans the surface in synchronism with a cathode ray tube whose spot brightness is modulated by the secondary electron signal emanating from the specimen. The system is capable of giving a large depth of focus and thus allows different projections of the specimen to be photographed by tilting the specimen between successive exposures. From a knowledge of the geometry of the projection (which is central or perspective, but may be justifiably treated as a parallel or orthogonal case for high magnification images), it is therefore possible to proceed to three dimensional analyses from the measurement of parallaxes. Part I of this paper deals with the practical problems resulting from mechanical design limitations of specimen stages and plotting instruments, as well as the nature and sources of image distortions. Part II deals with the practical features of the successful plotting instruments designed especially for the solution of a standardised scanning electron microscope problem in which the magnification of the two members of a stereoscopic pair of images is held constant, the angle of divergence of the peripheral “rays” of the projection from the central “ray” is assumed to be negligible (which is the case for high magnification images) and the tilt angle difference between the two specimen attitudes is constant.\",\"PeriodicalId\":56094,\"journal\":{\"name\":\"Photogrammetric Record\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2006-08-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1111/J.1477-9730.1975.TB00805.X\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Photogrammetric Record\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1111/J.1477-9730.1975.TB00805.X\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"GEOGRAPHY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photogrammetric Record","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1111/J.1477-9730.1975.TB00805.X","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GEOGRAPHY, PHYSICAL","Score":null,"Total":0}
引用次数: 11

摘要

扫描电子显微镜形成位于真空标本室的物体表面的图像。一束精细的电子束与阴极射线管同步扫描表面,阴极射线管的光斑亮度由从样品发出的二次电子信号调制。该系统能够提供大的聚焦深度,从而允许通过在连续曝光之间倾斜样品来拍摄样品的不同投影。根据投影几何的知识(投影是中心或透视,但对于高倍图像,可以合理地视为平行或正交的情况),因此可以从视差的测量进行三维分析。本文的第一部分讨论了由于试件台和绘图仪器的机械设计限制而导致的实际问题,以及图像畸变的性质和来源。第二部分讨论了成功的绘图仪器的实际特点,这些仪器是专门为解决一个标准化的扫描电子显微镜问题而设计的,在这个问题中,一个立体图像对的两个成员的放大倍率保持不变。投影的外围“射线”与中心“射线”的发散角被假定为可以忽略不计(这是高放大图像的情况),两个标本姿态之间的倾斜角差是恒定的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
PHOTOGRAMMETRY AND THE SCANNING ELECTRON MICROSCOPE
The scanning electron microscope forms images of the surfaces of objects located in a vacuum specimen chamber. A fine beam of electrons scans the surface in synchronism with a cathode ray tube whose spot brightness is modulated by the secondary electron signal emanating from the specimen. The system is capable of giving a large depth of focus and thus allows different projections of the specimen to be photographed by tilting the specimen between successive exposures. From a knowledge of the geometry of the projection (which is central or perspective, but may be justifiably treated as a parallel or orthogonal case for high magnification images), it is therefore possible to proceed to three dimensional analyses from the measurement of parallaxes. Part I of this paper deals with the practical problems resulting from mechanical design limitations of specimen stages and plotting instruments, as well as the nature and sources of image distortions. Part II deals with the practical features of the successful plotting instruments designed especially for the solution of a standardised scanning electron microscope problem in which the magnification of the two members of a stereoscopic pair of images is held constant, the angle of divergence of the peripheral “rays” of the projection from the central “ray” is assumed to be negligible (which is the case for high magnification images) and the tilt angle difference between the two specimen attitudes is constant.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Photogrammetric Record
Photogrammetric Record 地学-成像科学与照相技术
CiteScore
3.60
自引率
25.00%
发文量
71
审稿时长
>12 weeks
期刊介绍: The Photogrammetric Record is an international journal containing original, independently and rapidly refereed articles that reflect modern advancements in photogrammetry, 3D imaging, computer vision, and other related non-contact fields. All aspects of the measurement workflow are relevant, from sensor characterisation and modelling, data acquisition, processing algorithms and product generation, to novel applications. The journal provides a record of new research which will contribute both to the advancement of photogrammetric knowledge and to the application of techniques in novel ways. It also seeks to stimulate debate though correspondence, and carries reviews of recent literature from the wider geomatics discipline. Relevant topics include, but are not restricted to: - Photogrammetric sensor calibration and characterisation - Laser scanning (lidar) - Image and 3D sensor technology (e.g. range cameras, natural user interface systems) - Photogrammetric aspects of image processing (e.g. radiometric methods, feature extraction, image matching and scene classification) - Mobile mapping and unmanned vehicular systems (UVS; UAVs) - Registration and orientation - Data fusion and integration of 3D and 2D datasets - Point cloud processing - 3D modelling and reconstruction - Algorithms and novel software - Visualisation and virtual reality - Terrain/object modelling and photogrammetric product generation - Geometric sensor models - Databases and structures for imaging and 3D modelling - Standards and best practice for data acquisition and storage - Change detection and monitoring, and sequence analysis
期刊最新文献
Clifford Leslie Ogleby Photogrammetric Computer Vision – Statistics, Geometry, Orientation and Reconstruction. By Wolfgang Förstner and Bernhard P. Wrobel. Springer International Publishing, 2016. ISBN 978‐3‐319‐11549‐8. 816 pages with 59 colour figures. Price: £44·99 hardback; £35·99 eBook. Fundamentals of Satellite Remote sensing: An Environmental Approach. Second edition. By Emilio Chuvieco. CRC Press/Taylor & Francis, Boca Raton, Florida, USA. 2016. ISBN 978‐1‐4987‐2805‐8. 468 pages with 267 colour figures. Price: £63·99 hardback; £44·79 eBook. Book review: Structure from motion in the geosciences Building Earth Observation Cameras. By GEORGE Joseph. CRC Press, Taylor and Francis Group, Boca Raton, Florida, USA, 2015. ISBN 978‐1‐4665‐6647‐7. 240 mm × 100 mm. 350 pages. Price: £ 108·00.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1