基于碳纳米材料和铼簇的安培免疫传感器在序贯注射系统中测定三环抗抑郁药

Q4 Chemistry Analitika i Kontrol Pub Date : 2022-01-01 DOI:10.15826/analitika.2022.26.4.002
E. P. Medyantseva, E. R. Gazizullina, D. Brusnitsyn, A. Dobrynin, K. Brylev, A. Mustafina, J. Elistratova
{"title":"基于碳纳米材料和铼簇的安培免疫传感器在序贯注射系统中测定三环抗抑郁药","authors":"E. P. Medyantseva, E. R. Gazizullina, D. Brusnitsyn, A. Dobrynin, K. Brylev, A. Mustafina, J. Elistratova","doi":"10.15826/analitika.2022.26.4.002","DOIUrl":null,"url":null,"abstract":"A method of sequential injection determination of tricyclic antidepressants (amitriptyline, desipramine, imipramine) using amperometric immunosensors based on screen-printed graphite electrodes modified by carbon nanomaterials (carbon nanotubes, graphene oxide or fullerene) in combination with hexarhenium chalcogenide clusters is proposed. Sequential injection analysis was performed at a sweep rate of 10 mV/s; the flow rate (supporting electrolyte – phosphate buffer solution with pH 7.0) was also varied from 20 to 40 µl/s. Composition of the modifier affects the analytical capability of immunosensors. Screening of various types of modifiers showed that the immunosensor based on graphene oxide and cyanide complexes of rhenium chalcogenide clusters exhibited the highest sensitivity of 23.9±0.9 with a range of working concentrations of 1·10–10–1·10–5 M, and even wider range of detectable concentrations, 1·10–10–1·10–4 M was observed for the immunosensor based on fullerene and cyanide complexes of rhenium chalcogenide clusters. The lowest limit of the determined contents was (4–7)·10–11 M. Relative standard deviation of repeatability (Sr) did not exceed 0.046. The results obtained show that the proposed immunosensors can be used in sequential injection determination of trace amounts of medicinal compounds (antidepressants) in biomedical objects.","PeriodicalId":37743,"journal":{"name":"Analitika i Kontrol","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"AMPEROMETRIC IMMUNOSENSORS BASED ON CARBON NANOMATERIALS AND RHENIUM CLUSTERS FOR THE DETERMINATION OF TRICYCLIC ANTIDEPRESSANTS IN A SEQUENTIAL INJECTION SYSTEM\",\"authors\":\"E. P. Medyantseva, E. R. Gazizullina, D. Brusnitsyn, A. Dobrynin, K. Brylev, A. Mustafina, J. Elistratova\",\"doi\":\"10.15826/analitika.2022.26.4.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method of sequential injection determination of tricyclic antidepressants (amitriptyline, desipramine, imipramine) using amperometric immunosensors based on screen-printed graphite electrodes modified by carbon nanomaterials (carbon nanotubes, graphene oxide or fullerene) in combination with hexarhenium chalcogenide clusters is proposed. Sequential injection analysis was performed at a sweep rate of 10 mV/s; the flow rate (supporting electrolyte – phosphate buffer solution with pH 7.0) was also varied from 20 to 40 µl/s. Composition of the modifier affects the analytical capability of immunosensors. Screening of various types of modifiers showed that the immunosensor based on graphene oxide and cyanide complexes of rhenium chalcogenide clusters exhibited the highest sensitivity of 23.9±0.9 with a range of working concentrations of 1·10–10–1·10–5 M, and even wider range of detectable concentrations, 1·10–10–1·10–4 M was observed for the immunosensor based on fullerene and cyanide complexes of rhenium chalcogenide clusters. The lowest limit of the determined contents was (4–7)·10–11 M. Relative standard deviation of repeatability (Sr) did not exceed 0.046. The results obtained show that the proposed immunosensors can be used in sequential injection determination of trace amounts of medicinal compounds (antidepressants) in biomedical objects.\",\"PeriodicalId\":37743,\"journal\":{\"name\":\"Analitika i Kontrol\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analitika i Kontrol\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15826/analitika.2022.26.4.002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analitika i Kontrol","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15826/analitika.2022.26.4.002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种基于碳纳米材料(碳纳米管、氧化石墨烯或富勒烯)修饰的丝网印刷石墨电极与硫属六烯醚簇结合的电流免疫传感器,用于顺序注射检测三环类抗抑郁药(阿米替林、地西帕明、丙咪嗪)的方法。扫描速率为10 mV/s,进行序贯注射分析;流速(支持pH 7.0的电解质-磷酸盐缓冲溶液)也在20至40µl/s之间变化。修饰剂的组成影响免疫传感器的分析能力。对不同类型改性剂的筛选表明,基于氧化石墨烯和硫代铼氰化物配合物的免疫传感器灵敏度最高,灵敏度为23.9±0.9,工作浓度范围为1·10-10-1·10-5 M,基于富勒烯和硫代铼氰化物配合物的免疫传感器检测浓度范围更广,为1·10-10-1·10-4 M。测定含量的最低限为(4-7)·10-11 m,重复性相对标准偏差(Sr)不超过0.046。结果表明,该免疫传感器可用于生物医学对象中微量药物化合物(抗抑郁药)的序次注射测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
AMPEROMETRIC IMMUNOSENSORS BASED ON CARBON NANOMATERIALS AND RHENIUM CLUSTERS FOR THE DETERMINATION OF TRICYCLIC ANTIDEPRESSANTS IN A SEQUENTIAL INJECTION SYSTEM
A method of sequential injection determination of tricyclic antidepressants (amitriptyline, desipramine, imipramine) using amperometric immunosensors based on screen-printed graphite electrodes modified by carbon nanomaterials (carbon nanotubes, graphene oxide or fullerene) in combination with hexarhenium chalcogenide clusters is proposed. Sequential injection analysis was performed at a sweep rate of 10 mV/s; the flow rate (supporting electrolyte – phosphate buffer solution with pH 7.0) was also varied from 20 to 40 µl/s. Composition of the modifier affects the analytical capability of immunosensors. Screening of various types of modifiers showed that the immunosensor based on graphene oxide and cyanide complexes of rhenium chalcogenide clusters exhibited the highest sensitivity of 23.9±0.9 with a range of working concentrations of 1·10–10–1·10–5 M, and even wider range of detectable concentrations, 1·10–10–1·10–4 M was observed for the immunosensor based on fullerene and cyanide complexes of rhenium chalcogenide clusters. The lowest limit of the determined contents was (4–7)·10–11 M. Relative standard deviation of repeatability (Sr) did not exceed 0.046. The results obtained show that the proposed immunosensors can be used in sequential injection determination of trace amounts of medicinal compounds (antidepressants) in biomedical objects.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analitika i Kontrol
Analitika i Kontrol Chemistry-Analytical Chemistry
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: Analitika i Kontrol is a scientific journal covering theoretical and applied aspects of analytical chemistry and analytical control, published since autumn 1997. Founder and publisher of the journal is the Ural Federal University named after the first President of Russia Boris Yeltsin (UrFU, Ekaterinburg).
期刊最新文献
Electrophoretic determination of carboxylic acids in blood serum with intracapillary concentration Fluorescence of anisotropic primary X-ray radiation Selection of the parameters of a multicapillary column for portable gas analyzers by Kovach indices Differentiation of oil samples by isomeric composition of paraffins using cluster analysis methods Important features of retention indices determination in reversed-phase high performance liquid chromatography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1