M. Pourhossein, O. Heravizadeh, F. Omidi, M. Khadem, S. Shahtaheri
{"title":"基于深度共熔溶剂的超声辅助乳化微萃取法分析尿中微量残留的美曲霉嗪","authors":"M. Pourhossein, O. Heravizadeh, F. Omidi, M. Khadem, S. Shahtaheri","doi":"10.17721/moca.2021.153-161","DOIUrl":null,"url":null,"abstract":"Deep eutectic solvent was used as extraction solvent to develop and optimize a new sample preparation method for the determination of metribuzin in urine samples. In order to determine the optimal values of the effective factors in the deep eutectic solvent-based ultrasound assisted emulsification microextraction method, six effective parameters were selected. The design of experiments was performed using the onevariable- at-a-time method. Totally, 96 experimental runs were performed, and the samples were analyzed using high-performance liquid chromatography with a UV detector. Under the optimum conditions, the calibration curve for metribuzin was linear in the concentration range of 5 to 500 μg L-1 for urine samples. The accuracy and reproducibility of the introduced method were determined using the relative recovery (RR %) and relative standard deviation (RSD %) tests on the fortified urine samples. RR % and RSD % were found to be 96.3 – 101.7 % and 3.2 – 7.6 %, respectively. The limit of quantification and the limit of detection were obtained 5 and 0.8 μg L-1, respectively.","PeriodicalId":18626,"journal":{"name":"Methods and Objects of Chemical Analysis","volume":"1 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Ultrasound-Assisted Emulsified Microextraction Based on Deep Eutectic Solvent for Trace Residue Analysis of Metribuzin in Urine Samples\",\"authors\":\"M. Pourhossein, O. Heravizadeh, F. Omidi, M. Khadem, S. Shahtaheri\",\"doi\":\"10.17721/moca.2021.153-161\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Deep eutectic solvent was used as extraction solvent to develop and optimize a new sample preparation method for the determination of metribuzin in urine samples. In order to determine the optimal values of the effective factors in the deep eutectic solvent-based ultrasound assisted emulsification microextraction method, six effective parameters were selected. The design of experiments was performed using the onevariable- at-a-time method. Totally, 96 experimental runs were performed, and the samples were analyzed using high-performance liquid chromatography with a UV detector. Under the optimum conditions, the calibration curve for metribuzin was linear in the concentration range of 5 to 500 μg L-1 for urine samples. The accuracy and reproducibility of the introduced method were determined using the relative recovery (RR %) and relative standard deviation (RSD %) tests on the fortified urine samples. RR % and RSD % were found to be 96.3 – 101.7 % and 3.2 – 7.6 %, respectively. The limit of quantification and the limit of detection were obtained 5 and 0.8 μg L-1, respectively.\",\"PeriodicalId\":18626,\"journal\":{\"name\":\"Methods and Objects of Chemical Analysis\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Methods and Objects of Chemical Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17721/moca.2021.153-161\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Objects of Chemical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17721/moca.2021.153-161","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Ultrasound-Assisted Emulsified Microextraction Based on Deep Eutectic Solvent for Trace Residue Analysis of Metribuzin in Urine Samples
Deep eutectic solvent was used as extraction solvent to develop and optimize a new sample preparation method for the determination of metribuzin in urine samples. In order to determine the optimal values of the effective factors in the deep eutectic solvent-based ultrasound assisted emulsification microextraction method, six effective parameters were selected. The design of experiments was performed using the onevariable- at-a-time method. Totally, 96 experimental runs were performed, and the samples were analyzed using high-performance liquid chromatography with a UV detector. Under the optimum conditions, the calibration curve for metribuzin was linear in the concentration range of 5 to 500 μg L-1 for urine samples. The accuracy and reproducibility of the introduced method were determined using the relative recovery (RR %) and relative standard deviation (RSD %) tests on the fortified urine samples. RR % and RSD % were found to be 96.3 – 101.7 % and 3.2 – 7.6 %, respectively. The limit of quantification and the limit of detection were obtained 5 and 0.8 μg L-1, respectively.
期刊介绍:
The journal "Methods and objects of chemical analysis" is peer-review journal and publishes original articles of theoretical and experimental analysis on topical issues and bio-analytical chemistry, chemical and pharmaceutical analysis, as well as chemical metrology. Submitted works shall cover the results of completed studies and shall make scientific contributions to the relevant area of expertise. The journal publishes review articles, research articles and articles related to latest developments of analytical instrumentations.