{"title":"包覆线电极电化学测定生物体液中的盐酸达泊西汀","authors":"Amani S. Alturiqi","doi":"10.17265/1934-7375/2016.06.004","DOIUrl":null,"url":null,"abstract":"Coated wire sensor for potentiometric determination of DAP (dapoxetine HCl) in pure form and in biological fluids based on DAP-TPB (dapoxetine-tetraphenyl borate) as the sensing element in the presence of DOP (dioctylphthalate) as the plasticizing solvent mediator was prepared. The best performance was obtained with a membrane composition of 10.0% (w/w) ion-pair, 45.0% DOP (w/w) and 45.0% PVC (w/w). The electrode showed a Nernstian response (with a slope of 58.70 mV decade) for the concentration range of 4.2 × 10-1.0 × 10 mol/L. It illustrates a relatively fast response time in the whole concentration range (~15 s) in a pH range of 3.0-7.5 . The selectivity coefficients were determined in relation to several inorganic and organic species. DAP is determined successfully in pure solutions and in biological fluids using the standard additions and potentiometric titrations methods.","PeriodicalId":67212,"journal":{"name":"化学与化工:英文版","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2016-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Electrochemical Determination of Dapoxetine HCl in Biological Fluids Using Coated Wire Electrod\",\"authors\":\"Amani S. Alturiqi\",\"doi\":\"10.17265/1934-7375/2016.06.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Coated wire sensor for potentiometric determination of DAP (dapoxetine HCl) in pure form and in biological fluids based on DAP-TPB (dapoxetine-tetraphenyl borate) as the sensing element in the presence of DOP (dioctylphthalate) as the plasticizing solvent mediator was prepared. The best performance was obtained with a membrane composition of 10.0% (w/w) ion-pair, 45.0% DOP (w/w) and 45.0% PVC (w/w). The electrode showed a Nernstian response (with a slope of 58.70 mV decade) for the concentration range of 4.2 × 10-1.0 × 10 mol/L. It illustrates a relatively fast response time in the whole concentration range (~15 s) in a pH range of 3.0-7.5 . The selectivity coefficients were determined in relation to several inorganic and organic species. DAP is determined successfully in pure solutions and in biological fluids using the standard additions and potentiometric titrations methods.\",\"PeriodicalId\":67212,\"journal\":{\"name\":\"化学与化工:英文版\",\"volume\":\"10 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"化学与化工:英文版\",\"FirstCategoryId\":\"1089\",\"ListUrlMain\":\"https://doi.org/10.17265/1934-7375/2016.06.004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"化学与化工:英文版","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.17265/1934-7375/2016.06.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

以达泊西汀-硼酸四苯酯(DAP- tpb)为传感元件,以邻苯二甲酸二辛酯(DOP)为增塑溶剂介质,制备了用于测定纯生物液和生物液中DAP (dapoxetine HCl)电位的包覆线传感器。当膜组成为10.0% (w/w)离子对、45.0% DOP (w/w)和45.0% PVC (w/w)时,膜性能最佳。在4.2 × 10 ~ 1.0 × 10 mol/L的浓度范围内,电极表现出58.70 mV十阶的能氏响应。在pH为3.0-7.5的整个浓度范围内,反应时间相对较快(~15 s)。测定了对几种无机和有机物质的选择性系数。在纯溶液和生物流体中使用标准添加和电位滴定法成功地测定了DAP。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Electrochemical Determination of Dapoxetine HCl in Biological Fluids Using Coated Wire Electrod
Coated wire sensor for potentiometric determination of DAP (dapoxetine HCl) in pure form and in biological fluids based on DAP-TPB (dapoxetine-tetraphenyl borate) as the sensing element in the presence of DOP (dioctylphthalate) as the plasticizing solvent mediator was prepared. The best performance was obtained with a membrane composition of 10.0% (w/w) ion-pair, 45.0% DOP (w/w) and 45.0% PVC (w/w). The electrode showed a Nernstian response (with a slope of 58.70 mV decade) for the concentration range of 4.2 × 10-1.0 × 10 mol/L. It illustrates a relatively fast response time in the whole concentration range (~15 s) in a pH range of 3.0-7.5 . The selectivity coefficients were determined in relation to several inorganic and organic species. DAP is determined successfully in pure solutions and in biological fluids using the standard additions and potentiometric titrations methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
934
期刊最新文献
Clinical Implications of Cross-Reactive Shellfish Allergens Relationship of Reproductive Hormones and Fertility in Patients with Beta-Thalassemia Major Multi-isotope Analysis of Tartaric Acid Derivative: Potassium Bitartrate Provenance, Guideline Values and Trace and Minor Elements in Bottom Sediments of Tebicuary River and Tapiracuai Stream from Eastern Paraguay by X-Ray Fluorescence Oligosaccharides and Glycan Separation via Capillary Electrophoresis Coupled with Mass Spectroscopy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1