流线LENSAR激光系统对散光的处理

M. Packer
{"title":"流线LENSAR激光系统对散光的处理","authors":"M. Packer","doi":"10.17925/USOR.2017.10.02.99","DOIUrl":null,"url":null,"abstract":"M anagement of astigmatism at the time of cataract or refractive lens surgery has evolved to include arcuate keratotomy and toric intraocular lens (IOL) implantation. Integration of preoperative corneal diagnostic instrumentation via Streamline digital wireless connectivity to the LENSARTM femtosecond laser (LENSAR Inc., Orlando, FL, US) now allows improved precision and accuracy of arcuate incision and toric IOL alignment, eliminating a significant source of error in astigmatism correction. Use of a pre-programmed, surgeondefined nomogram for arcuate incision construction, based on transmitted data from preoperative corneal analysis, permits further efficiency and reduction of transcription error. Toric IOL alignment is currently facilitated with IntelliAxisTM (LENSAR Inc., Orlando, FL, US) corneal marks. Management of astigmatism at the time of cataract surgery provides the refractive benefit of reduced dependence on glasses and sets the stage for correction of presbyopia","PeriodicalId":90077,"journal":{"name":"US ophthalmic review","volume":"10 1","pages":"99"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Management of Astigmatism with the LENSAR Laser System with Streamline\",\"authors\":\"M. Packer\",\"doi\":\"10.17925/USOR.2017.10.02.99\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"M anagement of astigmatism at the time of cataract or refractive lens surgery has evolved to include arcuate keratotomy and toric intraocular lens (IOL) implantation. Integration of preoperative corneal diagnostic instrumentation via Streamline digital wireless connectivity to the LENSARTM femtosecond laser (LENSAR Inc., Orlando, FL, US) now allows improved precision and accuracy of arcuate incision and toric IOL alignment, eliminating a significant source of error in astigmatism correction. Use of a pre-programmed, surgeondefined nomogram for arcuate incision construction, based on transmitted data from preoperative corneal analysis, permits further efficiency and reduction of transcription error. Toric IOL alignment is currently facilitated with IntelliAxisTM (LENSAR Inc., Orlando, FL, US) corneal marks. Management of astigmatism at the time of cataract surgery provides the refractive benefit of reduced dependence on glasses and sets the stage for correction of presbyopia\",\"PeriodicalId\":90077,\"journal\":{\"name\":\"US ophthalmic review\",\"volume\":\"10 1\",\"pages\":\"99\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"US ophthalmic review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17925/USOR.2017.10.02.99\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"US ophthalmic review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17925/USOR.2017.10.02.99","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

白内障或屈光晶体手术时散光的管理已经发展到包括弓形角膜切开术和环形人工晶状体植入术。通过流线数字无线连接将术前角膜诊断仪器集成到LENSARTM飞秒激光器(LENSAR Inc., Orlando, FL, US),现在可以提高弓形切口和环形IOL对准的精度和准确性,消除了散光校正的重要误差来源。基于术前角膜分析传输的数据,使用预先编程的外科医生定义的图进行弓形切口构建,可以进一步提高效率并减少转录错误。目前使用IntelliAxisTM (LENSAR Inc., Orlando, FL, US)角膜标记进行环面人工晶状体对准。在白内障手术中对散光的处理可以减少对眼镜的依赖,为矫正老花眼奠定基础
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Management of Astigmatism with the LENSAR Laser System with Streamline
M anagement of astigmatism at the time of cataract or refractive lens surgery has evolved to include arcuate keratotomy and toric intraocular lens (IOL) implantation. Integration of preoperative corneal diagnostic instrumentation via Streamline digital wireless connectivity to the LENSARTM femtosecond laser (LENSAR Inc., Orlando, FL, US) now allows improved precision and accuracy of arcuate incision and toric IOL alignment, eliminating a significant source of error in astigmatism correction. Use of a pre-programmed, surgeondefined nomogram for arcuate incision construction, based on transmitted data from preoperative corneal analysis, permits further efficiency and reduction of transcription error. Toric IOL alignment is currently facilitated with IntelliAxisTM (LENSAR Inc., Orlando, FL, US) corneal marks. Management of astigmatism at the time of cataract surgery provides the refractive benefit of reduced dependence on glasses and sets the stage for correction of presbyopia
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
New and Emerging Trabecular Meshwork Bypass Stents Current and Emerging Therapies for Leber Hereditary Optic Neuropathy Safety and Efficacy of Suprachorodial Injection of Triamcinolone Acetonide: Review of a Novel Treatment Neurotrophic Keratitis: Exploring the Therapeutic Landscape iDose TR Sustained-release Travoprost Implant for the Treatment of Glaucoma
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1