D. A. Waterman, S. Walker, Bingjie Xu, R. Narbaitz
{"title":"超滤膜在地表水处理中性能评价的实验研究","authors":"D. A. Waterman, S. Walker, Bingjie Xu, R. Narbaitz","doi":"10.2166/WQRJC.2016.039","DOIUrl":null,"url":null,"abstract":"Currently, there is no standard bench-scale dead-end ultrafiltration (UF) testing system. The aim of the present study was to design and build a bench-scale hollow fiber UF system to assess the impact of operational parameters on membrane performance and fouling. A bench-scale hollow fiber UF system was built to operate at a constant flux (±2% of the set-point flux) and included automated backwash cycles. The development of the bench-scale system showed that it is very difficult to maintain a constant flux during the first minute of the filtration cycles, that digital flow meters are problematic, and that the volume of the backwash waste lines should be minimized. The system was evaluated with Ottawa River water, which has a relatively high hydrophobic natural organic matter content and is typical of Northern Canadian waters. The testing using different permeate fluxes, filtration cycle duration and backwash cycle duration showed that this system mimics the performance of larger systems and may be used to assess the impact of operating conditions on membrane fouling and alternative pretreatment options. Modeling the first, middle, and last filtration cycles of the six runs using single and dual blocking mechanisms yielded inconsistent results regarding the controlling fouling mechanisms.","PeriodicalId":54407,"journal":{"name":"Water Quality Research Journal of Canada","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2016-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2166/WQRJC.2016.039","citationCount":"8","resultStr":"{\"title\":\"Bench-scale study of ultrafiltration membranes for evaluating membrane performance in surface water treatment\",\"authors\":\"D. A. Waterman, S. Walker, Bingjie Xu, R. Narbaitz\",\"doi\":\"10.2166/WQRJC.2016.039\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Currently, there is no standard bench-scale dead-end ultrafiltration (UF) testing system. The aim of the present study was to design and build a bench-scale hollow fiber UF system to assess the impact of operational parameters on membrane performance and fouling. A bench-scale hollow fiber UF system was built to operate at a constant flux (±2% of the set-point flux) and included automated backwash cycles. The development of the bench-scale system showed that it is very difficult to maintain a constant flux during the first minute of the filtration cycles, that digital flow meters are problematic, and that the volume of the backwash waste lines should be minimized. The system was evaluated with Ottawa River water, which has a relatively high hydrophobic natural organic matter content and is typical of Northern Canadian waters. The testing using different permeate fluxes, filtration cycle duration and backwash cycle duration showed that this system mimics the performance of larger systems and may be used to assess the impact of operating conditions on membrane fouling and alternative pretreatment options. Modeling the first, middle, and last filtration cycles of the six runs using single and dual blocking mechanisms yielded inconsistent results regarding the controlling fouling mechanisms.\",\"PeriodicalId\":54407,\"journal\":{\"name\":\"Water Quality Research Journal of Canada\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2016-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2166/WQRJC.2016.039\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Water Quality Research Journal of Canada\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2166/WQRJC.2016.039\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Quality Research Journal of Canada","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/WQRJC.2016.039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Environmental Science","Score":null,"Total":0}
Bench-scale study of ultrafiltration membranes for evaluating membrane performance in surface water treatment
Currently, there is no standard bench-scale dead-end ultrafiltration (UF) testing system. The aim of the present study was to design and build a bench-scale hollow fiber UF system to assess the impact of operational parameters on membrane performance and fouling. A bench-scale hollow fiber UF system was built to operate at a constant flux (±2% of the set-point flux) and included automated backwash cycles. The development of the bench-scale system showed that it is very difficult to maintain a constant flux during the first minute of the filtration cycles, that digital flow meters are problematic, and that the volume of the backwash waste lines should be minimized. The system was evaluated with Ottawa River water, which has a relatively high hydrophobic natural organic matter content and is typical of Northern Canadian waters. The testing using different permeate fluxes, filtration cycle duration and backwash cycle duration showed that this system mimics the performance of larger systems and may be used to assess the impact of operating conditions on membrane fouling and alternative pretreatment options. Modeling the first, middle, and last filtration cycles of the six runs using single and dual blocking mechanisms yielded inconsistent results regarding the controlling fouling mechanisms.
期刊介绍:
The Water Quality Research Journal publishes peer-reviewed, scholarly articles on the following general subject areas:
Impact of current and emerging contaminants on aquatic ecosystems
Aquatic ecology (ecohydrology and ecohydraulics, invasive species, biodiversity, and aquatic species at risk)
Conservation and protection of aquatic environments
Responsible resource development and water quality (mining, forestry, hydropower, oil and gas)
Drinking water, wastewater and stormwater treatment technologies and strategies
Impacts and solutions of diffuse pollution (urban and agricultural run-off) on water quality
Industrial water quality
Used water: Reuse and resource recovery
Groundwater quality (management, remediation, fracking, legacy contaminants)
Assessment of surface and subsurface water quality
Regulations, economics, strategies and policies related to water quality
Social science issues in relation to water quality
Water quality in remote areas
Water quality in cold climates
The Water Quality Research Journal is a quarterly publication. It is a forum for original research dealing with the aquatic environment, and should report new and significant findings that advance the understanding of the field. Critical review articles are especially encouraged.