生物医学用多光谱相机在焊接双色温度测量中的应用

K. Nomura, H. Okuda, T. Sano
{"title":"生物医学用多光谱相机在焊接双色温度测量中的应用","authors":"K. Nomura, H. Okuda, T. Sano","doi":"10.2207/qjjws.39.241","DOIUrl":null,"url":null,"abstract":"This study tested a two-color temperature measurement method using a multi-spectral camera designed for biomedical use. We selected the images of 735 nm and 930 nm as wavelengths. Two calibrations were performed before using them for temperature conversion. One was sensitivity calibration between wavelengths, which was conducted by heating the steel surface coated with blackbody spray from the opposite surface and comparing it with the temperature measured by thermography. Another calibration was a pixel shift that took into account the array of elements. This is a correction peculiar to a multi-spectral camera, and it was possible to eliminate a steep temperature error at the end of the temperature discontinuity. In this report, the electrode temperature of the gas tungsten arc was reported as an application example.","PeriodicalId":39980,"journal":{"name":"Yosetsu Gakkai Ronbunshu/Quarterly Journal of the Japan Welding Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of multi-spectral camera for biomedical use to two-color temperature measurement in welding phenomena\",\"authors\":\"K. Nomura, H. Okuda, T. Sano\",\"doi\":\"10.2207/qjjws.39.241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study tested a two-color temperature measurement method using a multi-spectral camera designed for biomedical use. We selected the images of 735 nm and 930 nm as wavelengths. Two calibrations were performed before using them for temperature conversion. One was sensitivity calibration between wavelengths, which was conducted by heating the steel surface coated with blackbody spray from the opposite surface and comparing it with the temperature measured by thermography. Another calibration was a pixel shift that took into account the array of elements. This is a correction peculiar to a multi-spectral camera, and it was possible to eliminate a steep temperature error at the end of the temperature discontinuity. In this report, the electrode temperature of the gas tungsten arc was reported as an application example.\",\"PeriodicalId\":39980,\"journal\":{\"name\":\"Yosetsu Gakkai Ronbunshu/Quarterly Journal of the Japan Welding Society\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Yosetsu Gakkai Ronbunshu/Quarterly Journal of the Japan Welding Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2207/qjjws.39.241\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Materials Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Yosetsu Gakkai Ronbunshu/Quarterly Journal of the Japan Welding Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2207/qjjws.39.241","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Materials Science","Score":null,"Total":0}
引用次数: 0

摘要

本研究利用生物医学用多光谱相机测试了一种双色温度测量方法。我们选择735 nm和930 nm的图像作为波长。在使用它们进行温度转换之前进行了两次校准。一种是波长间的灵敏度校准,通过从对面表面加热涂有黑体喷雾的钢表面,并将其与热像仪测得的温度进行比较。另一种校准是考虑到元素数组的像素位移。这是多光谱相机特有的一种校正,可以消除温度不连续结束时的陡峭温度误差。本文报道了钨气电弧的电极温度作为应用实例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Application of multi-spectral camera for biomedical use to two-color temperature measurement in welding phenomena
This study tested a two-color temperature measurement method using a multi-spectral camera designed for biomedical use. We selected the images of 735 nm and 930 nm as wavelengths. Two calibrations were performed before using them for temperature conversion. One was sensitivity calibration between wavelengths, which was conducted by heating the steel surface coated with blackbody spray from the opposite surface and comparing it with the temperature measured by thermography. Another calibration was a pixel shift that took into account the array of elements. This is a correction peculiar to a multi-spectral camera, and it was possible to eliminate a steep temperature error at the end of the temperature discontinuity. In this report, the electrode temperature of the gas tungsten arc was reported as an application example.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
11
期刊最新文献
Short time Resistance Spot Welding of 1.2GPa Ultra-High Strength Steel using High Frequency Power Supply Strengthening of Al/Cu dissimilar joint due to complicated interface produced by pulsed TIG welding with a constricted nozzle Direct bonding of Ni nanoparticles to a semiconductor Al electrode in air and its form Microstructure of the interface between Aluminum Alloy and Galvannealed Steel Plates Jointed by FSSW Multi-Step Loading Process Evaluation of Solidification Cracking Susceptibility Factors in Carbon Steel and Availability of Ti Addition Based on Theoretical Analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1