使用引流装置的改良套管针技术的计算机层析引导引流。

Koji Togawa, Seishi Nakatsuka, Jitsuro Tsukada, Nobutake Ito, Yosuke Yamamoto, Togo Kogo, Hiroki Yoshikawa, Manabu Misu, Masashi Tamura, Shigeyoshi Soga, Masanori Inoue, Hideki Yashiro, Tadayoshi Kurata, Masahiro Okada, Masahiro Jinzaki
{"title":"使用引流装置的改良套管针技术的计算机层析引导引流。","authors":"Koji Togawa, Seishi Nakatsuka, Jitsuro Tsukada, Nobutake Ito, Yosuke Yamamoto, Togo Kogo, Hiroki Yoshikawa, Manabu Misu, Masashi Tamura, Shigeyoshi Soga, Masanori Inoue, Hideki Yashiro, Tadayoshi Kurata, Masahiro Okada, Masahiro Jinzaki","doi":"10.22575/interventionalradiology.2022-0027","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit <i>Drainaway</i> (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of <i>Drainaway</i> for abscess drainage.</p><p><strong>Material and methods: </strong>In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using <i>Drainaway</i> between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with <i>Drainaway</i> alone), secondary clinical success (avoidance of surgery), and complications were evaluated.</p><p><strong>Results: </strong>The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage.</p><p><strong>Conclusions: </strong><i>Drainaway</i> is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy.</p>","PeriodicalId":73503,"journal":{"name":"Interventional radiology (Higashimatsuyama-shi (Japan)","volume":"1 1","pages":"130-135"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10681752/pdf/","citationCount":"0","resultStr":"{\"title\":\"Computed Tomography-guided Drainage with Modified Trocar Technique Using a <i>Drainaway</i> Drainage Kit.\",\"authors\":\"Koji Togawa, Seishi Nakatsuka, Jitsuro Tsukada, Nobutake Ito, Yosuke Yamamoto, Togo Kogo, Hiroki Yoshikawa, Manabu Misu, Masashi Tamura, Shigeyoshi Soga, Masanori Inoue, Hideki Yashiro, Tadayoshi Kurata, Masahiro Okada, Masahiro Jinzaki\",\"doi\":\"10.22575/interventionalradiology.2022-0027\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit <i>Drainaway</i> (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of <i>Drainaway</i> for abscess drainage.</p><p><strong>Material and methods: </strong>In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using <i>Drainaway</i> between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with <i>Drainaway</i> alone), secondary clinical success (avoidance of surgery), and complications were evaluated.</p><p><strong>Results: </strong>The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage.</p><p><strong>Conclusions: </strong><i>Drainaway</i> is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy.</p>\",\"PeriodicalId\":73503,\"journal\":{\"name\":\"Interventional radiology (Higashimatsuyama-shi (Japan)\",\"volume\":\"1 1\",\"pages\":\"130-135\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10681752/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional radiology (Higashimatsuyama-shi (Japan)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22575/interventionalradiology.2022-0027\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional radiology (Higashimatsuyama-shi (Japan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22575/interventionalradiology.2022-0027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:图像引导下经皮脓肿引流术是一种安全有效的治疗方法。基于改良套管针方法开发的计算机断层引导下的经皮引流试剂盒Drainaway (SB Kawasumi Co., Ltd.)使得仅在计算机断层引导下无需x线透视即可完成该手术成为可能。本研究探讨了引流管用于脓肿引流的可行性和安全性。材料和方法:在这项回顾性观察性研究中,27例患者(男性18例,女性9例;分析7家附属医院于2021年3月至12月间采用计算机断层引导引流术的患者(年龄67.0±12.3岁)。患者有症状,计算机断层扫描穿刺和难治性脓肿。评估技术成功(单独使用计算机断层扫描引流成功)、主要临床成功(单独使用引流成功)、次要临床成功(避免手术)和并发症。结果:脓肿部位分别为腹腔内19例、腹膜后5例、胸腔2例,皮下1例。脓肿平均大小为7.1±3.4 cm。技术成功率为96.4%;1例穿刺路径韧带未穿入。首次临床成功率为77.8%,而导管扩大或更换的二次临床成功率为96.3%。并发症包括一例需要引流的胆道胸膜炎。结论:引流管是一种有效的脓肿引流装置,仅在计算机断层引导下,无需x线透视。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit.

Purpose: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of Drainaway for abscess drainage.

Material and methods: In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using Drainaway between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with Drainaway alone), secondary clinical success (avoidance of surgery), and complications were evaluated.

Results: The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage.

Conclusions: Drainaway is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Preface to the Featured Topic "Image-guided Puncture". Basic Techniques and Technical Tips for Ultrasound-guided Needle Puncture. Embolotherapy of Head and Neck Lesions: Basics and Clinical Tips. Innovative Techniques for Image-guided Percutaneous Puncture: Navigating Complex Cases for Successful Outcomes. Adrenal Hemorrhage as a Complication of Plug-assisted Retrograde Transvenous Obliteration of Gastrorenal Shunt Managed by Adrenal Artery Embolization: A Case Report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1