德涅斯特河中部科马里夫附近晚罗马时代遗址的土壤和考古物品的磁勘探和岩石磁研究

IF 0.6 Q4 GEOCHEMISTRY & GEOPHYSICS Geofizicheskiy Zhurnal-Geophysical Journal Pub Date : 2022-06-02 DOI:10.24028/gj.v44i2.256264
K. Bondar, O. Petrauskas, R. Khomenko, S. Popov
{"title":"德涅斯特河中部科马里夫附近晚罗马时代遗址的土壤和考古物品的磁勘探和岩石磁研究","authors":"K. Bondar, O. Petrauskas, R. Khomenko, S. Popov","doi":"10.24028/gj.v44i2.256264","DOIUrl":null,"url":null,"abstract":"\nThe paper presents the outcome of the magnetic survey at the settlement and cemetery of the production center of the 3rd—5th centuries, Komariv (Khotyn district, Chernivtsi region), which is located on the right bank of the Dniester. The settlement has about seventy anomalies that may have an archaeological origin. The archaeological study of individual anomalies has confirmed, as expected, the reliability of geophysical interpretation of thermal structures (kilns, furnaces) and living and production dugouts deepened into the loess parent rock.\nMagnetic imaging at the cemetery showed about eight tens of local anomalies with an intensity of 1.5—4.5 nT. Excavations of some anomalies revealed the Early Iron Age dugout and two Late Roman graves. However, the other two excavated graves did not cause disturbance of magnetic field.\nLaboratory measurements of magnetic susceptibility, natural remanent magnetization and other concentration-dependent and grain-size-dependent parameters of the ferromagnetic phase, as well as magnetic mineralogy examination have shown that grave pits, which appeared on a magnetic map, are refilled almost exclusively with humus soil material. Magnetic modeling proved graves can create measured anomalies if their magnetization is equal to the magnetization of the humus horizon of the soil. Thus, these grave pits were left open and gradually refilled with moist soil material. In particular, conditions have been created for the formation of detrital remanence.\nWhen restoring the spatial structure of Komariv sites based on magnetic prospecting results, it is necessary to take into account probable multilayered structure of monuments, geomorphological features of the area, which can be misinterpreted as archeological objects, and the fact that important examples of ancient architecture constructed of non-magnetic materials and grave pits refilled immediately after digging will be absent on magnetic maps.\n","PeriodicalId":54141,"journal":{"name":"Geofizicheskiy Zhurnal-Geophysical Journal","volume":"1 1","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2022-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Magnetic prospecting and rock magnetic study of soils and archaeological objects on the Late Roman time sites near Komariv in Middle Transnistria\",\"authors\":\"K. Bondar, O. Petrauskas, R. Khomenko, S. Popov\",\"doi\":\"10.24028/gj.v44i2.256264\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\nThe paper presents the outcome of the magnetic survey at the settlement and cemetery of the production center of the 3rd—5th centuries, Komariv (Khotyn district, Chernivtsi region), which is located on the right bank of the Dniester. The settlement has about seventy anomalies that may have an archaeological origin. The archaeological study of individual anomalies has confirmed, as expected, the reliability of geophysical interpretation of thermal structures (kilns, furnaces) and living and production dugouts deepened into the loess parent rock.\\nMagnetic imaging at the cemetery showed about eight tens of local anomalies with an intensity of 1.5—4.5 nT. Excavations of some anomalies revealed the Early Iron Age dugout and two Late Roman graves. However, the other two excavated graves did not cause disturbance of magnetic field.\\nLaboratory measurements of magnetic susceptibility, natural remanent magnetization and other concentration-dependent and grain-size-dependent parameters of the ferromagnetic phase, as well as magnetic mineralogy examination have shown that grave pits, which appeared on a magnetic map, are refilled almost exclusively with humus soil material. Magnetic modeling proved graves can create measured anomalies if their magnetization is equal to the magnetization of the humus horizon of the soil. Thus, these grave pits were left open and gradually refilled with moist soil material. In particular, conditions have been created for the formation of detrital remanence.\\nWhen restoring the spatial structure of Komariv sites based on magnetic prospecting results, it is necessary to take into account probable multilayered structure of monuments, geomorphological features of the area, which can be misinterpreted as archeological objects, and the fact that important examples of ancient architecture constructed of non-magnetic materials and grave pits refilled immediately after digging will be absent on magnetic maps.\\n\",\"PeriodicalId\":54141,\"journal\":{\"name\":\"Geofizicheskiy Zhurnal-Geophysical Journal\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2022-06-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Geofizicheskiy Zhurnal-Geophysical Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24028/gj.v44i2.256264\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"GEOCHEMISTRY & GEOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geofizicheskiy Zhurnal-Geophysical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24028/gj.v44i2.256264","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"GEOCHEMISTRY & GEOPHYSICS","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了位于德涅斯特河右岸的3 - 5世纪生产中心Komariv (Khotyn区,Chernivtsi地区)的定居点和墓地的磁测量结果。该定居点有大约70个可能有考古起源的异常现象。个别异常的考古研究证实了地球物理解释的可靠性,如预期的那样,热构造(窑、炉)和生活、生产壕深入到黄土母岩中。墓地的磁成像显示了大约8个局部异常,强度为1.5-4.5 nT。一些异常的挖掘显示了铁器时代早期的防空洞和两个罗马晚期的坟墓。然而,另外两个出土的坟墓没有引起磁场干扰。磁化率、自然剩余磁化率和铁磁相的其他依赖于浓度和粒度的参数的实验室测量,以及磁矿物学检查表明,在磁图上出现的坟墓坑几乎完全被腐殖质土壤物质重新填充。磁性模型证明,如果坟墓的磁化强度等于土壤腐殖质层的磁化强度,坟墓可以产生测量到的异常。因此,这些坟墓坑被打开,并逐渐被潮湿的土壤材料填满。特别是为碎屑残余物的形成创造了条件。在根据磁探结果恢复科马里夫遗址的空间结构时,有必要考虑到可能存在的纪念碑的多层结构、该地区的地貌特征(这些特征可能被误解为考古对象),以及在磁图上没有由非磁性材料建造的古建筑的重要例子和挖掘后立即填埋的坟墓坑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Magnetic prospecting and rock magnetic study of soils and archaeological objects on the Late Roman time sites near Komariv in Middle Transnistria
The paper presents the outcome of the magnetic survey at the settlement and cemetery of the production center of the 3rd—5th centuries, Komariv (Khotyn district, Chernivtsi region), which is located on the right bank of the Dniester. The settlement has about seventy anomalies that may have an archaeological origin. The archaeological study of individual anomalies has confirmed, as expected, the reliability of geophysical interpretation of thermal structures (kilns, furnaces) and living and production dugouts deepened into the loess parent rock. Magnetic imaging at the cemetery showed about eight tens of local anomalies with an intensity of 1.5—4.5 nT. Excavations of some anomalies revealed the Early Iron Age dugout and two Late Roman graves. However, the other two excavated graves did not cause disturbance of magnetic field. Laboratory measurements of magnetic susceptibility, natural remanent magnetization and other concentration-dependent and grain-size-dependent parameters of the ferromagnetic phase, as well as magnetic mineralogy examination have shown that grave pits, which appeared on a magnetic map, are refilled almost exclusively with humus soil material. Magnetic modeling proved graves can create measured anomalies if their magnetization is equal to the magnetization of the humus horizon of the soil. Thus, these grave pits were left open and gradually refilled with moist soil material. In particular, conditions have been created for the formation of detrital remanence. When restoring the spatial structure of Komariv sites based on magnetic prospecting results, it is necessary to take into account probable multilayered structure of monuments, geomorphological features of the area, which can be misinterpreted as archeological objects, and the fact that important examples of ancient architecture constructed of non-magnetic materials and grave pits refilled immediately after digging will be absent on magnetic maps.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Geofizicheskiy Zhurnal-Geophysical Journal
Geofizicheskiy Zhurnal-Geophysical Journal GEOCHEMISTRY & GEOPHYSICS-
自引率
60.00%
发文量
50
期刊最新文献
Electrical conductivity anomalies study New palaeomagnetic data for Palaeoproterozoic AMCG complexes of the Ukrainian Shield Depth structure of the Transcarpathian Depression (Ukrainian part) according to density modeling data Development of the methodology of energy and environmental safety of Ukraine based on own geothermics The effect of the mantle and core matter phase state on the course of geodynamic processes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1