椎板切除术侧块螺钉固定后不同颈椎曲度与脊髓后运动的关系及其对手术效果的影响

Zhi-yu Li, Jinhui Tian, Bingzhi Liu, Xiaodong Li
{"title":"椎板切除术侧块螺钉固定后不同颈椎曲度与脊髓后运动的关系及其对手术效果的影响","authors":"Zhi-yu Li, Jinhui Tian, Bingzhi Liu, Xiaodong Li","doi":"10.3760/CMA.J.ISSN.1008-6315.2020.01.007","DOIUrl":null,"url":null,"abstract":"Objective To investigate the relationship between cervical curvature (CC) and spinal drift distance after laminectomy with lateral mass screw fixation and the influence on the operative effect. Methods From October 2016 to December 2017, a total of 85 patients with cervical spondylotic myelopathy (CSM) underwent laminectomy with lateral mass screw fixation in handan central hospital, and 78 patients were followed up completely.After the operation, according to the Harrison method, they were divided into 2 groups(Group A (43 cases, 0°≤CC≤16.5°); Group B (35 cases, CC>16.5°)). The spinal drift distance, nerve recovery, axial symptoms and C5 palsy in the groups were recorded and analyzed. Results The CC was 8.5°±3.8° in group A and 19.6°±3.0° in group B (t=14.071, P=0.000). The laminectomy width in group A was (22.1±1.7) mm, in group B was (21.8±1.5) mm, the difference between the two groups was not statistically significant (P>0.05). The distance of spinal cord backward movement was (1.7±0.4) mm in group A and (3.2±0.7) mm in group B. There was significant difference between the two groups (t=11.879, P 0.05). Conclusion The greater the curvature of cervical spine is, the more fully the spinal cord moves backward.The loss of curvature of cervical spine is related to the occurrence of axial symptoms.The curvature of cervical spine is not related to the recovery of nerve function and the occurrence of C5 nerve paralysis. Key words: Lateral mass screw fixation; Cervical spondylotic myelopathy; C5 palsy; Axial symptoms","PeriodicalId":10365,"journal":{"name":"中国综合临床","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Relationship between different cervical curvature and spinal cord posterior movement after laminectomy with lateral mass screw fixation and its influence on the operative effect\",\"authors\":\"Zhi-yu Li, Jinhui Tian, Bingzhi Liu, Xiaodong Li\",\"doi\":\"10.3760/CMA.J.ISSN.1008-6315.2020.01.007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective To investigate the relationship between cervical curvature (CC) and spinal drift distance after laminectomy with lateral mass screw fixation and the influence on the operative effect. Methods From October 2016 to December 2017, a total of 85 patients with cervical spondylotic myelopathy (CSM) underwent laminectomy with lateral mass screw fixation in handan central hospital, and 78 patients were followed up completely.After the operation, according to the Harrison method, they were divided into 2 groups(Group A (43 cases, 0°≤CC≤16.5°); Group B (35 cases, CC>16.5°)). The spinal drift distance, nerve recovery, axial symptoms and C5 palsy in the groups were recorded and analyzed. Results The CC was 8.5°±3.8° in group A and 19.6°±3.0° in group B (t=14.071, P=0.000). The laminectomy width in group A was (22.1±1.7) mm, in group B was (21.8±1.5) mm, the difference between the two groups was not statistically significant (P>0.05). The distance of spinal cord backward movement was (1.7±0.4) mm in group A and (3.2±0.7) mm in group B. There was significant difference between the two groups (t=11.879, P 0.05). Conclusion The greater the curvature of cervical spine is, the more fully the spinal cord moves backward.The loss of curvature of cervical spine is related to the occurrence of axial symptoms.The curvature of cervical spine is not related to the recovery of nerve function and the occurrence of C5 nerve paralysis. Key words: Lateral mass screw fixation; Cervical spondylotic myelopathy; C5 palsy; Axial symptoms\",\"PeriodicalId\":10365,\"journal\":{\"name\":\"中国综合临床\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国综合临床\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.1008-6315.2020.01.007\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国综合临床","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1008-6315.2020.01.007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的探讨椎板切除术侧块螺钉固定后颈椎曲度与脊柱漂移距离的关系及对手术效果的影响。方法2016年10月至2017年12月在邯郸市中心医院行椎板切除术+侧块螺钉固定治疗的脊髓型颈椎病(CSM)患者85例,并对78例患者进行完全随访。术后按Harrison法分为2组(A组43例,0°≤CC≤16.5°);B组(35例,CC bb0 16.5°)。记录分析各组脊髓漂移距离、神经恢复情况、轴向症状及C5麻痹情况。结果A组CC为8.5°±3.8°,B组CC为19.6°±3.0°(t=14.071, P=0.000)。A组椎板切除宽度为(22.1±1.7)mm, B组为(21.8±1.5)mm,两组比较差异无统计学意义(P < 0.05)。脊髓向后运动距离A组为(1.7±0.4)mm, b组为(3.2±0.7)mm,两组比较差异有统计学意义(t=11.879, P < 0.05)。结论颈椎曲度越大,脊髓后移越充分。颈椎曲度的丧失与轴向症状的发生有关。颈椎曲度与神经功能恢复及C5神经麻痹的发生无关。关键词:侧块螺钉固定;脊髓型颈椎病;C5麻痹;轴向的症状
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Relationship between different cervical curvature and spinal cord posterior movement after laminectomy with lateral mass screw fixation and its influence on the operative effect
Objective To investigate the relationship between cervical curvature (CC) and spinal drift distance after laminectomy with lateral mass screw fixation and the influence on the operative effect. Methods From October 2016 to December 2017, a total of 85 patients with cervical spondylotic myelopathy (CSM) underwent laminectomy with lateral mass screw fixation in handan central hospital, and 78 patients were followed up completely.After the operation, according to the Harrison method, they were divided into 2 groups(Group A (43 cases, 0°≤CC≤16.5°); Group B (35 cases, CC>16.5°)). The spinal drift distance, nerve recovery, axial symptoms and C5 palsy in the groups were recorded and analyzed. Results The CC was 8.5°±3.8° in group A and 19.6°±3.0° in group B (t=14.071, P=0.000). The laminectomy width in group A was (22.1±1.7) mm, in group B was (21.8±1.5) mm, the difference between the two groups was not statistically significant (P>0.05). The distance of spinal cord backward movement was (1.7±0.4) mm in group A and (3.2±0.7) mm in group B. There was significant difference between the two groups (t=11.879, P 0.05). Conclusion The greater the curvature of cervical spine is, the more fully the spinal cord moves backward.The loss of curvature of cervical spine is related to the occurrence of axial symptoms.The curvature of cervical spine is not related to the recovery of nerve function and the occurrence of C5 nerve paralysis. Key words: Lateral mass screw fixation; Cervical spondylotic myelopathy; C5 palsy; Axial symptoms
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
16855
期刊介绍: Clinical Medicine of China is an academic journal organized by the Chinese Medical Association (CMA), which mainly publishes original research papers, reviews and commentaries in the field. Clinical Medicine of China is a source journal of Peking University (2000 and 2004 editions), a core journal of Chinese science and technology, an academic journal of RCCSE China Core (Extended Edition), and has been published in Chemical Abstracts of the United States (CA), Abstracts Journal of Russia (AJ), Chinese Core Journals (Selection) Database, Chinese Science and Technology Materials Directory, Wanfang Database, China Academic Journal Database, JST Japan Science and Technology Agency Database (Japanese) (2018) and other databases.
期刊最新文献
Comparison of the efficacy of midcaudal combined approach and cephalic middle approach in laparoscopic complete mesocolic excision for right hemicolon cancer with incomplete ileus The clinical advantage of nano carbon suspension mapping in the number of axillary lymph nodes detected after neoadjuvant chemotherapy for breast cancer Correlation of serum monokine induced by IFN-γ and interleukin9 to HBV pre-C/BCP mutation and their influences on the response to interferon therapy in patients with HBeAg-positive chronic hepatitis B Study on the relationship between Plasma Pro amino terminal brain natriuretic peptide, left ventricular mass index and the prognosis in elderly heart failure patients with preserved ejection fraction Clinical analysis of 16 cases of remedial stent placement after mechanical thrombectomy for acute cerebral infarction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1