{"title":"方波脉冲诱发的光性癫痫。通过改变刺激强度和持续时间研究一例报告。","authors":"Y. Honda","doi":"10.3928/0191-3913-19770901-14","DOIUrl":null,"url":null,"abstract":"A spike and wave discharge of photic-evoked myoclonic epilepsy was investigated employing square-wave pulses of a stimulator having mechanical shutter, and the following conclusions were reached. The amplitude of the spike and wave complex of photogenic epilepsy depends on the intensity of photic stimulation when this is investigated in the range from 2.5 X 10(3) ergs/cm2 sec to its 4.31 log units high. A spike prior to the slow wave appears as the stimulus intensity increases. The implicit time is shortened as the intensity increases. Prolongation of the stimulus duration makes the ascending phase of the slow wave steep, and an off-response appeared when stimuli of 100 msec or longer were applied. Clinically, a biphasic myoclonic convulsion of limbs is clearly observed in on- and off-phases when stimuli of 300 msec or longer are applied. The responses become prominent when frequency increases from 0.5 to 3.0/sec.","PeriodicalId":76019,"journal":{"name":"Journal of pediatric ophthalmology","volume":"14 5 1","pages":"309-15"},"PeriodicalIF":0.0000,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Photic epilepsy evoked by square-wave pulses. Report of a case studied by changing stimulus intensity and duration.\",\"authors\":\"Y. Honda\",\"doi\":\"10.3928/0191-3913-19770901-14\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A spike and wave discharge of photic-evoked myoclonic epilepsy was investigated employing square-wave pulses of a stimulator having mechanical shutter, and the following conclusions were reached. The amplitude of the spike and wave complex of photogenic epilepsy depends on the intensity of photic stimulation when this is investigated in the range from 2.5 X 10(3) ergs/cm2 sec to its 4.31 log units high. A spike prior to the slow wave appears as the stimulus intensity increases. The implicit time is shortened as the intensity increases. Prolongation of the stimulus duration makes the ascending phase of the slow wave steep, and an off-response appeared when stimuli of 100 msec or longer were applied. Clinically, a biphasic myoclonic convulsion of limbs is clearly observed in on- and off-phases when stimuli of 300 msec or longer are applied. The responses become prominent when frequency increases from 0.5 to 3.0/sec.\",\"PeriodicalId\":76019,\"journal\":{\"name\":\"Journal of pediatric ophthalmology\",\"volume\":\"14 5 1\",\"pages\":\"309-15\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1977-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of pediatric ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3928/0191-3913-19770901-14\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pediatric ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3928/0191-3913-19770901-14","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
采用带机械快门的刺激器的方波脉冲对光诱发肌阵挛性癫痫的尖峰和波放电进行了研究,得出了以下结论。光致性癫痫的峰和波复合体的振幅取决于光刺激的强度,在2.5 X 10(3) ergs/cm2秒到4.31 log单位高的范围内进行研究。随着刺激强度的增加,在慢波之前出现一个尖峰。隐式时间随强度的增加而缩短。刺激持续时间的延长使慢波上升相位陡变,当刺激时间在100毫秒或更长时,慢波出现断反应。临床上,当施加300毫秒或更长时间的刺激时,可以清楚地观察到两相性四肢肌阵挛性抽搐。当频率从0.5 /秒增加到3.0/秒时,响应变得突出。
Photic epilepsy evoked by square-wave pulses. Report of a case studied by changing stimulus intensity and duration.
A spike and wave discharge of photic-evoked myoclonic epilepsy was investigated employing square-wave pulses of a stimulator having mechanical shutter, and the following conclusions were reached. The amplitude of the spike and wave complex of photogenic epilepsy depends on the intensity of photic stimulation when this is investigated in the range from 2.5 X 10(3) ergs/cm2 sec to its 4.31 log units high. A spike prior to the slow wave appears as the stimulus intensity increases. The implicit time is shortened as the intensity increases. Prolongation of the stimulus duration makes the ascending phase of the slow wave steep, and an off-response appeared when stimuli of 100 msec or longer were applied. Clinically, a biphasic myoclonic convulsion of limbs is clearly observed in on- and off-phases when stimuli of 300 msec or longer are applied. The responses become prominent when frequency increases from 0.5 to 3.0/sec.